ATLAS LAr calorimeter performance in LHC run 2 and electronics upgrades for next runs

被引:0
|
作者
McKay, Madalyn [1 ]
机构
[1] Southern Methodist Univ, Dallas, TX 75275 USA
关键词
ATLAS; Liquid argon; LAr; Calorimeter; Upgrade; Performance;
D O I
10.1016/j.nima.2019.05.048
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Liquid argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region vertical bar eta vertical bar < 3.2, and for hadronic and forward calorimetry in the region from vertical bar eta vertical bar= 1.5 to vertical bar eta vertical bar = 4.9. In the LHC Run 2 about 150 fb(-1) of data at a center-of-mass energy of 13 TeV have been recorded. The well calibrated and highly granular LAr Calorimeter reached its design values both in energy measurement as well as in direction resolution. Electronics developments are pursued for the trigger readout of the ATLAS LAr Calorimeter towards the Phase-I upgrade scheduled in the LHC shut-down period between December 2018 and early 2021. Trigger signals with finer spatial granularity and higher precision are needed in order to improve the identification efficiencies of electrons, photons, taus, jets and missing energy, at high background rejection rates, already at the Level-1 trigger. Following new TDAQ buffering requirements and high expected radiation doses in the pileup conditions of the high-luminosity LHC, the LAr Calorimeter electronics will be further upgraded (Phase-II) to readout the full 182,500 calorimeter cells at 40 MHz with 16 bit dynamic range. Developments of low-power preamplifiers and shapers to meet these requirements are ongoing in 130 nm CMOS. In order to digitize the analogue signals on two gains after shaping, radiation-hard, low-power 40 MHz 14-bit ADCs are developed using a SAR architecture in 65 nm CMOS. This contribution gives an overview of the detector operation, changes in the monitoring and data quality procedures, to cope with increased pileup, as well as the achieved performance. Results of ASIC developments including quality assurance and quality control (QA/QC) and radiation hardness evaluations, performances of the pre-production boards and results of the system integration tests, progress of QA/QC of final production boards are presented along with the overall system design for the Phase-I upgrade. Results of tests of the first prototypes of front-end components are presented, along with design studies on the performance of the off-detector readout system for the Phase-II upgrade.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] ATLAS computing challenges before the next LHC run
    Barberis, D.
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2016, 273 : 963 - 968
  • [32] ATLAS Liquid Argon Calorimeter Commissioning for LHC Run-3
    Furukawa, Marin
    26TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS, CHEP 2023, 2024, 295
  • [33] The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
    Abdallah, J.
    Alexa, C.
    Amaral Coutinho, Y.
    Amor Dos Santos, S. P.
    Anderson, K. J.
    Arabidze, G.
    Araque, J. P.
    Artamonov, A.
    Asquith, L.
    Astalos, R.
    Mayes, J. Backus
    Bartos, P.
    Batkova, L.
    Bertolucci, F.
    Bylund, O. Bessidskaia
    Blanco Castro, A.
    Blazek, T.
    Bohm, C.
    Boumediene, D.
    Boveia, A.
    Brown, H.
    Busato, E.
    Calkins, R.
    Calvet, D.
    Calvet, S.
    Toro, R. Camacho
    Caminal Armadans, R.
    Carli, T.
    Carvalho, J.
    Cascella, M.
    Castro, N. F.
    Cavasinni, V.
    Cerqueira, A. S.
    Chadelas, R.
    Chakraborty, D.
    Chekanov, S.
    Chen, X.
    Chikovani, L.
    Choudalakis, G.
    Cinca, D.
    Ciubancan, M.
    Clement, C.
    Cole, S.
    Constantinescu, S.
    Costin, T.
    Crouau, M.
    Crozatier, C.
    Cuciuc, C. -M.
    Da Cunha Sargedas De Sousa, M. J.
    Darmora, S.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [34] Upgrade for the ATLAS Tile Calorimeter Readout Electronics at the High Luminosity LHC
    Carrio, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 69 - 71
  • [35] Upgrade for the ATLAS Tile Calorimeter Readout Electronics at the High Luminosity LHC
    Cerqueira, A. S.
    XVTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR2012), 2012, 404
  • [36] Upgraded Trigger Readout Electronics for the ATLAS LAr Calorimeters for Future LHC Running
    Ma, Hong
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587
  • [37] Upgraded electronics of the ATLAS hadronic Tile Calorimeter for the High Luminosity LHC
    Abdallah, J.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06):
  • [38] Performance of the ATLAS Muon Trigger in Run I and Upgrades for Run II
    Kobayashi, Dai
    21ST INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP2015), PARTS 1-9, 2015, 664
  • [39] Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run2
    Cavallari, Francesca
    Rovelli, Chiara
    24TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2019), 2020, 245
  • [40] Performance evaluation of a point of load for the upgrade of the ATLAS - LAr calorimeter
    Lazzaroni, M.
    Citterio, M.
    Latorre, S.
    MEASUREMENT, 2017, 98 : 205 - 220