Validation of Geant4 atomic relaxation against the NIST physical reference data

被引:27
|
作者
Guatelli, S. [1 ]
Mantero, A. [1 ]
Mascialino, B. [1 ]
Pia, M. G. [1 ]
Zampichelli, V. [1 ]
机构
[1] Ist Nazl Fis Nucl, Sezione Genova, I-16146 Genoa, Italy
关键词
Auger electron; fluorescence; Geant4; Monte Carlo; simulation;
D O I
10.1109/TNS.2007.894814
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The accuracy of the Geant4 component for the simulation of atomic relaxation has been evaluated against the experimental measurements of the NIST Standard Reference Data. The validation study concerns X-ray and Auger transition energies. The comparison of the simulated and experimental data with rigorous statistical methods demonstrates the excellent accuracy of the simulation of atomic de-excitation in Geant4.
引用
收藏
页码:594 / 603
页数:10
相关论文
共 50 条
  • [1] Validation of Geant4 Atomic Relaxation against the NIST reference data
    Guatelli, S.
    Mantero, A.
    Mascialino, B.
    Pia, M. G.
    Zampichelli, V.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1516 - 1518
  • [2] Comparison of Geant4 electromagnetic physics models against the NIST reference data
    Amako, K
    Guatelli, S
    Ivanchenko, VN
    Maire, M
    Mascialino, B
    Murakami, K
    Nieminen, P
    Pandola, L
    Parlati, S
    Pia, MG
    Piergentili, M
    Sasaki, T
    Urban, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 910 - 918
  • [3] Geant4 atomic relaxation
    Guatelli, Susanna
    Mantero, Alfonso
    Mascialino, Barbara
    Nieminen, Petteri
    Pia, Maria Grazia
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (03) : 585 - 593
  • [4] Geant4 atomic relaxation
    Guatelli, S
    Mantero, A
    Mascialino, B
    Nieminen, P
    Pia, MG
    Saliceti, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2178 - 2181
  • [5] GEANT4 atomic relaxation data for transfermium nuclei (Z=101-104)
    Chakma, R.
    Fritzsche, S.
    Hauschild, K.
    Lopez-Martens, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [6] GEANT4 and its validation
    Amako, K
    Guatelli, S
    Ivanchencko, V
    Maire, M
    Mascialino, B
    Murakami, K
    Pandola, L
    Parlati, S
    Pia, MG
    Piergentili, M
    Sasaki, T
    Urban, L
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 44 - 49
  • [7] Validation of Geant4 electromagnetic physics versus protocol data
    Amako, K
    Guatelli, S
    Ivanchencko, V
    Maire, M
    Mascialino, B
    Murakami, K
    Pandola, L
    Parlati, S
    Pia, MG
    Piergentili, M
    Sasaki, T
    Urban, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2115 - 2119
  • [8] Validation of Geant4 hadronic physics
    Beringer, J
    Folger, G
    Gianotti, F
    Ribon, A
    Wellisch, JP
    Barberis, D
    Cervetto, M
    Osculati, B
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 494 - 498
  • [9] Validation of hadronic models in Geant4
    Koi, Tatsumi
    Wright, Dennis H.
    Folger, Gunter
    Ivantchenko, Vladimir
    Kossov, Mikhail
    Starkov, Nikolai
    Heikkinen, Aatos
    Truscott, Pete
    Lei, Fan
    Wellisch, Hans-Peter
    HADRONIC SHOWER SIMULATION WORKSHOP, 2007, 896 : 21 - +
  • [10] The Geant4 physics validation repository
    Wenzel, H.
    Yarba, J.
    Dotti, A.
    21ST INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP2015), PARTS 1-9, 2015, 664