Effect of Applying Positive Pressure With or Without Endotracheal Suctioning During Extubation: A Laboratory Study

被引:13
|
作者
Andreu, Mauro F. [1 ]
Salvati, Iris G. [1 ]
Donnianni, Mariana C. [1 ]
Ibanez, Belen [1 ]
Cotignola, Mariana [1 ]
Bezzi, Marco [1 ]
机构
[1] Hosp Santojanni, Intens Care Unit, Diagnost & Treatment Dept, Buenos Aires, DF, Argentina
关键词
airway extubation; endotracheal suctioning; extubation methods; positive pressure ventilation; aspiration; fluids leakage; positive end expiratory pressure; END-EXPIRATORY PRESSURE; INTENSIVE-CARE UNITS; TRACHEAL EXTUBATION;
D O I
10.4187/respcare.03121
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: During invasive mechanical ventilation, secretions accumulate in the subglottic space; consequently, there is a risk of aspiration of these secretions into the airway during cuff deflation and extubation. To minimize this risk, 2 extubation methods are used. The first consists of introducing a suction catheter into the endotracheal tube (ETT) and the trachea. After initiating suctioning, the cuff is deflated and the ETT is removed together with the suction catheter. The second technique involves applying positive pressure to the ETT using a resuscitation bag. Once the manual breath is delivered, the ETT cuff is deflated and the ETT is removed without suction. The aim of this laboratory study is to determine the existence and magnitude of differences in leak volume during cuff deflation and extubalion using various combinations of positive pressure with or without endotracheal suctioning. METHODS: An ETT connected to a ventilator was placed in a model trachea. Colored water was instilled in the space above the cuff. To measure the leak volume, a collection chamber was attached to the distal end of the model. Nine procedures were defined, based on the delivery of different positive pressure levels with or without endotracheal suctioning during extubation. The volume of leakage, in milliliters, was the unit of analysis. Procedures yielding values lower than 1 mL were assessed by the Friedman test, and a P value of less than .05 was considered significant. Post hoc comparisons were performed with a Wilcoxon test, followed by a Bonferroni correction. RESULTS: The application of CPAP(15), pressure support ventilation (PSV)(15/10), and PSV20/5 produced 0.4, 0.2, and 0.1 mL of leak volume, respectively. Statistically significant differences were found between CPAP(15) and PSV15/10 (P = .003) and between CPAP(15) and PSV20/5 (P = .01), but not between PSV15/10 and PSV20/5 (P = .30). The addition of suctioning increased leak volume, with statistically significant differences between CPAP(15) and CPAP(15) + endotracheal suctioning (P = .001) and between PSV15/10 and PSV15/10 + endotracheal suctioning (P = .001). CONCLUSIONS: Endotracheal suctioning during cuff deflation and extubation produced greater leakage. Application of CPAP(15), PSV15/10, and PSV20/5 resulted in the lowest leak values, with the best results being obtained with the use of PSV15/10 and PSV20/5. (C) 2014 Daedalus Enterprises
引用
收藏
页码:1905 / 1911
页数:7
相关论文
共 50 条
  • [31] AVOIDING CIRCULATORY COMPLICATIONS DURING ENDOTRACHEAL INTUBATION AND INITIATION OF POSITIVE PRESSURE VENTILATION
    Manthous, Constantine A.
    JOURNAL OF EMERGENCY MEDICINE, 2010, 38 (05): : 622 - 631
  • [32] The effect on intraocular pressure of endotracheal intubation or laryngeal mask use during TIVA without the use of muscle relaxants
    Kiliçkan, L
    Baykara, N
    Gürkan, Y
    Toker, K
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1999, 43 (03) : 343 - 346
  • [33] Safe and effective pressure of endotracheal tube suctioning based on sputum viscosity grades during artificial airway open suctioning procedures: A double-blind randomized controlled trial
    Liu, Weiquan
    Gu, Chunling
    Li, Miqi
    Xiong, Jie
    NURSING IN CRITICAL CARE, 2024,
  • [34] The effect of sedation and/or analgesia as rescue treatment during noninvasive positive pressure ventilation in the patients with Interface intolerance after Extubation
    Ni, Yue-Nan
    Wang, Ting
    Yu, He
    Liang, Bin-Miao
    Liang, Zong-An
    BMC PULMONARY MEDICINE, 2017, 17
  • [35] The effect of sedation and/or analgesia as rescue treatment during noninvasive positive pressure ventilation in the patients with Interface intolerance after Extubation
    Yue-Nan Ni
    Ting Wang
    He Yu
    Bin-Miao Liang
    Zong-An Liang
    BMC Pulmonary Medicine, 17
  • [36] Comparative study of the effect of two different doses of intravenous labetalol on the cardiovascular response to endotracheal extubation
    Shetabi, Hamidreza
    Nazemroaya, Behzad
    Mahjobipoor, Hosein
    Majidi, Sanaz
    JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2023, 15 (02) : 98 - 105
  • [37] ENDOTRACHEAL-TUBE VERSUS FACE MASK WITH AND WITHOUT CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP)
    JOUSELA, I
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1993, 37 (04) : 381 - 385
  • [38] A Pilot Study of Responses to Suctioning Among Neonates on Bubble Nasal Continuous Positive Airway Pressure
    Sweet, Michele
    Armbruster, Debra
    Bainbridge, Erin
    Reiner, Brianna
    Tan, Alai
    Chipps, Esther
    ADVANCES IN NEONATAL CARE, 2017, 17 (06) : E3 - E11
  • [39] Roles of endotracheal tubes and slip joints in respiratory pressure loss: a laboratory study
    Yoshihiro Takasugi
    Koichi Futagawa
    Kouhei Kazuhara
    Satoshi Morishita
    Takahiko Okuda
    Journal of Anesthesia, 2016, 30 : 789 - 795
  • [40] Roles of endotracheal tubes and slip joints in respiratory pressure loss: a laboratory study
    Takasugi, Yoshihiro
    Futagawa, Koichi
    Kazuhara, Kouhei
    Morishita, Satoshi
    Okuda, Takahiko
    JOURNAL OF ANESTHESIA, 2016, 30 (05) : 789 - 795