Improvement of NDIR Carbon Dioxide Sensor Accuracy

被引:0
|
作者
Marinov, Marin [1 ]
Nikolov, Georgi [1 ]
Gieva, Elitsa [2 ]
Ganev, Borislav [1 ]
机构
[1] Tech Univ Sofia, Dept Elect, Sofia, Bulgaria
[2] Tech Univ Sofia, Dept Microelect, Sofia, Bulgaria
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Carbon dioxide sensors are extensively used in modern ventilation systems. Their accuracy and long term stability can crucially affect the overall effectiveness of the systems. This study is focused on the investigation of the possibilities for improving the accuracy of the most often used CO2 sensors in ventilation systems, namely the non-dispersive infrared (NDIR) sensors. An important problem with this technology is that the required light source changes its intensity over time but there are also a number of other factors which can significantly reduce the accuracy. The estimation of their impact and examination of approaches for accuracy improvement of NDIR CO2 sensors is the main purpose of this study. Finally, an experimental setup was implemented in a LabVIEW programming environment and real life measurements were carried out. The proposed methods are compared and evaluated in a quantitative way on the basis of the experimental data. The results prove that the proposed approach can improve the accuracy and reliability of CO2 concentration measurement.
引用
收藏
页码:466 / 471
页数:6
相关论文
共 50 条
  • [1] Carbon Dioxide Sensor Module Based on NDIR Technology
    Zhou, Libing
    He, Yaoyi
    Zhang, Qing
    Zhang, Lei
    MICROMACHINES, 2021, 12 (07)
  • [2] NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings
    Mendes, Luciano B.
    Ogink, Nico W. M.
    Edouard, Nadege
    van Dooren, Hendrik Jan C.
    Tinoco, Ilda de Fatima F.
    Mosquera, Julio
    SENSORS, 2015, 15 (05): : 11239 - 11257
  • [3] Quantifying direct carbon dioxide emissions from wastewater treatment units by nondispersive infrared sensor (NDIR) - A pilot study
    Kosse, Pascal
    Kleeberg, Tasja
    Luebken, Manfred
    Matschullat, Joerg
    Wichern, Marc
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 633 : 140 - 144
  • [4] Carbon Dioxide Sensor for Mobile Devices A novel approach for low-power consuming, highly sensitive NDIR sensors
    Scholz, Louisa
    Perez, Alvaro Ortiz
    Bierer, Benedikt
    Eaksen, Ponkanok
    Woellenstein, Juergen
    Palzer, Stefan
    2016 IEEE SENSORS, 2016,
  • [5] Measurement of Methane and Carbon Dioxide Emissions from Ruminants Based on the NDIR Technique
    Ding Xue-zhi
    Long Rui-jun
    Mi Jian-dui
    Guo Xu-sheng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (06) : 1503 - 1506
  • [6] Non-dispersive infra-red (NDIR) measurement of carbon dioxide at 4.2 μm in a compact and optically efficient sensor
    Hodgkinson, Jane
    Smith, Richard
    Ho, Wah On
    Saffell, John R.
    Tatam, Ralph P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 : 580 - 588
  • [7] IMPROVING THE ACCURACY OF THE NDIR-BASED CO2 SENSOR FOR BREATH ANALYSIS
    Prokopiuk, Artur
    Bielecki, Zbigniew
    Wojtas, Jacek
    METROLOGY AND MEASUREMENT SYSTEMS, 2021, 28 (04) : 803 - 812
  • [8] Dynamic characteristics calibration and dynamic performance improvement of infrared carbon dioxide sensor
    Wu, Xiaoli
    Zhang, Guangjun
    2003, Beijing University of Aeronautics and Astronautics (BUAA) (29):
  • [9] A low cost, optically efficient carbon dioxide sensor based on non-dispersive infra-red (NDIR) measurement at 4.2μm
    Hodgkinson, J.
    Smith, R.
    Ho, W. O.
    Saffell, J. R.
    Tatam, R. P.
    OPTICAL SENSING AND DETECTION II, 2012, 8439
  • [10] ACCURACY OF OXYGEN AND CARBON DIOXIDE ELECTRODES
    FLENLEY, DC
    MILLAR, JS
    REES, HA
    BRITISH MEDICAL JOURNAL, 1967, 2 (5548): : 349 - &