Size-exclusion liquid chromatography of poly(N-vinylformamide)s in aqueous solutions

被引:3
|
作者
Krasikov, V. D. [1 ]
Gorshkov, N. I. [1 ]
Malakhova, I. I. [1 ]
Egorova, O. S. [1 ]
Pokhvoshchev, Yu. V. [1 ]
机构
[1] Russian Acad Sci, Inst Macromol Cpds, Bolshoi Pr 31, St Petersburg 199004, Russia
关键词
size-exclusion chromatography; velocity sedimentation; polyelectrolytes; poly(N-vinylamide)s; hydrodynamic sizes; intrinsic viscosity; molecular-weight characteristics; N-VINYLFORMAMIDE; COPOLYMERS; MOLECULES; POLYMERS;
D O I
10.1134/S1061934817040050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The exclusion mechanism of the separation of poly(N-vinylformamide) and its derivatives with a cysteamine terminal group in gel permeation chromatography implemented by the suppression of polyelectrolyte swelling and the electroexclusion of macromolecules was established by the transport analytical methods of molecular hydrodynamics (HPLC, velocity sedimentation, and intrinsic viscosity). Based on an analysis of the hydrodynamic characteristics and molecular weights of polymer fractions determined by velocity sedimentation, it was found that the molecular characteristics and polydispersity of the water-soluble poly(N-vinylamide) s of aliphatic carboxylic acids and their derivatives can be calculated with the use of the Benoit universal calibration dependence.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 50 条
  • [41] MECHANISM OF SIZE-EXCLUSION CHROMATOGRAPHY .1. ROLE OF CONVECTION AND OBSTRUCTED DIFFUSION IN SIZE-EXCLUSION CHROMATOGRAPHY
    POTSCHKA, M
    JOURNAL OF CHROMATOGRAPHY, 1993, 648 (01): : 41 - 69
  • [42] Study on the acidic hydrolysis process of poly(n-vinylformamide/ acrylonitrile) fiber
    Chen, Quan
    Dong, Liang
    Ye, Guangdou
    Xu, Jianjun
    Journal of Applied Polymer Science, 2008, 109 (04): : 2636 - 2642
  • [43] SIZE-EXCLUSION CHROMATOGRAPHY OF CATIONIC AND ANIONIC POLYELECTROLYTES IN AQUEOUS-MEDIA
    KUHN, A
    FORSTER, S
    LOSCH, R
    ROMMELFANGER, M
    ROSENAUER, C
    SCHMIDT, M
    MAKROMOLEKULARE CHEMIE-RAPID COMMUNICATIONS, 1993, 14 (07): : 433 - 438
  • [44] SIZE-EXCLUSION CHROMATOGRAPHY AND SIZE-EXCLUSION CHROMATOGRAPHY FOURIER TRANSFORM INFRARED SPECTROMETRY OF REACTING ORGANOFUNCTIONAL TRIALKOXYSILANES
    MILLER, JD
    ISHIDA, H
    ANALYTICAL CHEMISTRY, 1985, 57 (01) : 283 - 288
  • [45] Study on the acidic hydrolysis process of poly(N-vinylformamide/acrylonitrile) fiber
    Chen, Quan
    Dong, Liang
    Ye, Guangdou
    Xu, Jianjun
    JOURNAL OF APPLIED POLYMER SCIENCE, 2008, 109 (04) : 2636 - 2642
  • [46] SIZE-EXCLUSION CHROMATOGRAPHY OF CATIONIC POLY-ELECTROLYTES ON SUPEROSE GEL
    STREGE, MA
    DUBIN, PL
    JOURNAL OF CHROMATOGRAPHY, 1989, 463 (01): : 165 - 170
  • [47] Poly(N-vinylformamide) -: A drag-reducing polymer for biomedical applications
    Marhefka, Joie N.
    Marascalco, Philip J.
    Chapman, Toby M.
    Russell, Alan J.
    Kameneva, Marina V.
    BIOMACROMOLECULES, 2006, 7 (05) : 1597 - 1603
  • [48] Size-exclusion chromatography of poly(ethylene 2,6-naphthalate)
    Mourey, T. H.
    Slater, L. A.
    Galipo, R. C.
    Janes, D. L.
    Moody, R. E.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1256 : 129 - 135
  • [49] OPTIMIZATION OF EFFICIENCY IN SIZE-EXCLUSION CHROMATOGRAPHY
    ENGELHARDT, H
    AHR, G
    JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC): : 385 - 397
  • [50] Sizing Up Size-Exclusion Chromatography
    Matheson, Alasdair
    Striegel, Andre
    LC GC EUROPE, 2019, 32 (08) : 420 - 423