Experimental Assessment Of The Tilt Angle Influence On The Solar Thermal Collectors Performance

被引:0
|
作者
Cotorcea, Alexandra [1 ]
Pocora, Andrei [1 ]
Nicolae, Florin [1 ]
Visa, Ion [2 ]
Moldovan, Macedon [2 ]
机构
[1] Mircea Cel Batran Naval Acad, Fac Nav & Naval Management, Constanta, Romania
[2] Transilvania Univ Brasov, Renewable Energy Syst & Recycling Res Ctr, Brasov, Romania
关键词
solar thermal; tilt angle; collector performance; ENERGY;
D O I
10.1109/eeae49144.2020.9278970
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Solar thermal collectors are usually installed at a fixed tilt angle. In the design stage of the solar thermal systems, the optimal value of the tilt angle is numerically evaluated according to the latitude and the climate of the location, aiming to maximize the yearly received solar energy and thus the yearly thermal energy output. To experimentally evaluate the influence of the tilt angle on the thermal energy output of the solar thermal collectors, a complex research infrastructure was developed in the Renewable Energy Systems and Recycling (RESREC) Research Centre of the Transilvania University of Brasov, Romania, consisting of nine solar thermal systems with flat plate and evacuated tubes solar thermal collectors. The solar thermal collectors were installed at tilt angles ranging between 0 degrees and 90 degrees on the rooftops of nine buildings in the R&D Institute to evaluate in the same time their performances under the continental temperate climate conditions of Brasov city (45.65 degrees N, 25.59 degrees E). The experimental results obtained in three types of days (sunny, intermediate and cloudy) are comparatively presented in the paper. The influence of the tilt angle on the thermal energy output of each type of solar thermal collector is discussed during the three types of days. Thus, the maximum thermal energy output was obtained in the case of the solar collectors tilted at 40 degrees. Differences up to 10 degrees... 15 degrees of this angle did not significantly affect the output, only the extreme values of the tilt angle (0 degrees and 90 degrees) showed negative influence.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] EXPERIMENTAL ANALYSIS OF THERMAL PERFORMANCE OF SOLAR AIR COLLECTORS WITH ALUMINUM FOAM OBSTACLES
    Bayrak, Fatih
    Oztop, Hakan F.
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2015, 35 (01) : 11 - 20
  • [32] Performance testing of thermal and photovoltaic thermal solar collectors
    Allan, James
    Dehouche, Zahir
    Stankovic, Sinisa
    Mauricette, Lascelle
    ENERGY SCIENCE & ENGINEERING, 2015, 3 (04): : 310 - 326
  • [33] THERMAL PERFORMANCE OF CARBON NANOTUBE NANOFLUIDS IN SOLAR MICROCHANNEL COLLECTORS: AN EXPERIMENTAL STUDY
    Ahlatli, Selim
    Mare, Thierry
    Estelle, Patrice
    Doner, Nimet
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2016, 7 (02) : 219 - 226
  • [34] A Comparative Thermal Performance Assessment of Various Solar Collectors for Domestic Water Heating
    Kalair, Ali Raza
    Seyedmahmoudian, Mehdi
    Saleem, Muhammad Shoaib
    Abas, Naeem
    Rauf, Shoaib
    Stojcevski, Alex
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2022, 2022
  • [35] Assessment of the use of solar thermal collectors for desalination
    Horta, P.
    Zaragoza, G.
    Alarcon-Padilla, D. C.
    DESALINATION AND WATER TREATMENT, 2015, 55 (10) : 2856 - 2867
  • [37] Thermal performance of parabolic trough solar collectors
    Conrado, L. Salgado
    Rodriguez-Pulido, A.
    Calderon, G.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 : 1345 - 1359
  • [39] TESTING THE THERMAL PERFORMANCE OF UNCOVERED SOLAR COLLECTORS
    SOLTAU, H
    SOLAR ENERGY, 1992, 49 (04) : 263 - 272
  • [40] Optimum tilt angle of solar collectors for building applications in mid-latitude zone
    Soulayman, S.
    Hammoud, M.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 124 : 20 - 28