Measurements of ocular properties in response to intraocular pressure changes using an ultrasonic system

被引:0
|
作者
He, Xiaoyin [1 ]
Liu, Jun [2 ]
机构
[1] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Biomed Engn, Dept Ophthalmol, Dept Vet Biosci, Columbus, OH 43210 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An ultrasonic system was developed to measure the biomechanical properties of intact corneas and determine the effects of an elevated intraocular pressure (IOP) on these properties. Accurate measurement of IOP is essential for early detection of blinding disease, glaucoma. Inter-subject variations of biomechanical properties may have introduced significant errors to IOP measurements using the current gold standard - Goldmann Applanation Tonometry. Therefore, it is important to develop a non-invasive method for measuring corneal biomechanical properties in vivo. In this study, an ultrasonic measurement technique in combination with a mathematical model for wave propagation in thin layers was developed to estimate corneal properties and to differentiate the changes of the corneal properties in response to IOP changes in five enucleated porcine eyes. The measurements were performed with the IOPs adjusted at three different levels. Results showed that the ultrasonic method was sensitive to corneal property changes associated with IOP changes. We concluded that the ultrasonic method has the potential to implement non-invasive measurements of corneal properties in vivo.
引用
收藏
页码:3026 / +
页数:2
相关论文
共 50 条
  • [31] Intraocular pressure changes after peribulbar injections with and without ocular compression
    Bowman, R
    Liu, C
    Sarkies, N
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (05) : 394 - 397
  • [32] The Clinical Interpretation of Changes in Intraocular Pressure Measurements Using Goldmann Applanation Tonometry: A Review
    Pearce, John G.
    Maddess, Ted
    JOURNAL OF GLAUCOMA, 2019, 28 (04) : 302 - 306
  • [33] How accommodative changes can affect intraocular pressure and ocular biometrics
    Toris, Carol
    Raghupathy, Sangeetha
    Tye, George
    Baig, Alia
    Stokkermans, Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [34] The impact of ocular hemodynamics and intracranial pressure on intraocular pressure during acute gravitational changes
    Nelson, Emily S.
    Mulugeta, Lealem
    Feola, Andrew
    Raykin, Julia
    Myers, Jerry G.
    Samuels, Brian C.
    Ethier, C. Ross
    JOURNAL OF APPLIED PHYSIOLOGY, 2017, 123 (02) : 352 - 363
  • [35] A Compact Optical Pressure Measurement System for Acquiring Intraocular Pressure and Ocular Pulse
    Phan, Alex
    Joslin, Kevin
    Truong, Phuong
    Camp, Andrew
    Talke, Frank E.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4212 - 4216
  • [36] Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature
    Franco, Sandra
    Lira, Madalena
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (06) : 469 - 475
  • [37] Intraocular pressure and biomechanical corneal properties measure by ocular response analyser in patients with primary congenital glaucoma
    Perucho-Gonzalez, Lucia
    Martinez de la Casa, Jose Maria
    Morales-Fernandez, Laura
    Baneros-Rojas, Paula
    Saenz-Frances, Federico
    Garcia-Feijoo, Julian
    ACTA OPHTHALMOLOGICA, 2016, 94 (05) : e293 - e297
  • [38] Properties associated with intraocular pressure dissonance as measured by Goldman Applanation Tonometry compared to the Ocular Response Analyzer
    Johnson, Matthew C.
    Kang, Joyce
    Zhao, Yan
    Lin, Michael M.
    Friedman, David S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [39] Potential effects of systematic errors in intraocular pressure measurements on screening for ocular hypertension
    Turner, M. J.
    Graham, S. L.
    Avolio, A. P.
    Mitchell, P.
    EYE, 2013, 27 (04) : 502 - 506
  • [40] Evaluation of Intraocular Pressure by Ocular Response Analyzer in Patients Undergoing Hemodialysis
    Yuksel, Nilay
    Duru, Necati
    Uz, Ebru
    Mutlu, Melek
    Altinkaynak, Hasan
    Ozen, Umut
    Turkyilmaz, Mustafa
    Cagil, Nurullah
    JOURNAL OF GLAUCOMA, 2016, 25 (04) : E355 - E358