Gliclazide voltammetric sensor based on electropolymerized molecularly imprinted polypyrrole film onto glassy carbon electrode

被引:31
|
作者
Hrichi, Hajer [1 ]
Louhaichi, Mohamed Radhouan [2 ]
Monser, Lotfi [1 ]
Adhoum, Nafaa [1 ,3 ]
机构
[1] Carthage Univ, Natl Inst Appl Sci & Technol, Ctr Urbain Nord, Tunis 1080, Tunisia
[2] Natl Lab Pharmaceut Control, Tunis, Tunisia
[3] Kairouan Univ, Preparatory Sch Engn Studies, Kairouan, Tunisia
来源
关键词
Molecularly imprinted polymer; Polypyrrole; Glassy carbon electrode; Electropolymerization; Gliclazide; PERFORMANCE LIQUID-CHROMATOGRAPHY; ELECTROCHEMICAL SENSORS; DOSAGE FORMS; GLIPIZIDE; OXIDATION; METFORMIN; POLYMERS; STRATEGY; COLUMN; ACID;
D O I
10.1016/j.snb.2014.07.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gliclazide sensing was investigated based on differential pulse voltammetry measurements of an electropolymerized molecularly imprinted polymer (E-MIP) film. The E-MIP polymer was prepared via anodic electropolymerization of pyrrole in the presence of GLZ onto glassy carbon electrodes using cyclic voltammetry (CV). GLZ molecules are successfully trapped into the polypyrrole matrix creating, after their subsequent removal, shape-complementary artificial recognition sites. The effect of several significant operational parameters (monomer and template concentrations, number of CV scans, pH and incubation time) on film analytical performances were investigated and optimized. Under optimized conditions, the sensor response exhibited high sensitivity toward the target template and was linearly proportional to GLZ concentration (R-2 = 0.998) over the range 5 x 10(-11)4 x 10(-10) M, with a detection limit (3 sigma/m) of 1.2 x 10(-11) M. The precision of the method (R.S.D., n = 6) for within and between-days is better than 1.4% and 2.48%, respectively at 10(-10) M. Moreover, the selectivity of E-MIP sensor, against potentially competing molecules (Imp. B, Imp. E, glipizide, glibenclamide, glimepiride), was demonstrated. The developed E-MIP sensor was successfully applied to the determination of GLZ in three pharmaceutical products and gave results in close agreement with the reference HPLC method with mean recoveries between 95.4 and 98.8%, showing promising potential in practical applications. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 50 条
  • [31] A hemin-based molecularly imprinted polymer (MIP) grafted onto a glassy carbon electrode as a selective sensor for 4-aminophenol amperometric
    Martins Neto, Jose de Ribamar
    Rodrigues Santos, Wilney de Jesus
    Rodrigues Lima, Phabyanno
    Carvalho Neiva Tanaka, Sonia Maria
    Tanaka, Auro Atsushi
    Kubota, Lauro Tatsuo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (02): : 220 - 225
  • [32] A core-shell molecularly imprinted polymer grafted onto a magnetic glassy carbon electrode as a selective sensor for the determination of metronidazole
    Chen, Dan
    Deng, Jian
    Liang, Jun
    Xie, Jie
    Hu, Canhui
    Huang, Kaihui
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 594 - 600
  • [33] Selective Electrochemical Determination of Etoposide Using a Molecularly Imprinted Overoxidized Polypyrrole Coated Glassy Carbon Electrode
    Hrichi, Hajer
    Monser, Lotfi
    Adhoum, Nafaa
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2019, 2019
  • [34] Voltammetric response of 2,4-D-molecularly imprinted film modified glassy carbon electrodes
    Wang, Zhihua
    Kang, Jingwan
    Liu, Xiaoyu
    Ma, Yongjun
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2006, 45 (08): : 1848 - 1851
  • [35] Molecularly Imprinted Polymer Based Sensor for Measuring of Levodopa: Evaluation as a Modifier for Glassy Carbon Electrode in Electrochemically Detection
    Siavashi, Reza
    Beitollahi, Hadi
    [J]. RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2023, 59 (01) : 70 - 78
  • [36] Electrochemical Sensor for Detection of Trichlorfon Based on Molecularly Imprinted Sol–Gel Films Modified Glassy Carbon Electrode
    Weiqiang Gao
    Fuwei Wan
    Wei Ni
    Shaowei Wang
    Meng Zhang
    Jinghua Yu
    [J]. Journal of Inorganic and Organometallic Polymers and Materials, 2012, 22 : 37 - 41
  • [38] A kanamycin sensor based on an electrosynthesized molecularly imprinted poly-o-phenylenediamine film on a single-walled carbon nanohorn modified glassy carbon electrode
    Han, Shuang
    Li, Bingqian
    Song, Ze
    Pan, Sihao
    Zhang, Zhichao
    Yao, Hui
    Zhu, Shuyun
    Xu, Guobao
    [J]. ANALYST, 2017, 142 (01) : 218 - 223
  • [39] Voltammetric dopamine sensor based on three-dimensional electrosynthesized molecularly imprinted polymers and polypyrrole nanowires
    Teng, Ying
    Liu, Fen
    Kan, Xianwen
    [J]. MICROCHIMICA ACTA, 2017, 184 (08) : 2515 - 2522
  • [40] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Hongxiu Dai
    Nan Wang
    Donglei Wang
    Xiaomei Zhang
    Houyi Ma
    Meng Lin
    [J]. Microchimica Acta, 2016, 183 : 3053 - 3059