Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver

被引:50
|
作者
Aykan, Umit [1 ]
Erdurmus, Mesut [1 ]
Yilmaz, Burhan [1 ]
Bilge, Ahmet Hamdi [1 ]
机构
[1] GATA Haydarpasa Training Hosp, Dept Ophthalmol, Istanbul, Turkey
关键词
Valsalva maneuver; Pascal dynamic contour tonometer; Intraocular pressure; Ocular pulse amplitude; DYNAMIC CONTOUR TONOMETRY; GOLDMANN APPLANATION TONOMETRY; NORMAL-TENSION GLAUCOMA; VISUAL-FIELD DEFECTS; CORNEAL THICKNESS; BLOOD-FLOW; OPEN-ANGLE; PNEUMATONOMETER; HYPERTENSION; CURVATURE;
D O I
10.1007/s00417-010-1359-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the effect of the Valsalva maneuver (VM) on short-term variations of intraocular pressure (IOP) and ocular pulse amplitude (OPA) values in healthy, young, male subjects. IOP and OPA values were measured before and during VM by Pascal dynamic contour tonometer (DCT) in 55 eyes of 55 healthy male volunteers aged 20 through 27 years. Mean IOP before VM was 17.2 +/- 2.9 mmHg and during the VM was 19.8 +/- 4 mmHg. The increase in mean IOP during the VM was found to be statistically significant (p = 0.001). The IOP increased in 46 (83.6%) of 55 eyes. However, in nine eyes (16.4%), IOP decreased during the VM. Mean OPA value before VM was 3.6 +/- 1.4 mmHg and during the VM was 3.6 +/- 1.3 mmHg. The change in mean OPA value was found to be statistically insignificant (p = 0.9). The IOP significantly increases during VM, whereas OPA remains stable. Strong autoregulatory mechanisms may provide consistent ocular perfusion in healthy subjects during VM.
引用
收藏
页码:1183 / 1186
页数:4
相关论文
共 50 条
  • [31] SUPRAGLOTTAL AIR-PRESSURE DURING A VALSALVA MANEUVER
    BROWN, WS
    MCGLONE, RE
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1979, 65 : S26 - S26
  • [32] Pulse Amplitude Ratio Measured Using Finger Photoplethysmography During a Valsalva Maneuver Estimates Pulmonary Capillary Wedge Pressure in Heart Failure Patients
    Gilotra, Nisha A.
    Tedford, Ryan J.
    Wittstein, Ilan S.
    Russell, Stuart D.
    Silber, Harry A.
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (08) : S18 - S18
  • [33] PRESSURE-FLOW STUDIES DURING VALSALVA MANEUVER
    SCHOONMA.FW
    COX, RL
    HERNANDE.R
    GREENFIE.JC
    CIRCULATION, 1966, 34 (4S3) : I210 - &
  • [34] Value of Plethysmographic Pulse Amplitude Ratio With Valsalva Maneuver in Identifying Left Ventricular Dysfunction During COPD Exacerbation
    Boubaker, Hamdi
    Grissa, Mohamed Habib
    Debbabi, Haithem
    Beltaief, Kaouthar
    Dridi, Zohra
    Najjar, Mohamed Fadhel
    Bouida, Wahid
    Boukef, Riadh
    Marghli, Soudani
    Nouira, Semir
    RESPIRATORY CARE, 2016, 61 (04) : 439 - 446
  • [35] Studies on behaviour of venous pressure during the Valsalva maneuver
    Liedholm, K
    ACTA MEDICA SCANDINAVICA, 1939, : COVER1 - 213
  • [36] Ocular rigidity as estimated based on measurement of pulse amplitude using pneumotonometry and fundus pulse is dependent on intraocular pressure
    Hommer, Anton
    Garhofer, Gerhard
    Schmetterer, Leopold
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [37] Valsalva Maneuver, Intraocular Pressure, Cerebrospinal Fluid Pressure, and Optic Disc Topography: Beijing Intracranial and Intraocular Pressure (iCOP) Study
    Wang, Ningli
    Zhang, Zheng
    Jonas, Jost
    Ritch, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [38] ARTERIAL PRESSURE PULSE CONTOUR AND VALSALVA MANEUVER IN SUSPECTED AORTIC STENOSIS
    ROSENBERG, SZ
    BRAUN, K
    STERN, S
    AMERICAN HEART JOURNAL, 1958, 56 (04) : 486 - 492
  • [39] Effect of sub-Tenon's and peribulbar anesthesia on intraocular pressure and ocular pulse amplitude
    Pianka, P
    Weintraub-Padova, H
    Lazar, M
    Geyer, O
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (08): : 1221 - 1226
  • [40] Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
    Hoffmann E.M.
    Grus F.-H.
    Pfeiffer N.
    BMC Ophthalmology, 4 (1) : 1 - 7