Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer

被引:23
|
作者
Su, Lin [1 ]
Iordachita, Iulian [2 ]
Zhang, Yin [1 ]
Lee, Junghoon [1 ]
Ng, Sook Kien [1 ]
Jackson, Juan [1 ]
Hooker, Ted [1 ]
Wong, John [1 ]
Herman, Joseph M. [1 ]
Sen, H. Tutkun [3 ]
Kazanzides, Peter [3 ]
Bell, Muyinatu A. Lediju [3 ]
Yang, Chen [1 ,4 ]
Ding, Kai [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[4] Zhejiang Canc Hosp, Dept Ultrasound, Hangzhou, Zhejiang, Peoples R China
来源
基金
美国国家卫生研究院;
关键词
intrafraction; pancreas; SBRT; ultrasound; INTRAFRACTIONAL MOTION; FIDUCIAL MARKERS; RADIOTHERAPY; TRACKING; GUIDANCE; ALGORITHM;
D O I
10.1002/acm2.12100
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Stereotactic body radiation therapy (SBRT) allows for high radiation doses to be delivered to the pancreatic tumors with limited toxicity. Nevertheless, the respiratory motion of the pancreas introduces major uncertainty during SBRT. Ultrasound imaging is a non-ionizing, non-invasive, and real-time technique for intrafraction monitoring. A configuration is not available to place the ultrasound probe during pancreas SBRT for monitoring. Methods and Materials: An arm-bridge system was designed and built. A CT scan of the bridge-held ultrasound probe was acquired and fused to ten previously treated pancreatic SBRT patient CTs as virtual simulation CTs. Both step-and-shoot intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning were performed on virtual simulation CT. The accuracy of our tracking algorithm was evaluated by programmed motion phantom with simulated breath-hold 3D movement. An IRB-approved volunteer study was also performed to evaluate feasibility of system setup. Three healthy subjects underwent the same patient setup required for pancreas SBRT with active breath control (ABC). 4D ultrasound images were acquired for monitoring. Ten breath-hold cycles were monitored for both phantom and volunteers. For the phantom study, the target motion tracked by ultrasound was compared with motion tracked by the infrared camera. For the volunteer study, the reproducibility of ABC breath-hold was assessed. Results: The volunteer study results showed that the arm-bridge system allows placement of an ultrasound probe. The ultrasound monitoring showed less than 2mm reproducibility of ABC breath-hold in healthy volunteers. The phantom monitoring accuracy is 0.14 +/- 0.08 mm, 0.04 +/- 0.1 mm, and 0.25 +/- 0.09 mm in three directions. On dosimetry part, 100% of virtual simulation plans passed protocol criteria. Conclusions: Our ultrasound system can be potentially used for real-time monitoring during pancreas SBRT without compromising planning quality. The phantom study showed high monitoring accuracy of the system, and the volunteer study showed feasibility of the clinical workflow.
引用
收藏
页码:84 / 96
页数:13
相关论文
共 50 条
  • [11] Individualized Gated Stereotactic Body Radiation Therapy for Pancreatic Cancer
    Peguret, N.
    Rodrigues, J. Soares
    Germond, J.
    De Bari, B.
    Bourhis, J.
    Ozsahin, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S357 - S358
  • [12] Stereotactic body radiation therapy for locally advanced pancreatic cancer
    Vera Merino, M.
    Angel Schutte, D.
    Giraudo, A.
    Suarez Villasmil, L.
    Almada, M.
    Venencia, D.
    Zunino, S.
    ANNALS OF ONCOLOGY, 2020, 31 : S96 - S96
  • [13] Incorporating stereotactic body radiation therapy for inoperable pancreatic cancer
    Lukez, Alexander
    Hasler, Jill S.
    Reddy, Sanjay S.
    Dotan, Efrat
    Astsaturov, Igor A.
    Lynch, Shannon M.
    Sorice, Kristen A.
    Meyer, Joshua E.
    JOURNAL OF CLINICAL ONCOLOGY, 2024, 42 (3_SUPPL) : 656 - 656
  • [14] Stereotactic body radiation therapy for locally advanced pancreatic cancer
    Jung, Jinhong
    Yoon, Sang Min
    Park, Jin-hong
    Seo, Dong-Wan
    Lee, Sang Soo
    Kim, Myung-Hwan
    Lee, Sung Koo
    Park, Do Hyun
    Song, Tae Jun
    Ryoo, Baek-Yeol
    Chang, Heung-Moon
    Kim, Kyu-pyo
    Yoo, Changhoon
    Jeong, Jae Ho
    Kim, Song Cheol
    Hwang, Dae Wook
    Lee, Jae Hoon
    Song, Ki Byung
    Jo, Yoon Young
    Park, Jongmoo
    Kim, Jong Hoon
    PLOS ONE, 2019, 14 (04):
  • [15] A current perspective on stereotactic body radiation therapy for pancreatic cancer
    Hong, Julian C.
    Czito, Brian G.
    Willett, Christopher G.
    Palta, Manisha
    ONCOTARGETS AND THERAPY, 2016, 9 : 6733 - 6739
  • [16] Feasibility of Vascular Matching for Image Guided Pancreatic Stereotactic Body Radiation Therapy
    Perni, S.
    Chin, C.
    Yan, P.
    Yanagihara, T. K.
    Horowitz, D. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E182 - E182
  • [17] Endoscopic Ultrasound-Guided Fiducial Placement for Stereotactic Body Radiation Therapy in Patients with Pancreatic Cancer
    Cazacu, Irina M.
    Singh, Ben S.
    Martin-Paulpeter, Rachael M.
    Beddar, Sam
    Chun, Stephen
    Holliday, Emma B.
    Koong, Albert C.
    Das, Prajnan
    Koay, Eugene J.
    Taniguchi, Cullen
    Herman, Joseph M.
    Bhutani, Manoop S.
    CANCERS, 2023, 15 (22)
  • [18] Scanning Beam Stereotactic Body Proton Therapy (SBPT) for Pancreatic Cancer: A Dosimetric Feasibility Study
    Sio, T. T.
    Beltran, C. J.
    Ashman, J. B.
    Wurgler, S. K.
    Hoeft, K. A.
    Miller, R. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S185 - S185
  • [19] Stereotactic Body Radiation Therapy for Pancreatic Adenocarcinoma
    Yanagihara, T.
    Jani, A.
    Oberstein, P. E.
    Chabot, J. A.
    Sherman, W. H.
    Schrope, B. A.
    Woo, Y.
    Hecht, E. M.
    Arindam, R.
    Chu, A.
    Salah, K.
    Addeo, D.
    Horowitz, D. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E140 - E140
  • [20] Integration of Stereotactic Body Radiation Therapy into the Multidisciplinary Management of Pancreatic Cancer
    Rosati, Lauren M.
    Kumar, Rachit
    Herman, Joseph M.
    SEMINARS IN RADIATION ONCOLOGY, 2017, 27 (03) : 256 - 267