Transportable Strontium Optical Lattice Clocks Operated Outside Laboratory at the Level of 10-18 Uncertainty

被引:49
|
作者
Ohmae, Noriaki [1 ,2 ,3 ]
Takamoto, Masao [1 ,2 ]
Takahashi, Yosuke [2 ,4 ,5 ]
Kokubun, Motohide [2 ,6 ]
Araki, Kuniya [1 ,2 ]
Hinton, Andrew [1 ]
Ushijima, Ichiro [1 ,2 ,4 ]
Muramatsu, Takashi [7 ]
Furumiya, Tetsuo [7 ]
Sakai, Yuya [7 ]
Moriya, Naoji [7 ]
Kamiya, Naohiro [7 ]
Fujii, Kazuaki [8 ]
Muramatsu, Ryuya [8 ]
Shiimado, Toshihiro [8 ]
Katori, Hidetoshi [1 ,2 ,4 ]
机构
[1] RIKEN Ctr Adv Photon, Space Time Engn Res Team, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
[2] RIKEN, Quantum Metrol Lab, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
[3] Fukuoka Univ, Dept Appl Phys, Jonan Ku, 8-19-1 Nanakuma, Fukuoka 8140180, Japan
[4] Univ Tokyo, Grad Sch Engn, Dept Appl Phys, Bunkyo Ku, 2-11-16 Yayoi, Tokyo 1138656, Japan
[5] Citizen Watch Co Ltd, 840 Simotomi, Tokorozawa, Saitama 3598511, Japan
[6] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Chuo Ku, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2525210, Japan
[7] Shimadzu Co Ltd, 3-9-4 Hikaridai, Seika, Kyoto 6190237, Japan
[8] Equos Res Co Ltd, Chiyoda Ku, 1-18-13 Sotokanda, Tokyo 1010021, Japan
关键词
optical frequency metrology; optical lattice clock; transportable atomic clock; FREQUENCY RATIO; YB;
D O I
10.1002/qute.202100015
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Transportable strontium optical lattice clocks are developed with a fractional uncertainty of 5.5 x 10(-18) for applications outside laboratories. A single clock consists of a spectroscopy chamber and two laser boxes, where all lasers are based on external cavity diode lasers with an adjustment-free, laser-welded output coupler. When this system is transported from the laboratory at RIKEN to a broadcasting tower, the instruments experience acceleration change of 4 G at maximum. However, no serious optical misalignments are found. The demonstration opens up field applications of optical atomic clocks resolving a centimeter height difference.
引用
收藏
页数:10
相关论文
共 35 条
  • [31] Frequency Comparison of Two 40Ca+ Optical Clocks with an Uncertainty at the 10-17 Level
    Huang, Y.
    Guan, H.
    Liu, P.
    Bian, W.
    Ma, L.
    Liang, K.
    Li, T.
    Gao, K.
    PHYSICAL REVIEW LETTERS, 2016, 116 (01)
  • [32] Trapping induced frequency shifts by comparison of two Sr optical lattice clocks at the 10-17 level
    Lodewyck, J.
    Westergaard, P. G.
    Lorini, L.
    Zawada, M.
    Burt, E. A.
    Gurov, M.
    Lemonde, P.
    2011 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM/EUROPEAN FREQUENCY AND TIME FORUM PROCEEDINGS, 2011, : 1 - 1
  • [33] A strontium optical lattice clock with 1 x 10-17 uncertainty and measurement of its absolute frequency
    Hobson, Richard
    Bowden, William
    Vianello, Alvise
    Silva, Alissa
    Baynham, Charles F. A.
    Margolis, Helen S.
    Baird, Patrick E. G.
    Gill, Patrick
    Hill, Ian R.
    METROLOGIA, 2020, 57 (06)
  • [34] Development of Yb Optical Lattice Clock to 10-17 Uncertainty Level and a New Clock Laser System at KRISS
    Lee, Won-Kyu
    Kim, Huidong
    Heo, Myoung-Sun
    Park, Chang Yong
    Park, Sang Eon
    Yu, Dai-Hyuk
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [35] Spin-squeezing-enhanced optical lattice clocks with 10-19-level differential frequency stability at the averaging time of 1 s
    Yu, Deshui
    Zhang, Jia
    Xia, Tongyan
    Zhang, Shougang
    Shi, Tiantian
    Chen, Jingbiao
    PHYSICAL REVIEW A, 2024, 110 (01)