Study of autoclaved aerated concrete masonry walls under vented gas explosions

被引:57
|
作者
Li, Zhan [1 ,2 ]
Chen, Li [1 ]
Fang, Qin [1 ]
Hao, Hong [2 ]
Zhang, Yadong [1 ]
Chen, Wensu [2 ]
Xiang, Hengbo [1 ]
Bao, Qi [1 ,3 ]
机构
[1] PLA Univ Sci & Technol, State Key Lab Disaster Prevent & Mitigat Explos &, Nanjing 210007, Jiangsu, Peoples R China
[2] Curtin Univ, Sch Civil & Mech Engn, Ctr Infrastruct Monitoring & Protect, Kent St, Bentley, WA 6102, Australia
[3] PLA 91058 Troop, Sanya 572000, Hainan, Peoples R China
基金
中国国家自然科学基金; 澳大利亚研究理事会;
关键词
Autoclaved aerated concrete (AAC); Masonry wall; Vented gas explosion; Field test; Numerical simulation; Equivalent SDOF method; MECHANISMS; PRESSURE; BEHAVIOR; DAMAGE;
D O I
10.1016/j.engstruct.2017.03.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A total of nine full-scale in-situ tests were carried out to investigate the performances of autoclaved aerated concrete (AAC) masonry walls subjected to vented gas explosions. The testing data including overpressure time histories of vented gas explosions, displacement time histories, and damage characteristics of AAC masonry walls in each test were recorded and analysed. It was found that the responses of masonry walls mainly depend on the peak value of overpressure and couple with the time history of gas explosion loads. Typical one-way or two-way flexural mode dominates the failure of AAC walls under vented gas explosions. A detailed micro model for masonry walls was developed in LS-DYNA, incorporating material parameters that were obtained from material tests. The accuracy of numerical model in predicting the responses of masonry walls was verified with the testing data. Parametric studies were conducted to explore the influences of block strength, boundary condition and wall thickness on the performances of masonry walls. The results reveal both wall thickness and boundary condition have significant influences on the response of the masonry wall while block strength has limited effect on its performance. The testing data were compared with the analytical predictions by using design code UFC 3-340-2 and equivalent single-degree-of-freedom (SDOF) methods developed respectively by Biggs and Morison. The results indicate that these predictions on one-way specimens agree well with the testing data, while the performance of two-way specimens is overestimated by using these three methods. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:444 / 460
页数:17
相关论文
共 50 条
  • [31] Seismic behavior and improvement of autoclaved aerated concrete infill walls
    Binici, Baris
    Canbay, Erdem
    Aldemir, Alper
    Demirel, Ismail Ozan
    Uzgan, Ugur
    Eryurtlu, Zafer
    Bulbul, Koray
    Yakut, Ahmet
    ENGINEERING STRUCTURES, 2019, 193 : 68 - 81
  • [32] Stress-strain characteristics of autoclaved aerated concrete masonry under varying displacement rates
    Devi, Ningombam Reena
    Zade, Nikhil P.
    Dhir, Prateek Kumar
    Sarkar, Pradip
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [33] Out-of-plane flexural behavior of autoclaved aerated concrete block masonry walls strengthened with high-ductility concrete
    Qiu, Zhengtao
    Deng, Mingke
    Zhang, Wei
    Wu, Zhiyan
    Dong, Zhifang
    Li, Tong
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 394
  • [34] CHEMICAL PROTECTION OF AERATED AUTOCLAVED CONCRETE MASONRY AGAINST WATER AND MOISTURE
    Struharova, Alena
    Dubik, Marian
    14TH CONFERENCE ON ENVIRONMENT AND MINERAL PROCESSING, PT II, 2010, : 133 - 135
  • [35] Experimental Investigation of Bond strength Autoclaved Aerated Concrete (AAC) Masonry
    Thakur, A.
    Kumar, S.
    JOURNAL OF ENGINEERING RESEARCH, 2022, 10
  • [36] Study on seismic performance of red brick walls vs. Autoclaved Aerated concrete block walls
    Kumaran, G. Deepak
    Kanna, P. G. Naresh
    Praveen, N.
    MATERIALS TODAY-PROCEEDINGS, 2022, 65 : 1623 - 1627
  • [37] Finite Element Analysis of Vertical Stress's Effect on Seismic Performance of Autoclaved Aerated Concrete Block Masonry Walls
    Wu, Huige
    Zhao, Jun
    Gu, Jie
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 1010 - +
  • [38] Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units
    Grzyb, Krzysztof
    Jasinski, Radoslaw
    MATERIALS, 2022, 15 (20)
  • [39] FEM modeling of external walls made of autoclaved aerated concrete blocks
    Pukhkal, V. A.
    Mottaeva, A. B.
    MAGAZINE OF CIVIL ENGINEERING, 2018, 81 (05): : 203 - 212
  • [40] A study of dynamic behavior of the autoclaved aerated concrete
    Belouettar, R.
    Klepaczko, J. R.
    DYMAT 2009: 9TH INTERNATIONAL CONFERENCE ON THE MECHANICAL AND PHYSICAL BEHAVIOUR OF MATERIALS UNDER DYNAMIC LOADING, VOL 1, 2009, : 503 - 509