Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(R) System

被引:15
|
作者
Wazir, Umar [1 ,2 ]
Kasem, Iham [1 ]
Michell, Michael J. [1 ]
Suaris, Tamara [1 ]
Evans, David [1 ]
Malhotra, Anmol [1 ]
Mokbel, Kefah [1 ]
机构
[1] Princess Grace Hosp, London Breast Inst, London W1U 5NY, England
[2] Khyber Teaching Hosp, Dept Gen Surg, Peshawar 25000, Pakistan
关键词
breast cancer; localisation; occult; SAVI SCOUT® non-palpable breast lesions; reflector-guided localisation; RADIOACTIVE SEED LOCALIZATION; POOLED ANALYSIS; SURGERY; BIOPSY; WIRES;
D O I
10.3390/cancers13102409
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Marking impalpable areas of breast cancer prior to surgery is an important part of the modern treatment of breast cancer. Traditionally, the target lesion would be marked by a wire just before surgery under image guidance and would help the surgeon locate the tumour during surgery. However, this method has some drawbacks, such as patient discomfort, the risk of migration and dislodgement, and the need to couple surgical and radiological schedules. Therefore, there has been a growing interest in this system, thus supporting its potential. In this study, we have evaluated one such system, SAVI SCOUT(R), in 63 consecutive patients. Our experience with this system supported its potential role in modern breast surgery. Wire-guided localisation (WGL) has been the mainstay for localising non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localisation using the SAVI SCOUT(R) system at the London Breast Institute. A total of 72 reflectors were deployed in 67 consecutive patients undergoing breast conserving surgery for non-palpable breast lesions. The mean interval between deployment and surgery for the therapeutic cases was 18.8 days (range: 0-210). The median deployment duration was 5 min (range: 1-15 min). The mean distance from the lesion was 1.1 mm (median distance: 0; range: 0-20 mm). The rate of surgical localisation and retrieval of the reflector was 98.6% and 100%, respectively. The median operating time was 28 min (range: 15-55 min) for the therapeutic excision of malignancy and 17 min (range: 15-24) for diagnostic excision. The incidence of reflector migration was 0%. Radial margin positivity in malignant cases was 7%. The median weight for malignant lesions was 19.6 g (range: 3.5-70 g). Radiologists and surgeons rated the system higher than WGL (93.7% and 98.6%, respectively; 60/64 and 70/71). The patient mean satisfaction score was 9.7/10 (n = 47, median = 10; range: 7-10). One instance of signal failure was reported. In patients who had breast MRI after the deployment of the reflector, the MRI void signal was <5 mm (n = 6). There was no specific technique-related surgical complication. Our study demonstrates that wire-free localisation using SAVI SCOUT(R) is an effective and time-efficient alternative to WGL with excellent physician and patient acceptance.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Reflector-guided Localization of Non-palpable Breast Lesions: The First Reported European Evaluation of the SAVI SCOUT® System
    Tayeh, Salim
    Muktar, Samantha
    Heeney, Jennifer
    Michell, Michael J.
    Perry, Nicholas
    Suaris, Tamara
    Evans, David
    Malhotra, Anmol
    Mokbel, Kefah
    [J]. ANTICANCER RESEARCH, 2020, 40 (07) : 3915 - 3924
  • [2] SAVI Scout® System for Excision of Non-Palpable Breast Lesions
    Farha, Maen J.
    Simons, James
    Kfouri, Jad
    Townsend-Day, Michelle
    [J]. AMERICAN SURGEON, 2023, 89 (06) : 2434 - 2438
  • [3] Savi Scout® Radar Localisation of Non-palpable Breast Lesions: Systematic Review and Pooled Analysis of 842 Cases
    Kasem, Iham
    Mokbel, Kefah
    [J]. ANTICANCER RESEARCH, 2020, 40 (07) : 3633 - 3643
  • [4] Preoperative ultrasound guided needle localisation for non-palpable breast lesions
    Kalyan Das
    Diptendra Kumar Sarkar
    Rejaul Karim
    Asim Kumar Manna
    [J]. Indian Journal of Surgery, 2010, 72 : 117 - 123
  • [5] Preoperative ultrasound guided needle localisation for non-palpable breast lesions
    Das, Kalyan
    Sarkar, Diptendra Kumar
    Karim, Rejaul
    Manna, Asim Kumar
    [J]. INDIAN JOURNAL OF SURGERY, 2010, 72 (02) : 117 - 123
  • [6] A prospective, single-arm, multi-site, clinical evaluation of the SAVI SCOUT surgical guidance system for the location of non-palpable breast lesions during excision
    Cox, C. E.
    Prati, R.
    Blumencranz, P.
    Allen, K.
    Banull, C.
    Cline, M.
    Howard, T.
    Portillo, M.
    Whitworth, P.
    Funk, K.
    Police, A.
    Lin, E.
    Combs, F.
    Anglin, B.
    King, J.
    Shivers, S. C.
    [J]. CANCER RESEARCH, 2016, 76
  • [7] Localisation of non-palpable breast lesions prior to surgical excision: An evaluation of ultrasound guided RFID tag localisation vs guidewire localisation
    Dodgeon, Louise
    [J]. BREAST CANCER RESEARCH, 2021, 23 (SUPPL 2)
  • [8] Dual technique for preoperative localisation of non-palpable breast lesions
    Adwani, A
    Lowe, S
    [J]. JOURNAL OF SURGICAL ONCOLOGY, 2003, 84 (02) : 105 - 106
  • [9] Multicentre evaluation of magnetic technology for localisation of non-palpable breast lesions and targeted axillary nodes
    McCamley, Chere
    Ruyssers, Natacha
    To, Henry
    Tsao, Simon
    Keane, Holly
    Poliness, Cathie
    Mehta, Kirti
    Rose, Allison
    Baker, Caroline
    Mann, Gregory B.
    [J]. ANZ JOURNAL OF SURGERY, 2021, 91 (11) : 2411 - 2417
  • [10] Ultrasonographically guided excisional biopsy of non-palpable breast lesions
    DiGiorgio, A
    Alessi, G
    Arnone, P
    Canavese, A