SAVI Scout® System for Excision of Non-Palpable Breast Lesions

被引:5
|
作者
Farha, Maen J. [1 ]
Simons, James [2 ]
Kfouri, Jad [3 ]
Townsend-Day, Michelle [1 ]
机构
[1] MedStar Union Mem & Good Samaritan Hosp, Dept Surg, 5601 Loch Raven Blvd,Smyth 403B, Baltimore, MD 21239 USA
[2] Wright Ctr Grad Med Educ, Scranton, PA USA
[3] Univ Maryland, College Pk, MD 20742 USA
关键词
breast cancer; breast excision; wire localization; SAVI scout; magseed; LOCALIZATION; SURGERY; WIRES;
D O I
10.1177/00031348221096576
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The standard localization of non-palpable breast masses is wire/needle localization (WL). Newer technologies have evolved, allowing more efficient scheduling and improving surgeon and patient experiences. These include Radioactive Seed, MagSeed (R), and SAVI Scout (R) (SS). We adopted SS at our program in July of 2017. We are reporting our experience comparing SAVI Scout (R) with needle localization. Study Design This is a retrospective study comparing SS and wire localization techniques for the excision of both benign and malignant lesions. Chart reviews of localized patients between 7/1/2017 and 6/30/2019, recording the age of the patient, date of procedure, localization method, pathology of lesion postexcision, number and status of margins, guidance method (mammogram vs. ultrasound), specimen size, and distance of reflector from biopsy clip, were completed to compare these localization methods with the aim of asserting their equality. Results There were 48 wire and 64 SS localized excisions. Successful lesion excision was achieved in 100% of cases for both techniques. There were 1 SS and 4 WL re-excisions for margin clearance not reaching statistical significance. 51 additional margins were obtained in the SS cases compared to 36 margins in the WL cases without a statistically significant difference. Conclusions 1- Both SS and WL achieved 100% excision of targeted lesions 2- SS localization was successfully implemented, offering more convenience for patients and providers 3- More re-excisions in the WL group as compared to the SS group did not reach statistical significance and requires further investigation 4- A prospective controlled trial comparing the different localization techniques can address questions related to effectiveness, cost, patient and provider experiences.
引用
收藏
页码:2434 / 2438
页数:5
相关论文
共 50 条
  • [1] Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(R) System
    Wazir, Umar
    Kasem, Iham
    Michell, Michael J.
    Suaris, Tamara
    Evans, David
    Malhotra, Anmol
    Mokbel, Kefah
    [J]. CANCERS, 2021, 13 (10)
  • [2] Reflector-guided Localization of Non-palpable Breast Lesions: The First Reported European Evaluation of the SAVI SCOUT® System
    Tayeh, Salim
    Muktar, Samantha
    Heeney, Jennifer
    Michell, Michael J.
    Perry, Nicholas
    Suaris, Tamara
    Evans, David
    Malhotra, Anmol
    Mokbel, Kefah
    [J]. ANTICANCER RESEARCH, 2020, 40 (07) : 3915 - 3924
  • [3] Savi Scout® Radar Localisation of Non-palpable Breast Lesions: Systematic Review and Pooled Analysis of 842 Cases
    Kasem, Iham
    Mokbel, Kefah
    [J]. ANTICANCER RESEARCH, 2020, 40 (07) : 3633 - 3643
  • [4] A prospective, single-arm, multi-site, clinical evaluation of the SAVI SCOUT surgical guidance system for the location of non-palpable breast lesions during excision
    Cox, C. E.
    Prati, R.
    Blumencranz, P.
    Allen, K.
    Banull, C.
    Cline, M.
    Howard, T.
    Portillo, M.
    Whitworth, P.
    Funk, K.
    Police, A.
    Lin, E.
    Combs, F.
    Anglin, B.
    King, J.
    Shivers, S. C.
    [J]. CANCER RESEARCH, 2016, 76
  • [5] Combined image guidance excision of non-palpable breast lesions
    Benson, SRC
    Harrison, NJ
    Lengyel, J
    Deacon, C
    Isgar, B
    [J]. BREAST, 2004, 13 (02): : 110 - 114
  • [6] Non-palpable breast lesions
    Sandrini, R
    Pollini, GP
    Pellini, F
    Rettore, L
    Ghandour, HM
    Parise, V
    Vecchioni, R
    [J]. EUROPEAN JOURNAL OF CANCER, 1998, 34 : S56 - S56
  • [7] A Comparison of SAVI SCOUT Radar to the Radioactive I125 Seed in the Localization of Non-palpable Breast Cancer
    Rico, L. M.
    Raque, K. M.
    Yu, E.
    Truax, M.
    Carter, B.
    Frazier, T.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2017, 24 : S52 - S52
  • [8] Localization techniques for guided surgical excision of non-palpable breast lesions
    Chan, Benjamin K. Y.
    Wiseberg-Firtell, Jill A.
    Jois, Ramesh H. S.
    Jensen, Katrin
    Audisio, Riccardo A.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (12):
  • [9] Initial experience with Advanced Breast Biopsy Instrumentation, a system for excision of non-palpable mammary lesions
    Oertli, D
    Zuber, M
    Müller, D
    Marti, WR
    Köchli, OR
    Torhorst, J
    Harder, F
    [J]. SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 128 (21) : 811 - 816
  • [10] Wire localisation biopsy of non-palpable breast lesions: reasons for unsuccessful excision
    Kouskos, E
    Gui, GPH
    Mantas, D
    Revenas, K
    Rallis, N
    Antonopoulou, Z
    Lampadariou, E
    Gogas, H
    Markopoulos, C
    [J]. EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2006, 27 (03) : 262 - 266