Chest compression with kneeling posture in hospital cardiopulmonary resuscitation: A randomised crossover simulation study

被引:10
|
作者
Oh, Jaehoon [1 ]
Chee, Youngjoon [2 ]
Lim, Taeho [1 ]
Cho, Youngsuk [3 ]
Kim, In Young [4 ]
机构
[1] Hanyang Univ, Coll Med, Dept Emergency Med, Seoul 133791, South Korea
[2] Univ Ulsan, Sch Elect Engn, Ulsan 680749, South Korea
[3] Hallym Univ, Coll Med, Dept Emergency Med, Seoul, South Korea
[4] Hanyang Univ, Coll Med, Dept Biomed Engn, Seoul 133791, South Korea
关键词
cardiac arrest; cardiopulmonary resuscitation; compression; posture; simulation; BASIC LIFE-SUPPORT; OVER-THE-HEAD; BED HEIGHT; RESCUER FATIGUE; CARDIAC-ARREST; STEP STOOL; POSITION; QUALITY; PERFORMANCE; GUIDELINES;
D O I
10.1111/1742-6723.12307
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
PurposeWe suggest an alternative chest compression (CC) in kneeling posture using a kneeling stool' on which the performer kneels beside the patient on a bed in-hospital. In kneeling posture, we can maintain high quality cardiopulmonary resuscitation (CPR) without the bed height adjustment, which is necessary and inconvenient in standing posture. MethodsThis study is a randomised crossover trial with 38 participants working in one ED. The first group knelt on the kneeling stool beside a manikin placed on a bed, whereas the second group stood on a step stool with the manikin at knee level using bed height adjustment. All the participants performed continuous chest compression for 5min without audio-visual feedback. After that, the posture was changed in each group. The parameters of CC quality (CC depth, rate, accuracy, and incomplete chest recoil), visual analogue scale (VAS) for fatigue and pain, and preference of participants were compared between the two groups. ResultsThe data of 33 participants in both postures were analysed following exclusion of five participants. In the comparisons overall and per minute between the two postures, the parameters and VAS do not differ significantly (all P > 0.05) except for the median 1st CC rate that was faster in kneeling posture than in standing posture, P = 0.01). Twenty-three performers preferred the kneeling posture. ConclusionsA kneeling posture with a kneeling stool were preferred by participants, which have shown similar results in CC parameters and VAS with a standing posture on a stepstool with bed height adjustment during in-hospital CPR.
引用
收藏
页码:585 / 590
页数:6
相关论文
共 50 条
  • [41] Cardiopulmonary resuscitation feedback improves the quality of chest compression provided by hospital health care professionals
    Pozner, Charles N.
    Almozlino, Adam
    Elmer, Jonathan
    Poole, Stephen
    McNamara, De'Ann
    Barash, David
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (06): : 618 - 625
  • [42] Is chest compression only as effective as standard treatment in out-of-hospital bystander cardiopulmonary resuscitation?
    Bohm, K.
    Rosenqvist, M.
    Herlitz, J.
    Svensson, L.
    EUROPEAN HEART JOURNAL, 2007, 28 : 528 - 528
  • [43] Chest compression-only cardiopulmonary resuscitation and duration of out-of-hospital cardiac arrest
    Goto, Y.
    Funada, A.
    Goto, Y.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1382 - 1383
  • [44] THE IMPORTANCE OF VICTIM CHEST EXPOSURE DURING CARDIOPULMONARY RESUSCITATION: A SIMULATION STUDY
    Jo, Choong Hyun
    Cho, Gyu Chong
    Ahn, Jung Hwan
    Ryu, Ji Yeong
    JOURNAL OF EMERGENCY MEDICINE, 2015, 48 (02): : 165 - +
  • [45] Assessment of optimal chest compression depth during neonatal cardiopulmonary resuscitation: a randomised controlled animal trial
    Bruckner, Marlies
    Kim, Seung Yeon
    Shim, Gyu Hong
    Neset, Mattias
    Garcia-Hidalgo, Catalina
    Lee, Tze-Fun
    O'Reilly, Megan
    Cheung, Po-Yin
    Schmolzer, Georg M.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2022, 107 (03): : 262 - 268
  • [46] The effect of inclined step stool on the quality of chest compression during in-hospital cardiopulmonary resuscitation
    Yun, Seong-Woo
    Lee, Byung Kook
    Jeung, Kyung Woon
    Park, Sang Wook
    Choi, Sung Soo
    Lee, Chang-Hee
    Ryu, So-Yeon
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (08): : 851 - 855
  • [47] Chest compression during sustained inflation versus 3: 1 chest compression: ventilation ratio during neonatal cardiopulmonary resuscitation: a randomised feasibility trial
    Schmolzer, Georg M.
    Reilly, Megan O.
    Fray, Caroline
    van Os, Sylvia
    Cheung, Po-Yin
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2018, 103 (05): : F455 - F460
  • [48] Realizing Optimal Chest Compression Fraction During Cardiopulmonary Resuscitation
    Talkington, Josh
    Dantu, Ram
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 348 - 349
  • [49] Effects of Chest Compression on Ventilation Quality during Cardiopulmonary Resuscitation
    Ding, Bozhi
    Pan, Chang
    Pang, Jiaojiao
    Wang, Jiali
    Li, Ke
    Xu, Feng
    Chen, Yuguo
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [50] Backboard use during cardiopulmonary resuscitation and chest compression quality
    Paganini, Matteo
    Mormando, Giulia
    Carfagna, Fabio
    Ingrassia, Pier Luigi
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2022, 29 (05) : 387 - 387