Reliability and validity of three isometric back extensor strength assessments with different test postures

被引:11
|
作者
Yang, Sen [1 ]
Wu, Wenjie [1 ]
Zhang, Chengmin [1 ]
Wang, Donggui [1 ]
Chen, Can [1 ]
Tang, Yong [1 ]
Li, Kai [1 ]
Xu, Jianzhong [1 ]
Luo, Fei [1 ]
机构
[1] Third Mil Med Univ, Southwest Hosp, Dept Orthopaed, 30 Gaotanyan St, Chongqing 400038, Peoples R China
关键词
Back extensor; isometric strength; postures; dynamometer; reliability; validity; HAND-HELD DYNAMOMETRY; MUSCLE STRENGTH; TRUNK STRENGTH; ENDURANCE; WOMEN; PAIN; HIP;
D O I
10.1177/0300060519885268
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective To compare the test-retest reliability and validity of three simple maximal isometric back extensor strength (BES) assessment protocols with different test postures, and to recommend an optimal clinical protocol to quantify BES. Methods Asymptomatic adults, aged over 45 years, were assessed for maximal isometric BES using external fixation of dynamometers, with the subject in standing, prone and sitting positions, respectively. Measurements were repeated at a one-week interval to examine test-retest reliability. Validation was performed by comparing with results obtained from isokinetic dynamometer assessments. Results Out of a total of 60 included participants, intra-class correlation coefficients (ICC) were 0.92, 0.93 and 0.90 in standing, prone and sitting positions, respectively. Correlation analyses revealed acceptable convergent validity in the standing and prone position (r = 0.50 and 0.54, respectively), whereas tests conducted in the sitting position showed a relatively low validity (r = 0.32). Among the three protocols, measurement error was lowest in the prone position. Conclusions Maximal isometric BES assessment in the prone position was shown to be the most reliable and valid protocol, and may be considered the preferred option for assessing BES in clinical practice.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength
    Neil, Sarah E.
    Myring, Alec
    Peeters, Mon Jef
    Pirie, Ian
    Jacobs, Rachel
    Hunt, Michael A.
    Garland, S. Jayne
    Campbell, Kristin L.
    PHYSIOTHERAPY THEORY AND PRACTICE, 2013, 29 (08) : 639 - 647
  • [2] The Reliability and Validity of a Novel Ankle Isometric Plantar Flexion Strength Test
    Kobayashi, Takumi
    Mizota, Takeshi
    Kon, Kana
    Kasaya, Miku
    Miyabe, Shogo
    Shindome, Tomo
    Ishibashi, Kousuke
    JOURNAL OF SPORT REHABILITATION, 2022, 31 (05) : 529 - 535
  • [3] Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study
    Kim, Won Kuel
    Kim, Don-Kyu
    Seo, Kyung Mook
    Kang, Si Hyun
    ANNALS OF REHABILITATION MEDICINE-ARM, 2014, 38 (01): : 84 - 93
  • [4] Validity and Reliability of the Isometric Prone Bench Pull Test
    Lum, Danny
    Aziz, Luqman
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2020, 41 (08) : 520 - 527
  • [5] Validity and reliability of Squegg device in measuring isometric handgrip strength
    Bairapareddy, K. C.
    Khaleel, A.
    Akbar, S.
    Maherban, H.
    Mehdiyeva, F.
    Rasti, F.
    Tamim, M.
    Abdelbasset, W. K.
    Ezzat, W.
    Reddy, R. S.
    Tedla, J. S.
    Ramakrshnan, S.
    Hussein, R. S.
    Alaparthi, G. K.
    Elsayed, S. H.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (21) : 10247 - 10254
  • [6] Reliability and validity of isokinetic and isometric strength testing: a systematic review
    Knauer, Miriam
    Schroeder, Jan
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2024,
  • [7] Novel Assessment of Isometric Hip Extensor Function: Reliability, Joint Angle Sensitivity, and Concurrent Validity
    Goodwin, Jon E.
    Bull, Anthony M. J.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2022, 36 (10) : 2762 - 2770
  • [8] Reliability and validity of a new device to measure isometric strength in polyarticular exercises
    Verdera, F
    Champavier, L
    Schmidt, C
    Bermon, S
    Marconnet, P
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 1999, 39 (02): : 113 - 119
  • [9] The supine hip extensor manual muscle test: A reliability and validity study
    Perry, J
    Weiss, WB
    Burnfield, JM
    Gronley, JK
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (08): : 1345 - 1350
  • [10] Reliability and validity of surface EMG assessments combined with isometric muscle strength testing in patients with abdominal rectus diastasis and asymptomatic controls
    Swedenhammar, E.
    Wahlstrom, O.
    Brandt, J. D.
    Strigard, K.
    Hager, C.
    Stark, B.
    Nyberg, A.
    HERNIA, 2024, 28 (04) : 1413 - 1426