Low-Frequency Magnetic Field Exposure System for Cells Electromagnetic Biocompatibility Studies

被引:2
|
作者
Judakova, Zuzana [1 ]
Janousek, Ladislav [1 ]
Radil, Roman [1 ]
Carnecka, Lucia [1 ]
机构
[1] Univ Zilina, Fac Elect Engn & Informat Technol, Dept Electromagnet & Biomed Engn, Zilina 01026, Slovakia
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 14期
关键词
low-frequency electromagnetic field; biocompatibility; applicator system; coil; ion parametric resonance theory; YPD medium; ELF-MF; MT; HZ;
D O I
10.3390/app12146846
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The advancement in science and technology has resulted in the invention and widespread usage of many electrical devices in the daily lives of humans. The exponential use of modern electronic facilities has increased electromagnetic field exposure in the current population. Therefore, the presented article deals with designing, constructing, and testing a new applicator system developed for cells electromagnetic biocompatibility studies. The applicator system is intended for studying the non-thermal impacts of low-frequency magnetic field on cell cultures growth. Main attention is focused on increasing the capacity of the applicator and effectivity of the experiments. The key idea is to reach high level of the magnetic field homogeneity in an area of interest and the temperature stability during the biocompatibility studies. The applicator system is designed based on numerical simulations and its construction, measurements, and properties evaluation are also reported for proving the applicator's functionality. The new applicator allows performing five parallel experiments at the same time under the same conditions. The simulation together with the experimental results confirm that the magnetic field homogeneity reaches 99% in the area of interest and the maximum temperature instability is lower than 2% during the experiments. The effectiveness of new applicator is tested and proved during preliminary experiments with Saccharomyces Cerevisiae cells. The observed effects of MF exposure represent maximal stimulation of 74% and maximal inhibition of 49%. The reason why MF with the same parameters induces inhibition in one sample and stimulation in the other will be the subject of further research.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] LOW-FREQUENCY OSCILLATIONS OF A PLASMA IN A MAGNETIC FIELD
    STEPANOV, KN
    SOVIET PHYSICS JETP-USSR, 1959, 8 (05): : 808 - 811
  • [32] The effects of exposure to extremely low-frequency magnetic field and amphetamine on the reduced glutathione in the brain
    Jelenkovic, A
    Janac, B
    Pesic, V
    Jovanovic, MD
    Vasiljevic, I
    Prolic, Z
    BIOPHYSICS FROM MOLECULES TO BRAIN: IN MEMORY OF RADOSLAV K. ANDJUS, 2005, 1048 : 377 - 380
  • [33] An analysis of differences in the low-frequency electric and magnetic field exposure standards of ICES and ICNIRP
    Reilly, JP
    HEALTH PHYSICS, 2005, 89 (01): : 71 - 80
  • [34] Conductometry as an evaluation tool in research into the impact of low-frequency electromagnetic field irradiation on cells
    Judakova, Zuzana
    Janousek, Ladislav
    Carnecka, Lucia
    Svantnerova, Ivana
    2022 23RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL PROBLEMS OF ELECTRICAL ENGINEERING (CPEE), 2022,
  • [35] Growth modification of human colon adenocarcinoma cells exposed to a low-frequency electromagnetic field
    Gómez, MJR
    Vega, JMP
    de la Peña, L
    Carmona, LG
    Morillo, MM
    JOURNAL OF PHYSIOLOGY AND BIOCHEMISTRY, 1999, 55 (02) : 79 - 83
  • [36] Calcium homeostasis and low-frequency magnetic and electric field exposure: A systematic review and meta-analysis of in vitro studies
    Golbach, Lieke A.
    Portelli, Lucas A.
    Savelkoul, Huub F. J.
    Terwel, Sofie R.
    Kuster, Niels
    de Vries, Rob B. M.
    Verburg-van Kemenade, B. M. Lidy
    ENVIRONMENT INTERNATIONAL, 2016, 92-93 : 695 - 706
  • [37] Exposure of Aortic Vascular Smooth Muscle Cells to Low-Frequency Electromagnetic Field Inhibits Osteopontin Expression and Matrix Metalloproteinase Activity
    Hu, Tao
    Li, Huan
    Zhang, Xiaojun
    Luan, Ronghua
    Li, Chengxiang
    Cheng, Hexiang
    Wang, Haichang
    Li, Xiaoyang
    Zeng, Yanjun
    INTERNATIONAL HEART JOURNAL, 2008, 49 (05) : 597 - 604
  • [38] Research on Automotive Low-Frequency Electromagnetic Calibration System
    Huang, Heqing
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND INTELLIGENT MANUFACTURING (ITIM 2017), 2017, 142 : 81 - 84
  • [39] Evaluating alternative exposure indices in epidemiologic studies on extremely low-frequency magnetic fields
    Juutilainen, J
    Hatfield, T
    Laara, E
    BIOELECTROMAGNETICS, 1996, 17 (02) : 138 - 143
  • [40] Fluxgate magnetometer for low-frequency magnetic electromagnetic compatibility measurements
    Weyand, K
    Bosse, V
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (02) : 617 - 620