Square wave voltammetry versus electrochemical impedance spectroscopy as a rapid detection technique at electrochemical immunosensors

被引:86
|
作者
Liu, Xiaoqiang [1 ]
Duckworth, Paul A. [2 ]
Wong, Danny K. Y. [1 ]
机构
[1] Macquarie Univ, Dept Chem & Biomol Sci, Sydney, NSW 2109, Australia
[2] eDAQ Pty Ltd, Denistone E, NSW 2112, Australia
来源
BIOSENSORS & BIOELECTRONICS | 2010年 / 25卷 / 06期
关键词
Square wave voltammetry; Electrochemical impedance spectroscopy; Label-free immunosensors; Thiolated Protein G-scaffold; Estradiol detection; PROSTATE-SPECIFIC ANTIGEN; LABEL-FREE IMMUNOSENSOR; THIOLATED PROTEIN-G; CARBON NANOTUBE; ANTIBODY; ARRAY; GOLD; NANOPARTICLES; PICOGRAM; BINDING;
D O I
10.1016/j.bios.2009.10.047
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Square wave voltammetry (SWV) was compared to electrochemical impedance spectroscopy (EIS) in developing a label-free electrochemical immunosensor for the hormone estradiol. The immunosensor consists of a Au electrode anchored with a Au nanoparticle vertical bar thiolated Protein G-scaffold to facilitate immobilisation of an enhanced quantity of an almost uprightly aligned anti-estradiol capture antibody. Competitive immunoassays between an estradiol-bovine saline albumin complex and free estradiol in a sample were then promoted at the immunosensor. Next, SWV and EIS of [Fe(CN)(6)](3-/4-) were sequentially-conducted at the immunosensor. SWV yielded familiar peak-shaped voltammograms with the peak currents readily employable in establishing calibration. A dynamic range up to similar to 1200 pg mL(-1) and a detection limit of 18 pg mL(-1) estradiol were achieved. In EIS, an electron transfer resistance estimated from the Nyquist plots was used in the calibration experiments. A comparable dynamic range up to similar to 1000 pg mL(-1) and a detection limit of 26 pg mL(-1) estradiol were obtained. However, a significantly 10 times longer analysis time and substantial effort were required to complete the EIS determinations relative to SWV. Moreover, a large amount of EIS data involving phase angle was collected but ignored because they would not contribute any useful information to quantitative determination. Overall, SWV was determined to be a more rapid, efficient, effective and low cost detection technique than EIS at label-free electrochemical immunosensors. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1467 / 1473
页数:7
相关论文
共 50 条
  • [31] Sinusoidal voltammetry: a frequency based electrochemical detection technique
    Brazill, SA
    Bender, SE
    Hebert, NE
    Cullison, JK
    Kristensen, EW
    Kuhr, WG
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 531 (02): : 119 - 132
  • [32] Electrochemical Impedance Spectroscopy for Specific Detection of Enterovirus
    Mejri, M. B.
    Marrakchi, M.
    Baccar, H.
    Helali, S.
    Aouni, M.
    Hamdi, M.
    Jaffrezic-Renault, N.
    Abdelghani, A.
    SENSOR LETTERS, 2009, 7 (05) : 896 - 899
  • [33] Electrochemical studies and square wave adsorptive stripping voltammetry of the antidepressant fluoxetine
    da Silva, AMSR
    Lima, JC
    Teles, MTO
    Brett, AMO
    TALANTA, 1999, 49 (03) : 611 - 617
  • [34] Integrated Square Wave Voltammetry Redox Sensor System for Electrochemical Analysis
    Lim, Byounghyun
    Futagawa, Masato
    Takahashi, Sou
    Dasai, Fumihiro
    Ishida, Makoto
    Sawada, Kazuaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2013, 52 (11)
  • [35] Detection of Listeria monocytogenes by electrochemical impedance spectroscopy
    Radhakrishnan, Rajeswaran
    Dawson, Karen
    Rogers, Shane
    Suni, Ian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [36] DETECTION OF PITTING WITH ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY - REPLY
    MANSFELD, F
    SHIH, H
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1990, 137 (01) : 352 - 352
  • [37] Electrochemical characterization of simvastatin by abrasive stripping and square-wave voltammetry
    Komorsky-Lovric, Sebojka
    Nigovic, Biljana
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 593 (1-2) : 125 - 130
  • [38] Electrochemical Determination of Sunscreens Agents in Cosmetic Using Square Wave Voltammetry
    Lopes Neves, Raiane Aparecida
    Araujo, Fausto Moreira
    Pacheco, Felipe Siqueira
    Azevedo, Gustavo Chevitarese
    Costa Matos, Maria Auxiliadora
    Matos, Renato Camargo
    ELECTROANALYSIS, 2019, 31 (03) : 496 - 503
  • [39] Electrochemical Characterization of Epigallocatechin Gallate Using Square-Wave Voltammetry
    Novak, Ivana
    Seruga, Marijan
    Komorsky-Lovric, Sebojka
    ELECTROANALYSIS, 2009, 21 (09) : 1019 - 1025
  • [40] Electrochemical impedance spectroscopy and cyclic voltammetry of ferrocene in acetonitrile/acetone system
    Nikos G. Tsierkezos
    Uwe Ritter
    Journal of Applied Electrochemistry, 2010, 40 : 409 - 417