Development of a Data-Independent Targeted Metabolomics Method for Relative Quantification Using Liquid Chromatography Coupled with Tandem Mass Spectrometry

被引:57
|
作者
Chen, Yanhua [1 ,2 ]
Zhou, Zhi [1 ,2 ]
Yang, Wei [1 ,2 ,7 ]
Bi, Nan [3 ,4 ,5 ]
Xu, Jing [1 ,2 ]
He, Jiuming [1 ,2 ]
Zhang, Ruiping [1 ,2 ]
Wang, Lvhua [3 ,4 ,5 ]
Abliz, Zeper [1 ,2 ,6 ]
机构
[1] Chinese Acad Med Sci, Inst Mat Med, State Key Lab Bioact Subst & Funct Nat Med, Beijing 100050, Peoples R China
[2] Peking Union Med Coll, Beijing 100050, Peoples R China
[3] Chinese Acad Med Sci, Canc Inst, Beijing 100021, Peoples R China
[4] Chinese Acad Med Sci, Canc Hosp, Beijing 100021, Peoples R China
[5] Peking Union Med Coll, Beijing 100021, Peoples R China
[6] Minzu Univ China, Ctr Bioimaging & Syst Biol, Beijing 100081, Peoples R China
[7] China Acad Chinese Med Sci, Inst Chinese Mat Med, Ctr DMPK Res Herbal Med, Beijing 100700, Peoples R China
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
METABOLITES; RESPONSES;
D O I
10.1021/acs.analchem.6b04727
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative metabolomics approaches can significantly improve the repeatability and reliability of metabolomics investigations but face critical technical challenges, owing to the vast number of unknown endogenous metabolites and the lack of authentic standards. The present study contributes to the development of a novel method known as "data-independent targeted quantitative metabolomics" (DITQM), which was used to investigate the label-free quantitative metabolomics of multiple known and unknown metabolites in biofluid samples. This approach initially involved the acquisition of MS/MS data for all metabolites in biosamples using a sequentially stepped targeted MS/MS (sst-MS/MS) method; in which multiple product ion scans were performed by selecting all ions, in the targeted mass ranges as the precursor ions. Subsequently, scheduled multiple reaction monitoring: (MRM) by LC-MS/MS of the metabolome was established for 1658 characteristic ion pairs. of 1324 Metabolites. For sensitive and accurate quantification of these metabolites, mixed calibration curves were generated using sequentially diluted standard reference plasma samples using established MRM methods. Relative concentrations of all metabolites in each sample were calculated without using individual authentic standards. To evaluate the reliability and applicability of this new method, the performance of DITQM was validated by comparison to absolute quantification of 12 acylcarnitines using authentic standards and traditional metabolomics analysis for lung cancer. The results proved that the DITQM protocol is more reliable and can significantly improve clustering effects and repeatability in biomarker discovery. In. this study, we established a novel methodology to standardize and quantify-large-scale metabolome, providing a new choice for metabolomics research and its clinical applications.
引用
收藏
页码:6954 / 6962
页数:9
相关论文
共 50 条
  • [21] Differential quantification of isobaric phosphopeptides using data-independent acquisition mass spectrometry
    Sidoli, Simone
    Fujiwara, Rina
    Kulej, Katarzyna
    Garcia, Benjamin A.
    MOLECULAR BIOSYSTEMS, 2016, 12 (08) : 2385 - 2388
  • [22] Targeted phosphoproteomics of insulin signaling using data-independent acquisition mass spectrometry
    Parker, Benjamin L.
    Yang, Guang
    Humphrey, Sean J.
    Chaudhuri, Rima
    Ma, Xiuquan
    Peterman, Scott
    James, David E.
    SCIENCE SIGNALING, 2015, 8 (380)
  • [23] Development of a method for crustacean allergens using liquid chromatography/tandem mass spectrometry
    Nagai, Hiroyuki (nagai-hiroyuki@pref.gifu.lg.jp), 1600, AOAC International (98):
  • [24] Development of a Method for Crustacean Allergens Using Liquid Chromatography/Tandem Mass Spectrometry
    Nagai, Hiroyuki
    Minatani, Tomiaki
    Goto, Kotaro
    JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (05) : 1355 - 1365
  • [25] Development and validation of a fast and reliable method for the quantification of glucagon by liquid chromatography and tandem mass spectrometry
    Farre-Segura, Jordi
    Fabregat-Cabello, Neus
    Calaprice, Chiara
    Nyssen, Laurent
    Peeters, Stephanie
    Le Goff, Caroline
    Cavalier, Etienne
    CLINICA CHIMICA ACTA, 2021, 512 : 156 - 165
  • [26] Quantification of Fluoxetine in Human Plasma by the Development of Liquid Chromatography-tandem Mass Spectrometry Method
    Negi, Geeta
    Majeed, Jaseela
    Arora, Saurabh
    Rana, Sachin
    Singh, Manoj
    Tomar, Jaideep
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2021, 55 (01) : S303 - S311
  • [27] Metabolomic spectral libraries for data-independent SWATH liquid chromatography mass spectrometry acquisition
    Tobias Bruderer
    Emmanuel Varesio
    Anita O. Hidasi
    Eva Duchoslav
    Lyle Burton
    Ron Bonner
    Gérard Hopfgartner
    Analytical and Bioanalytical Chemistry, 2018, 410 : 1873 - 1884
  • [28] Metabolomic spectral libraries for data-independent SWATH liquid chromatography mass spectrometry acquisition
    Bruderer, Tobias
    Varesio, Emmanuel
    Hidasi, Anita O.
    Duchoslav, Eva
    Burton, Lyle
    Bonner, Ron
    Hopfgartner, Gerard
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (07) : 1873 - 1884
  • [29] Development and Validation of a Simultaneous Quantification Method of Ruxolitinib, Vismodegib, Olaparib, and Pazopanib in Human Plasma Using Liquid Chromatography Coupled With Tandem Mass Spectrometry
    Pressiat, Claire
    Huynh, Huu-Hien
    Ple, Alain
    Sauvageon, Helene
    Madelaine, Isabelle
    Chougnet, Cecile
    Le Maignan, Christine
    Mourah, Samia
    Goldwirt, Lauriane
    THERAPEUTIC DRUG MONITORING, 2018, 40 (03) : 337 - 343
  • [30] Development and Validation of a Method of Liquid Chromatography Coupled with Tandem Mass Spectrometry for Quantification of ST-246 (Tecovirimat) in Human Plasma
    Oleinik, Galina A.
    Koval, Vladimir V.
    Usova, Svetlana, V
    Shishkina, Larisa N.
    Chernonosov, Alexander A.
    MOLECULES, 2022, 27 (11):