Non-Newtonian effects of blood on LDL transport inside the arterial lumen and across multi-layered arterial wall with and without stenosis

被引:3
|
作者
Deyranlou, Amin [1 ,2 ]
Niazmand, Hamid [1 ,2 ]
Sadeghi, Mahmood-Reza [3 ]
Mesri, Yaser [1 ,2 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad, Iran
[2] Ferdowsi Univ Mashhad, Biomed Engn Res Ctr, Mashhad, Iran
[3] Univ Isfahan, Dept Biomed Engn, Esfahan, Iran
来源
关键词
Fluid-multilayered artery; low-density lipoprotein; non-Newtonian fluid; stenosis; LOW-DENSITY-LIPOPROTEIN; CANINE CAROTID ARTERIES; NUMERICAL-SIMULATION; CONCENTRATION POLARIZATION; MASS-TRANSFER; MACROMOLECULAR TRANSPORT; SHEAR-STRESS; FLOW; MODEL; PRESSURE;
D O I
10.1142/S0129183116500030
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Blood non-Newtonian behavior on low-density lipoproteins (LDL) accumulation is analyzed numerically, while fluid-multilayered arteries are adopted for nonstenotic and 30%-60% symmetrical stenosed models. Present model considers non-Newtonian effects inside the lumen and within arterial layers simultaneously, which has not been examined in previous studies. Navier-Stokes equations are solved along with the mass transport convection-diffusion equations and Darcy's model for species transport inside the luminal flow and across wall layers, respectively. Carreau model for the luminal flow and the modified Darcy equation for the power-law fluid within arterial layers are employed to model blood rheological characteristics, appropriately. Results indicate that in large arteries with relatively high Reynolds number Newtonian model estimates LDL concentration patterns well enough, however, this model seriously incompetent for regions with low WSS. Moreover, Newtonian model for plasma underestimates LDL concentration especially on luminal surface and across arterial wall. Therefore, applying non-Newtonian model seems essential for reaching to a more accurate estimation of LDL distribution in the artery. Finally, blood flow inside constricted arteries demonstrates that LDL concentration patterns along the stenoses inside the luminal flow and across arterial layers are strongly influenced as compared to the nonstenotic arteries. Additionally, among four stenosis severity grades, 40% stenosis is prone to more LDL accumulation along the post-stenotic regions.
引用
收藏
页数:22
相关论文
共 38 条
  • [31] EFFECTS OF THE NON-NEWTONIAN VISCOSITY OF BLOOD ON FLOWS IN A DISEASED ARTERIAL VESSEL .1. STEADY FLOWS
    CHO, YI
    KENSEY, KR
    BIORHEOLOGY, 1991, 28 (3-4) : 241 - 262
  • [32] Effect of the fluid-structure interactions on low-density lipoprotein transport within a multi-layered arterial wall
    Chung, Stephen
    Vafai, Kambiz
    JOURNAL OF BIOMECHANICS, 2012, 45 (02) : 371 - 381
  • [33] Modeling and numerical simulation of non-Newtonian arterial blood flow for mild to severe stenosis (vol 72, pg 195, 2023)
    Nadeem, Sohail
    Ali, Shahbaz
    Akkurt, Nevzat
    Hamida, Mohamed Bechir Ben
    Almutairi, Shahah
    Ghazwani, Hassan Ali
    Eldin, Sayed M.
    Khan, Zareen A.
    Al-Shafay, A. S.
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 78 : 306 - 306
  • [34] Non-Newtonian pulsatile blood flow through the stenosed arteries: comparison between the viscoelastic and elastic arterial wall in response to the alterations
    Jannati, Sahel
    Shahri, Mohammad Nabizadeh
    Jafarzadeh, Nahid
    Firouzi, Faramarz
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)
  • [35] A study on two-layered model (Casson-Newtonian) for blood flow through an arterial stenosis: Axially variable slip velocity at the wall
    Ponalagusamy, R.
    Selvi, R. Tamil
    JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2011, 348 (09): : 2308 - 2321
  • [36] Compliant model of a coupled sequential coronary arterial bypass graft: Effects of vessel wall elasticity and non-Newtonian rheology on blood flow regime and hemodynamic parameters distribution
    Kabinejadian, Foad
    Ghista, Dhanjoo N.
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (07) : 860 - 872
  • [37] Blood flow through an arterial stenosis: A two-layered model (Casson-Newtonian), different shapes of stenoses and axially variable slip velocity at the wall
    Ponalagusamy, R.
    BIORHEOLOGY, 2008, 45 (1-2) : 153 - 154
  • [38] Effects of different non-Newtonian models on unsteady blood flow hemodynamics in patient-specific arterial models with in-vivo validation
    Abbasian, Majid
    Shams, Mehrzad
    Valizadeh, Ziba
    Moshfegh, Abouzar
    Javadzadegan, Ashkan
    Cheng, Shaokoon
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 186