Passive neutron area monitor with pairs of TLDs as neutron detector

被引:18
|
作者
Rene Vega-Carrillo, Hector [1 ]
Arlete Guzman-Garcia, Karen [2 ]
Gallego, Eduardo [2 ]
Lorente, Alfredo [2 ]
机构
[1] Univ Autonoma Zacatecas, Unidad Acad Estudios Nucl, Zacatecas 98068, Zac, Mexico
[2] Univ Politecn Madrid, Dept Ingn Nucl, E-28006 Madrid, Spain
关键词
Neutron; Ambient dose equivalent; Neutron area monitor; Passive; TLD600; TLD700; BONNER SPHERE SPECTROMETER; RESPONSE MATRIX; SPECTRA; FIELD;
D O I
10.1016/j.radmeas.2014.08.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A passive neutron area monitor has been designed using Monte Carlo methods; the monitor is a polyethylene cylinder with pairs of thermoluminescent dosimeters (TLD600 and TLD700) as thermal neutron detector. The monitor was calibrated with a bare and a thermalzed (AmBe)-Am-241 neutron sources and its performance was evaluated measuring the ambient dose equivalent due to photoneutrons produced by a 15 MV linear accelerator for radiotherapy and the neutrons in the output of a TRIGA Mark III radial beam port. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:30 / 34
页数:5
相关论文
共 50 条
  • [1] Neutron area monitor with passive detector
    Valero-Luna, C.
    Guzman-Garcia, K. A.
    Borja-Hernandez, C. G.
    Hernandez-Davila, V. M.
    Vega-Carrillo, H. R.
    REVISTA MEXICANA DE FISICA, 2012, 58 (03) : 262 - 264
  • [2] Passive neutron area monitor with TLD pairs
    Guzman-Garcia, K. A.
    Borja-Hernandez, C. G.
    Valero-Luna, C.
    Hernandez-Davila, V. M.
    Vega-Carrillo, H. R.
    REVISTA MEXICANA DE FISICA, 2012, 58 (03) : 220 - 223
  • [3] CubBonner - A novel passive neutron area monitor
    Baltazar-Raigosa, Antonio
    Gabriela Soto-Bernal, Tzinnia
    Rene Vega-Carrillo, Hector
    Garcia-Duran, Angel
    Oliva Torres-Cortes, Carina
    Galvan-Tejada, Jorge, I
    Gamboa-Rosales, Hamurabi
    APPLIED RADIATION AND ISOTOPES, 2020, 161
  • [4] Passive neutron area monitor with CR39
    Vega-Carrillo, H. R.
    Barquero, R.
    Mercado, G. A.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2013, 11 (03): : 149 - 153
  • [5] A novel neutron area-monitor based on the bubble detector
    Ing, H
    Noulty, RA
    Clifford, ETH
    Gamero, JS
    Cameron, DR
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 101 - 104
  • [6] ENERGY RESPONSE OF NEUTRON AREA MONITOR WITH SILICON SEMICONDUCTOR DETECTOR
    KITAGUCHI, H
    IZUMI, S
    KOBAYASHI, K
    KAIHARA, A
    NAKAMURA, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1993, 30 (12) : 1283 - 1287
  • [7] Evaluation of imaging plate technique coupled with activation detector as the passive neutron monitor
    K. Masumoto
    K. Iijima
    A. Toyoda
    Q. Wang
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 271 : 297 - 303
  • [8] Evaluation of imaging plate technique coupled with activation detector as the passive neutron monitor
    Masumoto, K.
    Iijima, K.
    Toyoda, A.
    Wang, Q.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 271 (02) : 297 - 303
  • [9] Investigation into the Neutron Detector for a Radiation Monitor
    Luzhanchuk, Ya, V
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2022, 65 (03) : 382 - 385
  • [10] Investigation into the Neutron Detector for a Radiation Monitor
    Ya. V. Luzhanchuk
    Instruments and Experimental Techniques, 2022, 65 : 382 - 385