Stack effects in tall building fires: a case study of Taiwan old apartment fire

被引:3
|
作者
Huang, HongSheng [1 ]
Lin, ChingYuan [1 ]
Wang, ShiuanCheng [2 ]
Su, ChungHwei [3 ]
Chen, LiPeng [3 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Architecture, Taipei 10607, Taiwan
[2] Chia Nan Univ Pharm & Sci, Dept Publ Safety & Fire Sci, Tainan 71710, Taiwan
[3] Natl Kaohsiung Univ Sci & Technol, Dept Safety Hlth & Environm Engn, 1 Daxue Rd, Kaohsiung 82445, Taiwan
关键词
TUNNEL; TEMPERATURE; TAINAN;
D O I
10.1038/s41598-022-13118-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Tainan, a city that prospered early in Taiwan, has a hot and humid atmosphere. Hence, the grilled doors in numerous old buildings for ventilation and lighting to conserve energy. This study analyzed a fire incident that occurred during the late night of March 17, 2019 in a 38-year-old dwelling, where three residents were severely covered with soot. The site investigation showed that eight staircases lead to the same basement, which apparently created a stack effect and a makeup air phenomenon. Numerical simulations have been performed in this study to reconstruct the fire scene, whose results were consistent with the actual fire scene. In particular, the results showed that some staircases in the fire were blackened by smoke, while others acted as makeup air inlets. The temperature at the households' doors on all floors of Staircase 2, which was closest to the fire, exceeded 60 degrees C after four minutes. Furthermore, two immediately feasible improvement strategies according to the control volume theory of fluid mechanics were proposed in this study. Firstly, changing the grilled doors in the basement to a closed flat door style could effectively prevent smoke from flowing up in the staircases. Secondly, residents may consider closing the windows of the stairs at night to improve fire safety. The results showed that the chimney effect can be significantly reduced. These improvements could be a reference for other old dwellings to enhance their fire safety.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Investigating the energy use in an Australian building: A case study of a west-facing apartment in Sydney
    Owolabi, Abdulhameed Babatunde
    Suh, Dongjun
    Pignatta, Gloria
    AIN SHAMS ENGINEERING JOURNAL, 2023, 14 (08)
  • [42] Effects of fire on precast members: A case study
    Kose, Mehmet M.
    Temiz, Huseyin
    Binici, Hanifi
    ENGINEERING FAILURE ANALYSIS, 2006, 13 (08) : 1191 - 1201
  • [43] Analysis of a high-tech plant fire happened in Taiwan: A case study
    Hsieh, Chih-Chiang
    Shu, Chi-Min
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2024, 92
  • [44] Optimal human resource allocation model: A case study of Taiwan fire service
    Lan, Chun-Hsiung
    Chuang, Liang-Lun
    Chen, Yung-Fang
    JOURNAL OF STATISTICS & MANAGEMENT SYSTEMS, 2011, 14 (01): : 187 - 216
  • [45] Digital Preservation of Historic Building - A case study of the historic building Wuri Municipal Government Building in central Taiwan
    Li, Chi-Hua
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ELECTRONIC SCIENCE AND AUTOMATION CONTROL, 2015, 20 : 40 - 43
  • [46] Case Study and Computational Modelling of the Impact of Fire Retardant on Fire Spread for Metal Building Insulation
    Senez, Peter
    Milford, Adrian
    Calder, Keith
    FIRE TECHNOLOGY, 2016, 52 (06) : 1983 - 2003
  • [47] Design for improving pedestrian wind comfort: a case study on a courtyard around a tall building
    Serteser, N.
    Karadag, I.
    ARCHITECTURAL SCIENCE REVIEW, 2018, 61 (06) : 492 - 499
  • [48] A case study of the structural responses of a tall building in Singapore subjected to close-in detonations
    Li, Bing
    Pan, Tso-Chien
    Nair, Anand
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (02): : 223 - 246
  • [49] Case Study and Computational Modelling of the Impact of Fire Retardant on Fire Spread for Metal Building Insulation
    Peter Senez
    Adrian Milford
    Keith Calder
    Fire Technology, 2016, 52 : 1983 - 2003
  • [50] MONITORING THE DAMAGE AND AIR POLLUTANTS AFTER FOREST FIRES: THE CASE STUDY OF VATERA FIRE IN LESVOS
    Akyurek, Ozer
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2023, 22 (06): : 989 - 998