Development of a portable diagnostic apparatus for coil insulators in low-voltage induction motors

被引:5
|
作者
Takezawa, Y [1 ]
Itoh, Y
Shimodera, M
Miya, H
机构
[1] Hitachi Ltd, Hitachi Res Lab, Ibaraki, Osaka, Japan
[2] Hitachi Bldg Syst Engn Co Ltd, Tokyo, Japan
关键词
D O I
10.1109/94.671964
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When most organic insulators are exposed to thermal stress, they turn darker in color. The increase of electronic transition absorption due to thermal oxidation of the resin is responsible for this darker coloration. A correlation between the degree of aging of these insulators and their reflective absorbances in the near IR (infrared) wavelength range has been established previously. In this paper, a novel non-destructive diagnostic apparatus using an optical fiber sensor developed to evaluate the aging of thermally deteriorated insulators is reported. The key point of this technique is measuring the change of reflective absorbance ratio at two different wavelengths. The sensor consists of two plastic optical fibers (for light transmitting and receiving), a plastic optical coupler, two kinds of near-IR light emitting diodes as light sources, and an optical power meter as a detector, and hence is very compact and lightweight (< 2 kg). The aging of an insulator can be estimated using the diagnostic curve, which is obtained by an accelerated heating experiment using model pieces. We applied this measurement technique to predict the residual life of low-voltage induction motors used in elevators.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 50 条
  • [41] High-performance Synchronous Reluctance Motors in Low-voltage Applications
    Staudt, Stefan
    Teigelkoetter, Johannes
    Kowalski, Thomas
    Stock, Alexander
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [42] Technique for evaluating the energy efficiency of modern low-voltage asynchronous motors
    Andrianov M.V.
    Rodionov R.V.
    Russ Electr Eng, 2008, 11 (604-607): : 604 - 607
  • [43] Insulation Life Span of Low-Voltage Electric Motors-A Survey
    Hopner, Vanessa Neves
    Wilhelm, Volmir Eugenio
    ENERGIES, 2021, 14 (06)
  • [44] TRADE-OFFS IN OVERLOAD PROTECTION FOR LOW-VOLTAGE MOTORS.
    Paape Sr., Kenneth L.
    Manthe, Michael
    IEEE Conference Record of Industrial and Commercial Power Systems Technical Conference, 1981, : 35 - 44
  • [45] Development of a Universally Applicable Condition Monitoring System for Predictive Maintenance and Efficiency Evaluation of Low-voltage Motors
    Reuter T.
    Schmidt J.
    Grundmann A.
    ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb, 2022, 117 (10): : 659 - 666
  • [47] VERY LOW-VOLTAGE OPERATION ICS FOR PORTABLE RADIO RECEIVER USE
    KUWAHARA, H
    KUSAKABE, H
    YOKOHAMA, S
    TANAKA, T
    YOSHIDA, Y
    AOKI, H
    TANAKA, C
    KUBO, M
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1986, 32 (01) : 44 - 52
  • [48] Plastic Portable Bags as Low-Voltage Rescue Aids in Households.
    Irresberger, G.
    Bulletin de l'Association Suisse des Electriciens, 1975, 66 (05): : 277 - 284
  • [49] SamicaShield® Insulation System for frequency-converter-driven low-voltage three-phase motors -: SamicaFirewall® Insulation System for low-voltage three-phase motors (smoke-dissipating motors)
    Brandes, H
    Partzsch, T
    Klotsche, H
    Speck, J
    ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 195 - 198
  • [50] Current Measurement Technology Based on Rogowski Coil Low Voltage Apparatus
    Lang Fu-cheng
    Zhang Hong-kui
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 5895 - 5898