Study of Liquid Weeping at a Tapered Orifice in a Bubble Column Reactor by a Computer-Aided Image Analysis Algorithm

被引:4
|
作者
Hossain, Md Iqbal [1 ]
Pang, Si Qi [1 ]
Pang, Qing Xi [1 ]
Yang, Yanhui [1 ]
Lau, Raymond [1 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 637459, Singapore
关键词
SUBMERGED ORIFICE; MODEL; FLOW;
D O I
10.1021/ie901516f
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Understanding the phenomenon of liquid weeping requires knowledge of the bubbling and weeping cycle. Hence, an image analysis algorithm is developed and subsequently coupled with high-speed imaging techniques to examine the different stages in the bubbling and weeping cycle automatically. The bubbling and weeping cycle is studied under various operating conditions, using the developed algorithm, coupled with high-speed imaging techniques and the pressure fluctuation measurement. The effect of orifice angle (where the orifice angle is a measure of the orifice taperness) on the liquid weeping rate is evaluated over a range of superficial orifice gas velocities and justified with the aid of the developed algorithm, coupled with high-speed imaging techniques. A gas distributor plate with negative angle orifices is recommended for improved operation of industrial bubble column reactors over the range of superficial orifice gas velocities considered in this study, because it substantially decreases the liquid weeping rate.
引用
收藏
页码:3840 / 3848
页数:9
相关论文
共 50 条
  • [41] COMPUTER-ASSISTANCE IN NEUROIMAGING: FROM QUANTITATIVE IMAGE ANALYSIS TO COMPUTER-AIDED DIAGNOSISle
    Hahn, Horst Karl
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 275 - 275
  • [42] Journey toward computer-aided diagnosis role of image texture analysis
    Tourassi, GD
    RADIOLOGY, 1999, 213 (02) : 317 - 320
  • [43] A study on the effect of morphological filters on computer-aided medical image diagnosis
    Homma N.
    Kawai Y.
    Shimoyama S.
    Ishibashi T.
    Yoshizawa M.
    Artificial Life and Robotics, 2009, 14 (02) : 191 - 194
  • [44] COMPUTER-AIDED ALGORITHM BASED ON THE YASUURA METHOD FOR ANALYSIS OF DIFFRACTION BY A GRATING
    MATSUDA, T
    OKUNO, Y
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (09): : 1693 - 1700
  • [45] A STUDY OF SKIN FLAP SUSCEPTIBILITY TO VASCULAR OCCLUSION UTILIZING COMPUTER-AIDED IMAGE-ANALYSIS
    SMITH, P
    HANSEN, R
    CLINICAL RESEARCH, 1993, 41 (03): : A710 - A710
  • [46] RETRACTION: Computer-aided visual communication design based on image detail enhancement algorithm
    Jiang, Jian
    OPTICAL AND QUANTUM ELECTRONICS, 2024, 56 (10)
  • [47] Computer-Aided Image Analysis Algorithm to Enhance In Vivo Diagnosis of Plaque Erosion by Intravascular Optical Coherence Tomography
    Wang, Zhao
    Jia, Haibo
    Tian, Jinwei
    Soeda, Tsunenari
    Vergallo, Rocco
    Minami, Yoshiyasu
    Lee, Hang
    Aguirre, Aaron
    Fujimoto, James G.
    Jang, Ik-Kyung
    CIRCULATION-CARDIOVASCULAR IMAGING, 2014, 7 (05) : 805 - 810
  • [48] Computer-aided Digital Image Inpainting Algorithm and Image Special Effects Processing Based on Deep Learning
    Li, Zhiguang
    Jahng, Surng Gahb
    Computer-Aided Design and Applications, 2024, 21 (S1): : 88 - 100
  • [49] MANUAL AND COMPUTER-AIDED SPACE ANALYSIS - A COMPARATIVE-STUDY
    SCHIRMER, UR
    YEN, CH
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 518 - 518
  • [50] Computer-Aided Modelling and Analysis of PV Systems: A Comparative Study
    Koukouvaos, Charalambos
    Kandris, Dionisis
    Samarakou, Maria
    SCIENTIFIC WORLD JOURNAL, 2014,