Validated simulation for LYSO:Ce scintillator based PET detector modules built on fully digital SiPM arrays

被引:4
|
作者
Jatekos, B. [1 ]
Gasparini, L. [2 ]
Lorincz, E. [1 ]
Erdei, G. [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Atom Phys, Budafoki Ut 8, H-1111 Budapest, Hungary
[2] Fdn Bruno Kessler, Ctr Mat & Microsyst, Integrated Radiat & Image Sensors, Via Sommar 18, I-38123 Trento, Italy
来源
关键词
Simulation methods and programs; Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators); Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Gamma detectors (scintillators; CZT; HPG; HgI etc); CRYSTAL; RESOLUTION; OUTPUT;
D O I
10.1088/1748-0221/11/03/P03028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the recent years new digital photon counter devices (also known as silicon photomultipliers, SiPMs) were designed and manufactured to be used specifically in positron emission tomography (PET) scanners. These finely pixelated devices opened new opportunities in PET detector development, hence their application with monolithic scintillator crystals now are of particular interest. We worked out a simulation tool and a corresponding validation method to assist the optimization and characterization of such PET detector modules. During our work we concentrated on the simulation of SPADnet sensors and the LYSO:Ce scintillator material. Validation of our algorithms combines measurements and simulations performed on UV-excited detector modules. In this paper we describe the operation of the simulation method in detail and present the validation scheme for two demonstrative PET detector-like modules: one built of a scintillator with black-painted faces and another with polished faces. By evaluating the results we show that the shape deviation of the average light distributions is lower than 13%, and the pixel count statistics follow Poisson distribution for both measurement and simulation. The calculated total count values have less than 10% deviation from the measured ones.
引用
下载
收藏
页数:28
相关论文
共 37 条
  • [1] SiPM based PET Detector Modules with Air-Gapped Pixelated LYSO
    Wei, Qingyang
    Wang, Shi
    Dai, Tiantian
    Li, Dehong
    Xu, Tianpeng
    Jiang, Nianming
    He, Feng
    Jin, Yongjie
    Ma, Tianyu
    Liu, Yaqiang
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] Development of PET systems using SiPM based digital PET detector modules
    Hua, Yuexuan
    Kao, Chien-Min
    Liu, Tong
    Gu, Shuguo
    Chen, Fang
    Kim, Heejong
    Xie, Qingguo
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [3] Design and Evaluation of an FPGA-ADC Prototype for the PET Detector Based on LYSO Crystals and SiPM Arrays
    Ma, Cong
    Dong, Xue
    Yu, Li
    Wang, Wubin
    Zhao, Xiaokun
    Li, Xing
    Huang, Zhenqing
    Wu, Guocheng
    Lu, Lei
    Chen, Hansheng
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (01) : 33 - 41
  • [4] Use of single photon counting detector arrays in combined PET/MR: Characterization of LYSO-SiPM detector modules and comparison with a LSO-APD detector
    Spanoudaki, V. C.
    Mann, A. B.
    Otte, A. N.
    Konorov, I.
    Torres-Espallardo, I.
    Paul, S.
    Ziegler, S. I.
    JOURNAL OF INSTRUMENTATION, 2007, 2
  • [5] Integrated optical and nuclear simulation of a monolithic LYSO:Ce based PET detector module
    Jatekos, B.
    Patay, G.
    Lorincz, E.
    Erdei, G.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [6] Performance of a SiPM based semi-monolithic scintillator PET detector
    Zhang, Xianming
    Wang, Xiaohui
    Ren, Ning
    Kuang, Zhonghua
    Deng, Xinhan
    Fu, Xin
    Wu, San
    Sang, Ziru
    Hu, Zhanli
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Yang, Yongfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (19): : 7889 - 7904
  • [7] A novel, SiPM-array-based, monolithic scintillator detector for PET
    Schaart, Dennis R.
    van Dam, Herman T.
    Seifert, Stefan
    Vinke, Ruud
    Dendooven, Peter
    Lohner, Herbert
    Beekman, Freek J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (11): : 3501 - 3512
  • [8] Development of a Preclinical PET System Based on Pixelated LYSO Crystals and SiPM Arrays
    Zeraatkar, Navid
    Sajedi, Salar
    Kaviani, Sanaz
    Taheri, Mohsen
    Khanmohammadi, Hadi
    Sarkar, Saeed
    Ay, Mohammad Reza
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [9] Compact detector modules for high resolution PET Imaging with LYSO and avalanche photodiode arrays
    Clajus, M
    Cajipe, VB
    Calderwood, RF
    Cherry, SR
    Hayakawa, S
    Tümer, TO
    Yossifor, O
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2890 - 2892
  • [10] High probability crystal pin identification in scintillator matrix-based PET detector with a prototype digital SiPM
    Jatekos, B.
    Lorincz, E.
    Ujhelyi, F.
    Erdei, G.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,