TOF Data Non-Rigid Motion Correction

被引:0
|
作者
Panin, V. Y. [1 ]
机构
[1] Siemens Healthcare, Mol Imaging, Knoxville, TN 37932 USA
关键词
RESPIRATORY MOTION; PET DATA; RECONSTRUCTION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET acquisition requires prolonged scan times, and during the scan a large magnitude of patient motion can occur. Breathing may result in a significant displacement of organs and consequent blurring of clinically relevant features. Various non-rigid motion corrections that act in the image space were proposed to address this problem. TOF data can be considered to be histo-images. Therefore, non-rigid motion correction can be performed in this quasi image space. The TOF locality property can be used to locally perform motion correction; that is, the approximation of motion as locally rigid on a scale of TOF resolution. In this work we investigate motion correction in the TOF data space, assuming a known motion field. Data correction factors, such as normalization and attenuation, will be combined for motion compensation depending on the combination of data. The benefit of the presented motion correction is that only one data set needs to be used for the final reconstruction. An XCAT phantom is used in computer simulations. Initial results showed that the presented methodology accommodates for changes in non-rigid body movements for a typical pattern of patient motion.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Estimation and Correction of Rigid and Non-Rigid Respiratory Motion of the Heart for SPECT
    Dey, Joyoni
    Feng, Bing
    Johnson, Karen L.
    Pretorius, P. Hendrik
    King, Michael A.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2111 - 2115
  • [2] RETROSPECTIVE CORRECTION OF RIGID AND NON-RIGID MR MOTION ARTIFACTS USING GANS
    Armanious, Karim
    Gatidis, Sergios
    Nikolaou, Konstantin
    Yang, Bin
    Kuestner, Thomas
    [J]. 2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 1550 - 1554
  • [3] Improved Motion Correction in SPECT Imaging Using a Non-rigid Motion Model
    Gu, Songxiang
    McNamara, Joseph E.
    Joyeeta, Mitra
    Johnson, Karen
    Gifford, Howard
    Pretorius, Hendrik
    Sklyar, Andrey V.
    Gennert, Michael A.
    King, Michael A.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3242 - 3246
  • [4] Non-Rigid Respiratory Motion Correction for 4D Gated PET Sinogram Data
    Feng, Tao
    Tsui, Benjamin M. W.
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [5] Rigid and non-rigid structure from motion
    Ganis, G.
    Casco, C.
    Roncato, S.
    [J]. PERCEPTION, 1990, 19 (04) : 389 - 389
  • [6] Non-rigid Full Torso Respiratory Motion Correction of SPECT Studies
    Dey, Joyoni
    King, Michael A.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2356 - 2358
  • [7] Non-rigid Motion Correction for Ultrasound Localization Microscopy of the Liver in vivo
    Hao, Yayu
    Wang, Qin
    Yang, Yi
    Liu, Zhi
    He, Qiong
    Wei, Lai
    Luo, Jianwen
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2263 - 2266
  • [8] Deep Non-Rigid Structure From Motion With Missing Data
    Kong, Chen
    Lucey, Simon
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2021, 43 (12) : 4365 - 4377
  • [9] A simultaneous estimation of rigid and non-rigid face motion
    Lee, J
    Yang, YS
    [J]. 15TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 1, PROCEEDINGS: COMPUTER VISION AND IMAGE ANALYSIS, 2000, : 1068 - 1071
  • [10] The effect of rigid and non-rigid motion on object recognition
    Newell, F. N.
    Setti, A.
    [J]. PERCEPTION, 2006, 35 : 184 - 185