The effects of accelerometer placement on mechanomyographic amplitude and mean power frequency during cycle ergometry

被引:16
|
作者
Zuniga, Jorge M. [1 ]
Housh, Terry J. [1 ]
Camic, Clayton L. [1 ]
Hendrix, C. Russell [1 ]
Mielke, Michelle [2 ]
Schmidt, Richard J. [1 ]
Johnson, Glen O. [1 ]
机构
[1] Univ Nebraska, Human Performance Lab, Dept Nutr & Hlth Sci, Lincoln, NE 68583 USA
[2] Univ Pacific, Dept Sport Sci, Stockton, CA 95211 USA
关键词
Proximal; Distal; Pedaling exercise; Mechanomyography; Vastus lateralis; Relationships; MOTOR UNIT-ACTIVITY; FASCICLE LENGTH; HUMAN MUSCLES; CONTRACTIONS; SIGNALS; ELECTROMYOGRAPHY; VOLUNTARY; EXERCISE; DISTANCE;
D O I
10.1016/j.jelekin.2010.01.001
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purposes of this study were threefold: (1) to compare the power output related patterns of absolute and normalized MMG amplitude and MPF responses for proximal and distal accelerometer placements on the vastus lateralis (VL) muscle during incremental cycle ergometry; (2) to examine the influence of accelerometer placements on mean absolute MMG amplitude and MPF values; and (3) to determine the effects of normalization on mean MMG amplitude and MPF values from proximal and distal accelerometer placements. Fifteen adults (10 men and 5 women; mean +/- SD age = 23.9 +/- 3.1 years) performed incremental cycle ergometry tests to exhaustion. Two accelerometers were placed proximal and distal on the VL muscle. Paired t-tests indicated that absolute MMG amplitude values for the proximal accelerometer were greater (p < 0.05) than the distal accelerometer at all power outputs. The normalized MMG amplitude also had greater values for the proximal accelerometer at all power outputs, except 50 W. There were no differences, however, between proximal and distal accelerometers for absolute MMG MPF, except at 75 W, and normalization eliminated this difference. Twenty-seven percent of the subjects exhibited different power output related patterns of responses between accelerometer placements for MMG amplitude and 47% exhibited different patterns for MPF. These findings indicated that normalization did not eliminate the influence of accelerometer placement on MMG amplitude and highlighted the importance of standardizing accelerometer placements to compare MMG values during cycle ergometry. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:719 / 725
页数:7
相关论文
共 50 条
  • [31] Effects of the production of perceived exertion during cycle ergometry
    Akimov E.B.
    Alekseev V.M.
    Human Physiology, 2008, 34 (6) : 766 - 770
  • [32] Effects of Endurance Cycling on Mechanomyographic Median Power Frequency of the Vastus Lateralis
    Perez, Sergio
    Olmos, Alex A.
    Sontag, Stephanie A.
    Parra, Mandy E.
    Dimmick, Hannah L.
    Sterczala, Adam J.
    Miller, Jonathan D.
    Deckert, Jake A.
    Herda, Trent J.
    Trevino, Michael A.
    APPLIED SCIENCES-BASEL, 2022, 12 (10):
  • [33] The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii
    Beck, TW
    Housh, TJ
    Johnson, GO
    Weir, JP
    Cramer, JT
    Coburn, JW
    Malek, MH
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (05) : 482 - 495
  • [34] Power Output and Efficiency During Supine, Recumbent, and Upright Cycle Ergometry
    Wehrle, Anja
    Waibel, Sarah
    Gollhofer, Albert
    Roecker, Kai
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2021, 3
  • [35] The effects of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis muscle
    Beck, Travis W.
    Housh, Terry J.
    Cramer, Joel T.
    Weir, Joseph P.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (02) : 317 - 328
  • [36] THE EFFECT OF PEDAL CADENCE AND POWER OUTPUT ON RPE DURING CYCLE ERGOMETRY
    Boutcher, S. H.
    Hamer, M.
    Nurhayati, Y.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S279 - S279
  • [37] BLOOD LACTATE IN TRAINED CYCLISTS DURING CYCLE ERGOMETRY AT CRITICAL POWER
    JENKINS, DG
    QUIGLEY, BM
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1990, 61 (3-4): : 278 - 283
  • [38] EFFECTS OF DIVERTING ACTIVITIES ON ELECTROMYOGRAPHIC AMPLITUDE AND MEAN FREQUENCY
    Stock, Matt S.
    Beck, Travis W.
    DeFreitas, Jason M.
    KINESIOLOGY, 2013, 45 (02) : 222 - 232
  • [39] The influence of electrode placement over the innervation zone on electromyographic amplitude and mean power frequency versus isokinetic torque relationships
    Beck, Travis W.
    Housh, Terry J.
    Mielke, Michelle
    Cramer, Joel T.
    Weir, Joseph P.
    Malek, Moh H.
    Johnson, Glen O.
    JOURNAL OF NEUROSCIENCE METHODS, 2007, 162 (1-2) : 72 - 83
  • [40] Median power frequency of the surface electromyogram and blood lactate concentration in incremental cycle ergometry
    Jansen, R
    Ament, W
    Verkerke, GJ
    Hof, AL
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1997, 75 (02) : 102 - 108