Radionuclide sources 57Co and 119mSn for industrial application of the Mossbauer effect

被引:3
|
作者
Rogozev, BI [1 ]
Silin, MY [1 ]
机构
[1] VG Khlopin Radium Inst, St Petersburg 194021, Russia
来源
HYPERFINE INTERACTIONS | 1998年 / 112卷 / 1-4期
关键词
Thin Film; Radionuclide; Industrial Application; Resonance Parameter; Source 57Co;
D O I
10.1023/A:1010871029400
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
In this work we tried to achieve the best gamma-resonance parameters and the reliability and the safety of the sources in connection with the wide range of its applications -from fundamental studies of physics and chemistry, to investigations of corrosion, catalysis and phase composition of samples.
引用
收藏
页码:279 / 282
页数:4
相关论文
共 50 条
  • [21] Electrolytic cell-free 57Co deposition for emission Mossbauer spectroscopy
    Zyabkin, Dmitry V.
    Prochazka, Vit
    Miglierini, Marcel
    Maslan, Miroslav
    RADIATION PHYSICS AND CHEMISTRY, 2018, 146 : 86 - 90
  • [22] Study of the conversion electron and XPS spectra of radioactive 57Co sources
    Spalek, A
    Dragoun, O
    Kovalík, A
    Yakushev, EA
    Rysavy, M
    Frána, J
    Brabec, V
    Novgorodov, AF
    Cserny, I
    Tóth, J
    Varga, D
    Köver, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 196 (3-4): : 357 - 364
  • [23] FE-57-MOSSBAUER EFFECT AND SN-119-MOSSBAUER EFFECT OF OXIDE GLASSES
    NISHIDA, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1994, 182 (02): : 451 - 476
  • [24] BIPM comparison BIPM.RI(II)-K1.Co-57 of activity measurements of the radionuclide 57Co
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2003, 40
  • [25] Cobalt(II) complexation with small biomolecules as studied by 57Co emission Mossbauer spectroscopy
    Kamnev, Alexander A.
    Perfiliev, Yurii D.
    Kulikov, Leonid A.
    Tugarova, Anna V.
    Kovacs, Krisztina
    Homonnay, Zoltan
    Kuzmann, Erno
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 172 : 77 - 82
  • [26] PREPARATION OF LINE MOSSBAUER CO-57 SOURCES
    ARTEMEV, AN
    MIRZABAB.RM
    SKLYAREV.VV
    SMIRNOV, GV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (03): : 715 - &
  • [27] Mossbauer experiments with 57Fe and 57Co in palladium hydride: Diffusional relaxation and high hydrogen concentrations
    Baier, M.
    Schneider, G.F.
    Wagner, F.E.
    Dugandzic, I.
    Bauer, H.J.
    Antonov, V.E.
    Antonova, T.E.
    Journal of Alloys and Compounds, 1997, 253-254 : 353 - 355
  • [28] Preparation of 57Co point sources for the performance evaluation of nuclear imaging instruments
    Saxena, Sanjay Kumar
    Kumar, Manoj
    Kumar, Yogendra
    Udhayakumar, J.
    Pandey, Usha
    Dash, Ashutosh
    APPLIED RADIATION AND ISOTOPES, 2013, 79 : 12 - 17
  • [29] Absence of the resonant environment effect on the half-life of the 119mSn isomer in the standard Mössbauer γ-ray source
    Bayukov Yu.D.
    Davydov A.V.
    Kartashov G.R.
    Korotkov M.M.
    Bulletin of the Russian Academy of Sciences: Physics, 2009, 73 (06) : 731 - 732
  • [30] A systematic study on the uptake of 57Co ions on amidoxime functionalized PAN-PVDF beads: preliminary studies towards fabrication of 57Co point sources
    Kumar, Manoj
    Shaikh, Samina
    Gandhi, Shyamala
    Pandey, Usha
    Kumar, Sanjukta
    Dash, Ashutosh
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 324 (02) : 879 - 885