The modified anterior ellipsoidal cap titanium cable tension band for comminuted patellar fractures

被引:3
|
作者
Wang, Fasheng [1 ]
Luo, Tianyi David [2 ]
Chen, Chunyong [1 ]
Xie, Yun [1 ]
Lin, Zhangxiong [1 ]
Zeng, Da [3 ]
Lin, Jianhua [1 ]
Ye, Junjian [1 ]
机构
[1] Fujian Med Univ, Affiliated Hosp 1, Trauma Ctr Fujian, Dept Orthopaed Trauma, 20 Chazhong Rd, Fuzhou 350005, Fujian, Peoples R China
[2] Wake Forest Baptist Med Ctr, Dept Orthopaed Surg, Winston Salem, NC USA
[3] Xiamen Med Device Res & Testing Ctr, Biomech Lab, Xiamen, Fujian, Peoples R China
关键词
cerclage; comminuted patellar fracture; modified anterior tension band; patellar fracture; titanium cable; INTERNAL-FIXATION; POLE FRACTURES; CERCLAGE; MANAGEMENT;
D O I
10.1177/2309499019874018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to assess the outcomes in a series of patients, who underwent cerclage and figure-of-eight tension band wiring using a single titanium cable for comminuted patellar fractures. Methods: We describe a modified tension band technique using a single titanium cable to create an ellipsoidal cap structure that combines the circumferential and figure-of-eight wrapping in the fixation of closed Association for the Study of Internal Fixation/Orthopaedic Trauma Association 34C2 and 34C3 patellar fractures. We retrospectively reviewed 25 patients (16 males and 9 females, mean age 54 years) who underwent the described fixation technique between 2015 and 2017. Postoperative function was evaluated using the Bostman score. Results: At the mean follow-up of 25 months (range 17-39 months), the mean Bostman score was 27.3 +/- 2.6 points (range 23-30). Eighteen patients (72%) had excellent results (score >= 28); seven patients (28%) had good results (score 20-27); and no patients had an unsatisfactory result (score < 20). All surgical incisions healed without major wound complications. Two patients reported minor complications (soft tissue irritation, cellulitis). No patients demonstrated loss of reduction or implant failure during the follow-up period. Conclusion: The modified anterior ellipsoidal cap tension band using a single titanium cable created an effective tension band structure in the treatment of comminuted patella fractures. It is a simple operative technique that produced a stable fixation construct, which allowed early functional rehabilitation and weight-bearing with a high rate of excellent outcomes at 2 years after surgery.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] What leads to unfavourable Cybex test results for quadriceps power after modified tension band osteosynthesis of patellar fractures?
    Bayar, A
    Sener, E
    Keser, S
    Meray, J
    Simsek, A
    Senköylü, A
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (06): : 520 - 524
  • [42] REPAIR OF COMMINUTED FRACTURES OF THE PROXIMAL ULNA AND OLECRANON IN YOUNG HORSES USING TENSION BAND PLATING
    COLAHAN, PT
    MEAGHER, DM
    AUSTRALIAN VETERINARY PRACTITIONER, 1980, 10 (02): : 111 - 118
  • [43] Two-Tension-Band Technique in Revision Surgery for Fixation Failure of Patellar Fractures
    Xue, Zichao
    Qin, Hui
    Ding, Haoliang
    Xu, Haitao
    An, Zhiquan
    MEDICAL SCIENCE MONITOR, 2016, 22 : 2736 - 2741
  • [44] MODIFIED TENSION BAND WIRING OF MEDIAL MALLEOLAR ANKLE FRACTURES
    GEORGIADIS, GM
    WHITE, DB
    FOOT & ANKLE INTERNATIONAL, 1995, 16 (02) : 64 - 68
  • [45] Modified Tension Band Fixation for Unstable Distal Clavicle Fractures
    Chun, Jae-Myeung
    Kim, Soung-Yon
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (05): : E88 - E92
  • [46] Surgical treatment of comminuted intra-articular fractures of the distal humerus with double tension band osteosynthesis
    Zhao, J
    Wang, XW
    Zhang, QL
    ORTHOPEDICS, 2000, 23 (05) : 449 - 452
  • [47] Comparison of a Novel Tension Band and Patellotibial Tubercle Cerclage in the Treatment of Comminuted Fractures of Inferior Pole of the Patella
    Zhang, Zhi-shan
    Li, Peng-fei
    Zhou, Fang
    Tian, Yun
    Ji, Hong-quan
    Guo, Yan
    Lv, Yang
    Yang, Zhong-wei
    Hou, Guo-jin
    ORTHOPAEDIC SURGERY, 2020, 12 (01) : 224 - 232
  • [48] Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures
    Lin, Tao
    Liu, Junbin
    Xiao, Baojun
    Fu, Dehao
    Yang, Shuhua
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [49] Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures
    Tao Lin
    Junbin Liu
    Baojun Xiao
    Dehao Fu
    Shuhua Yang
    BMC Musculoskeletal Disorders, 16
  • [50] FiberWire® is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures
    Wright, P. B.
    Kosmopoulos, V.
    Cote, R. E.
    Tayag, T. J.
    Nana, A. D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (11): : 1200 - 1203