Improvement of NDIR Carbon Dioxide Sensor Accuracy

被引:0
|
作者
Marinov, Marin [1 ]
Nikolov, Georgi [1 ]
Gieva, Elitsa [2 ]
Ganev, Borislav [1 ]
机构
[1] Tech Univ Sofia, Dept Elect, Sofia, Bulgaria
[2] Tech Univ Sofia, Dept Microelect, Sofia, Bulgaria
来源
2015 38TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY (ISSE 2015) | 2015年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Carbon dioxide sensors are extensively used in modern ventilation systems. Their accuracy and long term stability can crucially affect the overall effectiveness of the systems. This study is focused on the investigation of the possibilities for improving the accuracy of the most often used CO2 sensors in ventilation systems, namely the non-dispersive infrared (NDIR) sensors. An important problem with this technology is that the required light source changes its intensity over time but there are also a number of other factors which can significantly reduce the accuracy. The estimation of their impact and examination of approaches for accuracy improvement of NDIR CO2 sensors is the main purpose of this study. Finally, an experimental setup was implemented in a LabVIEW programming environment and real life measurements were carried out. The proposed methods are compared and evaluated in a quantitative way on the basis of the experimental data. The results prove that the proposed approach can improve the accuracy and reliability of CO2 concentration measurement.
引用
收藏
页码:466 / 471
页数:6
相关论文
共 50 条
  • [21] A miniature chemiresistor sensor for carbon dioxide
    Srinives, Sira
    Sarkar, Tapan
    Hernandez, Raul
    Mulchandani, Ashok
    ANALYTICA CHIMICA ACTA, 2015, 874 : 54 - 58
  • [22] A combined ear sensor for pulse oximetry and carbon dioxide tension monitoring: Accuracy in critically Ill children
    Tschupp, A
    Fanconi, S
    ANESTHESIA AND ANALGESIA, 2003, 96 (01): : 82 - 84
  • [23] ACCURACY OF A COMMERCIAL MICRO CARBON DIOXIDE ELECTRODE
    BATTISTINI, A
    WARING, WW
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1969, 100 (02): : 237 - +
  • [24] Development of a low-cost NDIR system for ppm detection of carbon dioxide in exhaled breath analysis
    Vincent, T. A.
    Urasinska-Wojcik, B.
    Gardner, J. W.
    EUROSENSORS 2015, 2015, 120 : 388 - 391
  • [25] Use of a dynamic enclosure approach to test the accuracy of the NDIR sensor:: Evaluation based on the CO2 equilibration pattern
    Pandey, Sudhir Kumar
    Kim, Ki-Hyun
    Lee, Sun-Ho
    SENSORS, 2007, 7 (12) : 3459 - 3471
  • [26] USE OF CARBON DIOXIDE FOR WATER INJECTIVITY IMPROVEMENT
    RAMSAY, HJ
    SMALL, FR
    JOURNAL OF PETROLEUM TECHNOLOGY, 1964, 16 (01): : 25 - &
  • [27] Field of View and Accuracy Improvement of a Coarse Sun Sensor
    Gulmammadov, Farid
    Akyazi, Bektas
    Kamisci, Emre
    2023 10TH INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN AIR AND SPACE TECHNOLOGIES, RAST, 2023,
  • [28] Target localization accuracy improvement via sensor mobility
    Ababneh, Ahmad A.
    INTERNATIONAL JOURNAL OF PARALLEL EMERGENT AND DISTRIBUTED SYSTEMS, 2019, 34 (05) : 594 - 614
  • [29] A low cost MEMS based NDIR system for the monitoring of carbon dioxide in breath analysis at ppm levels.
    Vincent, T. A.
    Gardner, J. W.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 954 - 964
  • [30] Telemetric carbon dioxide sensor for medical applications
    Yao, S
    Zhang, YS
    Madou, M
    TECHNICAL DIGEST OF THE SEVENTH INTERNATIONAL MEETING ON CHEMICAL SENSORS, 1998, : 494 - 496