Development of a Data-Independent Targeted Metabolomics Method for Relative Quantification Using Liquid Chromatography Coupled with Tandem Mass Spectrometry

被引:57
|
作者
Chen, Yanhua [1 ,2 ]
Zhou, Zhi [1 ,2 ]
Yang, Wei [1 ,2 ,7 ]
Bi, Nan [3 ,4 ,5 ]
Xu, Jing [1 ,2 ]
He, Jiuming [1 ,2 ]
Zhang, Ruiping [1 ,2 ]
Wang, Lvhua [3 ,4 ,5 ]
Abliz, Zeper [1 ,2 ,6 ]
机构
[1] Chinese Acad Med Sci, Inst Mat Med, State Key Lab Bioact Subst & Funct Nat Med, Beijing 100050, Peoples R China
[2] Peking Union Med Coll, Beijing 100050, Peoples R China
[3] Chinese Acad Med Sci, Canc Inst, Beijing 100021, Peoples R China
[4] Chinese Acad Med Sci, Canc Hosp, Beijing 100021, Peoples R China
[5] Peking Union Med Coll, Beijing 100021, Peoples R China
[6] Minzu Univ China, Ctr Bioimaging & Syst Biol, Beijing 100081, Peoples R China
[7] China Acad Chinese Med Sci, Inst Chinese Mat Med, Ctr DMPK Res Herbal Med, Beijing 100700, Peoples R China
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
METABOLITES; RESPONSES;
D O I
10.1021/acs.analchem.6b04727
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative metabolomics approaches can significantly improve the repeatability and reliability of metabolomics investigations but face critical technical challenges, owing to the vast number of unknown endogenous metabolites and the lack of authentic standards. The present study contributes to the development of a novel method known as "data-independent targeted quantitative metabolomics" (DITQM), which was used to investigate the label-free quantitative metabolomics of multiple known and unknown metabolites in biofluid samples. This approach initially involved the acquisition of MS/MS data for all metabolites in biosamples using a sequentially stepped targeted MS/MS (sst-MS/MS) method; in which multiple product ion scans were performed by selecting all ions, in the targeted mass ranges as the precursor ions. Subsequently, scheduled multiple reaction monitoring: (MRM) by LC-MS/MS of the metabolome was established for 1658 characteristic ion pairs. of 1324 Metabolites. For sensitive and accurate quantification of these metabolites, mixed calibration curves were generated using sequentially diluted standard reference plasma samples using established MRM methods. Relative concentrations of all metabolites in each sample were calculated without using individual authentic standards. To evaluate the reliability and applicability of this new method, the performance of DITQM was validated by comparison to absolute quantification of 12 acylcarnitines using authentic standards and traditional metabolomics analysis for lung cancer. The results proved that the DITQM protocol is more reliable and can significantly improve clustering effects and repeatability in biomarker discovery. In. this study, we established a novel methodology to standardize and quantify-large-scale metabolome, providing a new choice for metabolomics research and its clinical applications.
引用
收藏
页码:6954 / 6962
页数:9
相关论文
共 50 条
  • [1] Targeted Data-Independent Acquisition and Mining Strategy for Trace Drug Metabolite Identification Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
    Gao, Yan
    Zhang, Ruiping
    Bai, Jinfa
    Xia, Xuejun
    Chen, Yanhua
    Luo, Zhigang
    Xu, Jing
    Gao, Yang
    Liu, Yuling
    He, Jiuming
    Abliz, Zeper
    ANALYTICAL CHEMISTRY, 2015, 87 (15) : 7535 - 7539
  • [2] Development of simultaneous targeted metabolite quantification and untargeted metabolomics strategy using dual-column liquid chromatography coupled with tandem mass spectrometry
    Gao, Yang
    Chen, Yanhua
    Yue, Xiaofei
    He, Jiuming
    Zhang, Ruiping
    Xu, Jing
    Zhou, Zhi
    Wang, Zhonghua
    Zhang, Rui
    Abliz, Zeper
    ANALYTICA CHIMICA ACTA, 2018, 1037 : 369 - 379
  • [3] Targeted metabolomics in human and animal biofluids and tissues using liquid chromatography coupled with tandem mass spectrometry
    Willency, Jill A.
    Lin, Yanzhu
    Pirro, Valentina
    STAR PROTOCOLS, 2024, 5 (01):
  • [4] Liquid chromatography and differential mobility spectrometry—data-independent mass spectrometry for comprehensive multidimensional separations in metabolomics
    Lysi Ekmekciu
    Gérard Hopfgartner
    Analytical and Bioanalytical Chemistry, 2023, 415 : 1905 - 1915
  • [5] New targeted approaches for the quantification of data-independent acquisition mass spectrometry
    Bruderer, Roland
    Sondermann, Julia
    Tsou, Chih-Chiang
    Barrantes-Freer, Alonso
    Stadelmann, Christine
    Nesvizhskii, Alexey I.
    Schmidt, Manuela
    Reiter, Lukas
    Gomez-Varela, David
    PROTEOMICS, 2017, 17 (09)
  • [6] Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
    Mohammad, Karamat
    Jiang, Heng
    Titorenko, Vladimir, I
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (167): : 1 - 28
  • [7] Targeted Metabolomics of the Phenylpropanoid Pathway in Arabidopsis thaliana using Reversed Phase Liquid Chromatography Coupled with Tandem Mass Spectrometry
    Jaini, Rohit
    Wang, Peng
    Dudareva, Natalia
    Chapple, Clint
    Morgan, John A.
    PHYTOCHEMICAL ANALYSIS, 2017, 28 (04) : 267 - 276
  • [8] Regions of Interest Multivariate Curve Resolution Liquid Chromatography with Data-Independent Acquisition Tandem Mass Spectrometry
    Perez-Lopez, Carlos
    Oro-Noll, Bernat
    Lacorte, Silvia
    Tauler, Roma
    ANALYTICAL CHEMISTRY, 2023, 95 (19) : 7519 - 7527
  • [9] Development of a metabolic pathway-based pseudo-targeted metabolomics method using liquid chromatography coupled with mass spectrometry
    Xu, Jing
    Li, Jiangshuo
    Zhang, Ruiping
    He, Jiuming
    Chen, Yanhua
    Bi, Nan
    Song, Yongmei
    Wang, Luhua
    Zhan, Qimin
    Abliz, Zeper
    TALANTA, 2019, 192 : 160 - 168
  • [10] Advancing Targeted Metabolomics Using Cyanopropyl-Based Liquid Chromatography Tandem Mass Spectrometry
    Liao, Wan-Rou
    Lin, Jiun-Tsai
    Lin, Pei-Chen
    Chen, Chin-Chen
    Huang, Chun-Fang
    Chen, Han-Min
    Chen, Sung-Fang
    ANALYTICAL CHEMISTRY, 2024, 96 (47) : 18625 - 18634