Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver

被引:50
|
作者
Aykan, Umit [1 ]
Erdurmus, Mesut [1 ]
Yilmaz, Burhan [1 ]
Bilge, Ahmet Hamdi [1 ]
机构
[1] GATA Haydarpasa Training Hosp, Dept Ophthalmol, Istanbul, Turkey
关键词
Valsalva maneuver; Pascal dynamic contour tonometer; Intraocular pressure; Ocular pulse amplitude; DYNAMIC CONTOUR TONOMETRY; GOLDMANN APPLANATION TONOMETRY; NORMAL-TENSION GLAUCOMA; VISUAL-FIELD DEFECTS; CORNEAL THICKNESS; BLOOD-FLOW; OPEN-ANGLE; PNEUMATONOMETER; HYPERTENSION; CURVATURE;
D O I
10.1007/s00417-010-1359-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the effect of the Valsalva maneuver (VM) on short-term variations of intraocular pressure (IOP) and ocular pulse amplitude (OPA) values in healthy, young, male subjects. IOP and OPA values were measured before and during VM by Pascal dynamic contour tonometer (DCT) in 55 eyes of 55 healthy male volunteers aged 20 through 27 years. Mean IOP before VM was 17.2 +/- 2.9 mmHg and during the VM was 19.8 +/- 4 mmHg. The increase in mean IOP during the VM was found to be statistically significant (p = 0.001). The IOP increased in 46 (83.6%) of 55 eyes. However, in nine eyes (16.4%), IOP decreased during the VM. Mean OPA value before VM was 3.6 +/- 1.4 mmHg and during the VM was 3.6 +/- 1.3 mmHg. The change in mean OPA value was found to be statistically insignificant (p = 0.9). The IOP significantly increases during VM, whereas OPA remains stable. Strong autoregulatory mechanisms may provide consistent ocular perfusion in healthy subjects during VM.
引用
收藏
页码:1183 / 1186
页数:4
相关论文
共 50 条
  • [1] Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver
    Umit Aykan
    Mesut Erdurmus
    Burhan Yilmaz
    Ahmet Hamdi Bilge
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1183 - 1186
  • [2] On variations of the blood amplitude and the pulse volume during respiration and under valsalva maneuver.
    Hauss, W
    PFLUGERS ARCHIV FUR DIE GESAMTE PHYSIOLOGIE DES MENSCHEN UND DER TIERE, 1938, 240 (06): : 653 - 660
  • [3] MEASUREMENT OF INTRAOCULAR-PRESSURE DURING A VALSALVA MANEUVER AND RELATION TO OCULAR POSTOPERATIVE WOUND FAILURE
    BODENDORFER, KD
    ROSENWASSER, GOD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S1005 - S1005
  • [4] Reduction of intraocular pressure and ocular pulse amplitude during general anesthesia
    Zuche, H. H.
    Morinello, E.
    Viestenz, A.
    Fiorentzis, M.
    Seitz, B.
    Volk, T.
    Viestenz, A.
    OPHTHALMOLOGE, 2015, 112 (09): : 764 - 769
  • [5] OCULAR PRESSURE PATTERNS IN THE VALSALVA MANEUVER
    ROSEN, DA
    JOHNSTON, VC
    ARCHIVES OF OPHTHALMOLOGY, 1959, 62 (05) : 810 - 816
  • [6] Changes in intraocular pressure and ocular pulse amplitude with accommodation
    Read, Scott A.
    Collins, Michael J.
    Becker, Heidi
    Cutting, Jeremy
    Ross, Danielle
    Savill, Annyck K.
    Trevor, Beth
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (03) : 332 - 335
  • [7] The ocular pulse amplitude at different intraocular pressure: a prospective study
    Knecht, Pascal Bruno
    Bosch, Martina Monika
    Michels, Stephan
    Mannhardt, Soenke
    Schmid, Ursina
    Bosch, Martin Albert
    Menke, Marcel Nico
    ACTA OPHTHALMOLOGICA, 2011, 89 (05) : E466 - E471
  • [8] Effects of childhood obesity on ocular pulse amplitude and intraocular pressure
    Bolu, Semih
    Direkci, Ilke
    Asik, Abdulvahit
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2023, 86 (02) : 121 - 126
  • [9] During the Valsalva Maneuver the Retinal Venous Pressure Is Higher than the Airway Pressure and the Intraocular Pressure
    Stodtmeister, Richard P.
    Heyde, Maria
    Ventzke, Sylvana
    Spoerl, Eberhard
    Pillunat, Lutz E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [10] Effects of Swimming Goggles Wearing on Intraocular Pressure, Ocular Perfusion Pressure, and Ocular Pulse Amplitude
    Paula, Ana P. B.
    Paula, Jayter S.
    Silva, Marcelo J. L.
    Rocha, Eduardo M.
    De Moraes, Carlos G.
    Rodrigues, Maria L. V.
    JOURNAL OF GLAUCOMA, 2016, 25 (10) : 860 - 864