Measurement of blood perfusion in the dental pulp with laser Doppler flowmetry

被引:16
|
作者
Firestone, AR
Wheatley, AM
Thüer, UW
机构
[1] Univ Bern, Dept Orthodont, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept Visceral & Transplantat Surg, CH-3010 Bern, Switzerland
关键词
laser Doppler flowmetry; pulpal blood flow; trauma;
D O I
10.1159/000179244
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The reproducibility of laser Doppler flowmetry (LDF) in measuring the perfusion of the dental pulp was investigated. A second aim was to establish if the LDF signal from the dental pulp can be influenced by physiological stimuli, e.g. postural changes. a third aim was to apply the technique to clinical measurements of pulp perfusion in patients undergoing orthodontic therapy. A custom splint to position the probe was fabricated for 10 subjects, and measurements of pulpal perfusion in the maxillary six anterior teeth were repeated on eight occasions with the subject seated, Further, measurements of the dental pulp perfusion in one tooth were repeated with the subject in a standing and supine position, Mean perfusion (arbitrary perfusion units) for individual teeth varied from 2.7 for a central incisor to 15.5 for a lateral incisor, Perfusion was greatest for lateral incisors and least for central incisors. Pulpal perfusion was significantly higher in a supine than in a standing or sitting position. Initial clinical experience with LDF encourages further investigation of its potential as a diagnostic tool for determining pulp vitality. Preliminary experimental results suggest that LDF will be a valuable source indicating pulpal response to orthodontic therapy with fixed appliances.
引用
收藏
页码:298 / 304
页数:7
相关论文
共 50 条
  • [21] BLOOD-FLOW CHANGES IN THE DENTAL-PULP MEASURED SIMULTANEOUSLY BY LASER DOPPLER FLOWMETRY AND I-125 CLEARANCE
    EDWALL, B
    GAZELIUS, B
    BERG, JO
    EDWALL, L
    HELLANDER, K
    OLGART, L
    ACTA PHYSIOLOGICA SCANDINAVICA, 1987, 129 (03): : A42 - A42
  • [22] ASSESSMENT OF HUMAN MUSCLE BLOOD PERFUSION WITH SINGLE-FIBER LASER DOPPLER FLOWMETRY
    KVERNEBO, K
    STAXRUD, LE
    SALERUD, EG
    MICROVASCULAR RESEARCH, 1990, 39 (03) : 376 - 385
  • [23] Measurement depth and volume in laser Doppler flowmetry
    Fredriksson, Ingemar
    Larsson, Marcus
    Stromberg, Tomas
    MICROVASCULAR RESEARCH, 2009, 78 (01) : 4 - 13
  • [24] Blood Perfusion Values of Laser Speckle Contrast Imaging and Laser Doppler Flowmetry: Is a Direct Comparison Possible?
    Binzoni, Tiziano
    Humeau-Heurtier, Anne
    Abraham, Pierre
    Mahe, Guillaume
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (05) : 1259 - 1265
  • [25] MEASUREMENT OF MUSCLE SURFACE CAPILLARY BLOOD-FLOW BY LASER DOPPLER FLOWMETRY
    NORMAN, WM
    COURT, MH
    DODMAN, NH
    PIPERS, FS
    VETERINARY SURGERY, 1992, 21 (06) : 491 - 493
  • [26] CALIBRATION OF LASER-DOPPLER FLOWMETRY FOR MEASUREMENT OF GINGIVAL BLOOD-FLOW
    SASANO, T
    SHOJI, N
    KURIWADA, S
    SANJO, D
    JOURNAL OF PERIODONTAL RESEARCH, 1995, 30 (04) : 298 - 301
  • [27] Measurement of rectal blood flow by laser Doppler flowmetry in inflammatory bowel disease
    Guslandi, M
    Sorghi, S
    Polli, D
    Tittobello, A
    HEPATO-GASTROENTEROLOGY, 1998, 45 (20) : 445 - 446
  • [28] LASER-DOPPLER FLOWMETRY AS A MEASUREMENT OF COLONIC MUCOSAL BLOOD-FLOW
    HOLTZMULLER, K
    DUNKLEBERG, J
    MAYDONOVITCH, CL
    WONG, RKH
    GASTROINTESTINAL ENDOSCOPY, 1989, 35 (02) : 181 - 181
  • [29] Measurement of pulp blood flow rates in maxillary anterior teeth using ultrasound Doppler flowmetry
    Cho, Y. -W.
    Park, S. -H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (12) : 1175 - 1180
  • [30] Coherence effects in laser Doppler blood flowmetry
    Steenbergen, W
    vanStratum, M
    deMul, F
    Greve, J
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS AND ADVANCED TECHNIQUES IN ANALYTICAL CYTOLOGY, PROCEEDINGS OF, 1997, 2982 : 6 - 17