Computer-aided analysis of 64-and 320-slice coronary computed tomography angiography: a comparison with expert human interpretation

被引:6
|
作者
Abd Alamir, Moshrik [1 ,2 ]
Noack, Pamela [1 ,3 ,4 ]
Jang, Kristine H. [1 ,5 ]
Moore, Jhanna A. [1 ,6 ]
Goldberg, Roman [7 ]
Poon, Michael [1 ,4 ,8 ,9 ,10 ,11 ,12 ]
机构
[1] Stony Brook Med, Dept Radiol, Stony Brook, NY 11794 USA
[2] Advocate Lutheran Gen Hosp, Dept Cardiol, 1775 Dempster St, Park Ridge, IL 60068 USA
[3] SUNY Stony Brook, Sch Engn, Dept Technol Soc, Stony Brook, NY 11794 USA
[4] Northwell Hlth, Lenox Hill Hosp, Dept Cardiol, New York, NY USA
[5] Cooper Univ, Dept Cardiol, Camden, NJ USA
[6] Icahn Sch Med Mt Sinai, Elmhurst, NY USA
[7] RCADIA Med Solut, Wellsley, MA USA
[8] Stony Brook Med, Dept Emergency Med, Stony Brook, NY USA
[9] Stony Brook Med, Dept Cardiol, Stony Brook, NY USA
[10] Hofstra Univ, Hofstra Northwell Sch Med, Dept Cardiol, East Garden City, NY USA
[11] Hofstra Univ, Hofstra Northwell Sch Med, Dept Radiol, East Garden City, NY USA
[12] Hofstra Univ, Hofstra Northwell Sch Med, Dept Emergency Med, East Garden City, NY USA
来源
关键词
Computer aided diagnosis; Automated results processing; Computer coronary tomography angiography; Efficiency; Triage; Emergency department; ACUTE CHEST-PAIN; CT ANGIOGRAPHY; DIAGNOSTIC PERFORMANCE; EMERGENCY-DEPARTMENT; STENOSIS DETECTION; TRIAGE; EXPERIENCE; ACCURACY;
D O I
10.1007/s10554-018-1361-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Routine use of CCTA to triage Emergency Department (ED) chest pain can reduce ED length of stay while providing accurate diagnoses. We evaluated the effectiveness of using Computer Aided Diagnosis in the triage of low to intermediate risk emergency chest pain patients with Coronary Computed Tomographic Angiography (CCTA). Using 64 and 320 slice CT scanners, we compared the diagnostic capability of computer aided diagnosis to human readers in 923 ED patients with chest pain. We calculated sensitivity, specificity, Positive Predictive Value and Negative Predictive Value for cases performed on each scanner. We calculated the area under the Receiver Operator Curve (ROC) comparing results for the two scanners to Computer Aided Diagnosis performance as compared to the human reader. We examined index and 30 Day outcomes by diagnosis for each scanner and the human reader. 60% of cases could be triaged by the computer. Sensitivity was approximately 85% for both scanners, with specificity at 50.6% for the 64 slice and at 56.5% for the 320 slice scanner (per person measures). The NPV was 97.8 and 97.1 for the 64 and 320 slice scanners, respectively. Results for the four major vessels were similar with negative predictive values ranging from 97 to 100%. The ROC for Computer Aided Diagnosis for the 64 and 320 Slice Scanners, using the human reader as the gold standard was 0.6794 and 0.7097 respectively. The index and 30 day outcomes were consistent for the human reader and Computer Aided Diagnosis interpretation. Although Computer Aided Diagnosis with CCTA cannot serve completely as a substitute for human reading, it offers excellent potential as a triage tool in busy EDs.
引用
收藏
页码:1473 / 1483
页数:11
相关论文
共 50 条
  • [21] Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography A Flawed Comparison
    Nicol, Edward D.
    Stirrup, James
    Padley, Simon P. G.
    Rubens, Michael B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (19) : 1824 - 1825
  • [22] Detection of coronary artery anomalies in Chinese adults using 320-slice computed tomography
    Tang, Xixiang
    Chen, Yanming
    Peng, Long
    Dong, Ruimin
    Luo, Yanting
    Li, Suhua
    Liu, Jinlai
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C132 - C133
  • [23] The contrast of radiation dose with three scan modes in 320-slice dynamic volume computed tomography angiography compared with selective coronary angiography
    Liu, Xuelian
    Liang, Limin
    Lian, Xianhui
    Hao, Baoshun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C261 - C261
  • [24] Comparison of 64-Slice Computed Tomography Angiography and Selective Angiography for Coronary Artery Bypass Grafts
    Xu, Ze-Sheng
    Zhang, Zhi-Ying
    Geng, Tao
    CIRCULATION, 2010, 122 (02) : E204 - E204
  • [25] Effective radiation dose of cardiac computer tomography angiography. A comparison between 64-and 16-slice technology
    Hausleiter, J.
    Meyer, T. S.
    Hadamitzky, M.
    Martinoff, S.
    Schoemig, A.
    EUROPEAN HEART JOURNAL, 2005, 26 : 533 - 534
  • [26] Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography
    Meijboom, W. Bob
    Meijs, Matthijs F. L.
    Schuijf, Joanne D.
    Cramer, Maarten J.
    Mollet, Nico R.
    van Mieghem, Carlos A. G.
    Nieman, Koen
    van Werkhoven, Jacob M.
    Pundziute, Gabija
    Weustink, Annick C.
    de Vos, Alexander M.
    Pugliese, Francesca
    Rensing, Benno
    Jukema, J. Wouter
    Bax, Jeroen J.
    Prokop, Mathias
    Doevendans, Pieter A.
    Hunink, Myriam G. M.
    Krestin, Gabriel P.
    de Feyter, Pim J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (25) : 2135 - 2144
  • [27] Diagnostic accuracy of 320-slice dynamic volume computed tomography angiography for detection of coronary artery stenosis in patients with atrial fibrillation
    Liu, Xuelian
    Liang, Limin
    Liang, Xianhui
    Hao, Baoshun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C263 - C263
  • [28] Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography A Flawed Comparison Reply
    Nissen, Steven E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (19) : 1826 - 1827
  • [29] Assessment of coronary bifurcation lesions with 64-slice computed tomography coronary angiography
    Van Mieghem, C.
    Thury, A.
    Meijboom, W. B.
    Cademartiri, F.
    Mollet, N. R.
    Krestin, G. P.
    Serruys, P. W.
    De Feyter, P. J.
    EUROPEAN HEART JOURNAL, 2006, 27 : 509 - 509
  • [30] Assessment of coronary bifurcation lesions with 64-slice computed tomography coronary angiography
    Van Mieghem, Carlos A.
    Meijboom, Willem B.
    Cademartiri, Filippo
    Mollet, Nico R.
    Weustink, Annick
    Krestin, Gabriel P.
    Serruys, Patrick W.
    de Feyler, Pim J.
    CIRCULATION, 2006, 114 (18) : 819 - 819