Non-Rigid Respiratory Motion Correction for 4D Gated PET Sinogram Data

被引:0
|
作者
Feng, Tao [1 ]
Tsui, Benjamin M. W. [2 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, 3400 N Charles St, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ Hosp, Dept Radiol, Baltimore, MD 21287 USA
关键词
SIMULATION; RECONSTRUCTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Respiratory motion is one image degradation factor that affects the resolution and may cause artifacts in PET imaging. Respiratory gating technique is able to reduce the blurring effects but results in higher noise level. Conventional motion correction methods that model motion effects during or after image reconstruction not only increases reconstruction time, but also requires a gated or blurred attenuation map to reduce motion artifacts. This paper addresses the respiratory motion correction on sinogram data before reconstruction using a non-rigid motion model. It has the potential to reduce reconstruction time, and does not require gated attenuation maps.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Non-rigid dual respiratory and cardiac motion correction methods after, during, and before image reconstruction for 4D cardiac PET
    Feng, Tao
    Wang, Jizhe
    Fung, George
    Tsui, Benjamin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : 151 - 168
  • [2] TOF Data Non-Rigid Motion Correction
    Panin, V. Y.
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] Respiratory motion correction in PET with super-resolution techniques and non-rigid registration
    Rubio-Guivernau, Jose L.
    Ledesma-Carbayo, Maria J.
    Lamare, Frederic
    Ortuno, Juan E.
    Guerra, Pedro
    Visvikis, Dimitris
    Santos, Andres
    Kontaxakis, George
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3560 - +
  • [4] Estimation and Correction of Rigid and Non-Rigid Respiratory Motion of the Heart for SPECT
    Dey, Joyoni
    Feng, Bing
    Johnson, Karen L.
    Pretorius, P. Hendrik
    King, Michael A.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2111 - 2115
  • [5] Motion correction for gated PET using sinogram registration
    Detorie, Nicole C.
    Dahlbom, Magnus
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3577 - 3582
  • [6] Respiratory motion correction in PET with gated PET/CT data
    Iglesias, J. E.
    Kimiaei, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S315 - S315
  • [7] VALIDATION OF A NON-RIGID REGISTRATION METHOD FOR MOTION COMPENSATION IN 4D ULTRASOUND OF THE LIVER
    Vijayan, Sinara
    Klein, Stefan
    Hofstad, Erlend Fagertun
    Lindseth, Frank
    Ystgaard, Brynjulf
    Lango, Thomas
    [J]. 2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 792 - 795
  • [8] Non-rigid Full Torso Respiratory Motion Correction of SPECT Studies
    Dey, Joyoni
    King, Michael A.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2356 - 2358
  • [9] List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations
    Lamare, F.
    Carbayo, M. J. Ledesma
    Cresson, T.
    Kontaxakis, G.
    Santos, A.
    Le Rest, C. Cheze
    Reader, A. J.
    Visvikis, D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (17): : 5187 - 5204
  • [10] 4D Match Trees for Non-rigid Surface Alignment
    Mustafa, Armin
    Kim, Hansung
    Hilton, Adrian
    [J]. COMPUTER VISION - ECCV 2016, PT I, 2016, 9905 : 213 - 229