Quantitative two-dimensional HSQC experiment for high magnetic field NMR spectrometers

被引:48
|
作者
Koskela, Harri [1 ]
Heikkila, Outi [2 ]
Kilpelainen, Ilkka [3 ]
Heikkinen, Sami [3 ]
机构
[1] Univ Helsinki, VERIFIN, FIN-00014 Helsinki, Finland
[2] Univ Helsinki, Folkhalsan Inst Genet, Folkhalsan Res Ctr, FIN-00014 Helsinki, Finland
[3] Univ Helsinki, Organ Chem Lab, FIN-00014 Helsinki, Finland
关键词
Quantitative two-dimensional NMR; (13)C offset compensation; Carr-Purcell-Meiboom-Gill sequence; Adiabatic inversion pulses; PM-BEBOP; Q-OCCAHSQC; Human blood plasma; BROAD-BAND INVERSION; MULTIPLICITY-EDITED HSQC; HUMAN BLOOD-PLASMA; ADIABATIC PULSES; H-1-NMR SPECTROSCOPY; COMPOSITE PULSES; POLARIZATION TRANSFER; POPULATION-INVERSION; REFOCUSING PULSES; SINGLE-SCAN;
D O I
10.1016/j.jmr.2009.09.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The finite RF power available on carbon channel in proton-carbon correlation experiments leads to non-uniform cross peak intensity response across carbon chemical shift range. Several classes of broadband pulses are available that alleviate this problem. Adiabatic pulses provide an excellent magnetization inversion over a large bandwidth, and very recently, novel phase-modulated pulses have been proposed that perform 900 and 1800 magnetization rotations with good offset tolerance. Here, we present a study how these broadband Pulses (adiabatic and phase-modulated) can improve quantitative application of the heteromolecular single quantum coherence (HSQC) experiment on high magnetic field strength NMR spectrometers. Theoretical and experimental examinations of the quantitative, offset-compensated. CPMG-adjusted HSQC (Q-OCCAHSQC) experiment are presented. The proposed experiment offers a formidable improvement to the offset performance; (13)C offset-dependent standard deviation of the peak intensity was below 6% in range of +/- 20 kHz. This covers the carbon chemical shift range of 150 ppm, which contains the protonated carbons excluding the aldehydes, for 22.3 T NMR magnets. A demonstration of the quantitative analysis of a fasting blood plasma sample obtained from a healthy volunteer is given. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 33
页数:10
相关论文
共 50 条
  • [31] Magnetoresistance of two-dimensional fermions in a random magnetic field
    Khveshchenko, DV
    PHYSICAL REVIEW LETTERS, 1996, 77 (09) : 1817 - 1820
  • [32] A TWO-DIMENSIONAL POLARONIC DONOR IN A MAGNETIC-FIELD
    ERCELEBI, A
    SAQQA, B
    JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1988, 21 (09): : 1769 - 1777
  • [33] Internetwork magnetic field as revealed by two-dimensional inversions
    Danilovic, S.
    van Noort, M.
    Rempel, M.
    ASTRONOMY & ASTROPHYSICS, 2016, 593
  • [34] Properties of a two-dimensional semimetal in a strong magnetic field
    Batyev, E. G.
    JOURNAL OF EXPERIMENTAL AND THEORETICAL PHYSICS, 2010, 110 (01) : 88 - 97
  • [35] Quantum lifetime of two-dimensional electrons in a magnetic field
    Dietrich, Scott
    Vitkalov, Sergey
    Dmitriev, D. V.
    Bykov, A. A.
    PHYSICAL REVIEW B, 2012, 85 (11)
  • [36] Properties of a two-dimensional semimetal in a strong magnetic field
    É. G. Batyev
    Journal of Experimental and Theoretical Physics, 2010, 110 : 88 - 97
  • [37] Confined Two-Dimensional Hydrogen Atom in Magnetic Field
    Kumar, Kirtee
    Talwar, Shalini Lumb
    Lumb, Sonia
    Prasad, Vinod
    3RD INTERNATIONAL CONFERENCE ON CONDENSED MATTER & APPLIED PHYSICS (ICC-2019), 2020, 2220
  • [38] Two-dimensional electron liquid in a weak magnetic field
    Glazman, LI
    Aleiner, IL
    SURFACE SCIENCE, 1996, 361 (1-3) : 485 - 488
  • [39] Two-dimensional quantum dot in an external magnetic field
    Lipovka, A
    Marin, JL
    Riera, R
    Rosas, R
    PHYSICS OF LOW-DIMENSIONAL STRUCTURES, 2002, 9-10 : 97 - 104