EVALUATION OF ANNUAL PERFORMANCE OF MULTI-TYPE AIR-CONDITIONERS FOR BUILDINGS (COMPARISON OF EHP AND GHP)

被引:0
|
作者
Watanabe, Choyu [1 ]
Hirota, Masafumi
Ohashp, Ei-ichiro
Nagamatsu, Katsuaki [1 ]
Nakayama, Hiroshi [1 ]
机构
[1] Chubu Elect Power Co Inc, Energy Applicat R&D Ctr, Midori Ku, Nagoya, Aichi 4598522, Japan
关键词
Heat Pump; Coefficient of Performance; Partial Load Performance; Annual Energy Consumption;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, the results are presented on the partial thermal load performance tests of multi-type air-conditioners for buildings. We tested two types of air-conditioners, heat pump driven by electric motors (EHP) and that driven by gas engines (GHP), with a rated cooling capacity of 56 kW. The coefficient of performance (COP) and the annual energy consumption measured by those tests were closely compared with those predicted by JIS. In EHP, the measured COP attains the maximum under the indoor thermal load ratio of 50 %, while COP in GHP decreases gradually as the thermal load ratio is decreased. Based on these results, we examined the accuracies of COP and the annual energy consumption predicted by JIS. We found that in both EHP and GHP the current calculating method prescribed in JIS could not reproduce the deteriorations of COP that appeared under the low thermal load conditions. As a result, the annual energy consumption is seriously underestimated by JIS.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 29 条
  • [21] CAPACITY SELF-CONTROLLABLE ROTARY TYPE COMPRESSORS FOR AUTOMOTIVE AIR-CONDITIONERS (2ND REPORT, DESIGN THEORY OF MULTI-VANE TYPE).
    Maruyama, Teruo
    Yamauchi, Shinya
    Kagoroku, Nobuo
    Abe, Yoshikazu
    Bulletin of the JSME, 1986, 29 (258): : 4209 - 4217
  • [22] Performance Evaluation of Multi-type Five-axis Machine Tool With Recognizable Performance Evaluation by Fuzzy Theory
    Chang, Han-Jui
    2019 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM-QINGDAO), 2019,
  • [23] A comparison of classifier performance for fault diagnosis of induction motor using multi-type signals
    Niu, Gang
    Son, Jong-Duk
    Widodo, Achmad
    Yang, Bo-Suk
    Hwang, Don-Ha
    Kang, Dong-Sik
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2007, 6 (03): : 215 - 229
  • [24] Experimental verification of artificial neural network scalability for performance monitoring of multi-split type air conditioners
    Sholahudin
    Giannetti, Niccolo
    Miyaoka, Yoichi
    Saito, Kiyoshi
    Tanaka, Katsuhiko
    Ogami, Hiroto
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [25] Energetic, economic and environmental analyses of frost-free air-source heat pump in multi-type buildings and different locations
    Huang, Shifang
    Wang, Libo
    Xie, Lingyun
    Liu, Jian
    Zhang, Xiaosong
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [26] A New Method of Information Aggregation for Multi-type Evaluation Subjects-Involving Teachers' Performance Evaluation Based on TOW Operator
    Zhang, Faming
    APPLIED MATHEMATICS & INFORMATION SCIENCES, 2012, 6 (03): : 901 - 906
  • [27] Energy performance comparison of heating and air-conditioning systems for multi-family residential buildings
    Wang, Weimin
    Zhang, Jian
    Jiang, Wei
    Liu, Bing
    HVAC&R RESEARCH, 2011, 17 (03): : 309 - 322
  • [28] Study on simplified evaluation method for annual operation performance of multi-connected air conditioning system
    Zhang, Dongliang
    Xia, Xueying
    Zhang, Xu
    APPLIED THERMAL ENGINEERING, 2016, 99 : 1165 - 1170
  • [29] Multi-connected Air-Conditioning System Standards Analysis and Annual Operating Performance Evaluation
    Zhang, Dong-liang
    Zhang, Xu
    Cai, Ning
    LOW-CARBON CITY AND NEW-TYPE URBANIZATION, 2015, : 55 - 63