Characterization of the surface redox process of adsorbed cercosporin (CER) at glassy carbon electrodes by anodic stripping square-wave voltammetry

被引:10
|
作者
Marchiando, NC [1 ]
Zón, MA [1 ]
Fernández, H [1 ]
机构
[1] Univ Nacl Rio Cuarto, Dept Quim & Fis, RA-5800 Rio Cuarto, Argentina
关键词
cercosporin (CER); stripping voltammetry; adsorptive accumulation; square-wave voltammetry; thermodynamic parameters; kinetics parameters;
D O I
10.1002/elan.200390003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The adsorptive accumulation of cercosporin (CER) at glassy carbon electrodes is studied by square-wave voltammetry (SWV). The Freundlich adsorption isotherm resulted in being the best one to describe the specific interaction of CER with glassy carbon electrodes by using a fitting procedure of experimental fractional surface coverage vs. the CER bulk concentration (c*(CER)). SWV was also used to generate Q vs. c*(CER) and I-p,I-n. vs. c*(CER) calibration plots from pure commercial reagent solutions. Theoretical detection limits of 1.8 x 10(-7) and 9.7 x 10(-8) M were calculated from Q. vs. c*(CER) and I-p,I-n vs. c*(CER) plots, respectively. The lowest concentration value measured experimentally from calibration plots performed at a f = 40 Hz for a signal to noise ratio of 2:1 was 3.7 x 10(-8) M, being this value two orders of magnitude smaller than that obtained previously by us from the diffusion controlled CER reduction peak. I-p,I-n./f vs. f plots from SW voltammograms performed at different c*(CER) as well as different accumulation times showed the so-called "quasi-reversible maxima". A splitting of the voltammetric peak was also observed by increasing the SW amplitude at a given frequency. A value of ( - 0.260 +/- 0.011) V was determined for the formal potential of the adsorbed redox couple from the split voltammetric peak. A full characterization of the surface redox process was obtained by applying the methods of the "quasi-reversible maximum" and the "split SW peak". In 1 M HClO4 aqueous solution, the formal rate constant and the anodic transfer coefficient were (3.5 +/- 0.5) x 10(2) s(-1) and (0.50 +/- 0.03), respectively. Besides, the number of electrons exchanged during the redox reaction was calculated as n approximate to 1.
引用
收藏
页码:40 / 48
页数:9
相关论文
共 50 条
  • [31] The electrochemical reaction mechanism of arsenic on gold analyzed by anodic stripping Square-wave voltammetry
    Robles, Alicia D.
    Vettorelo, Sabrina N.
    Gerpe, Marcela
    Garay, Fernando
    ELECTROCHIMICA ACTA, 2017, 227 : 447 - 454
  • [32] Determination of Allura Red in the Presence of Cetylpyridinium Bromide by Square-wave Adsorptive Stripping Voltammetry on a Glassy Carbon Electrode
    Edgar Nagles
    Olimpo García-Beltrán
    Analytical Sciences, 2018, 34 : 1171 - 1175
  • [33] Determination of cercosporin (CER) phytotoxin isolated from infected peanut leaves by using adsorptive stripping square wave voltammetry
    Marchiando, NC
    Zón, MA
    Fernández, H
    ANALYTICA CHIMICA ACTA, 2005, 550 (1-2) : 199 - 203
  • [34] A STUDY OF RIBOFLAVIN DETERMINATION BY SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY FILM ELECTRODES
    ECONOMOU, A
    FIELDEN, PR
    ELECTROANALYSIS, 1995, 7 (05) : 447 - 453
  • [35] Trace determination of chromium by square-wave adsorptive stripping voltammetry on bismuth film electrodes
    Chatzitheodorou, E
    Economou, A
    Voulgaropoulos, A
    ELECTROANALYSIS, 2004, 16 (21) : 1745 - 1754
  • [36] A study of in situ plated tin-film electrodes for the determination of trace metals by means of square-wave anodic stripping voltammetry
    Czop, Edyta
    Economou, Anastasios
    Bobrowski, Andrzej
    ELECTROCHIMICA ACTA, 2011, 56 (05) : 2206 - 2212
  • [37] DETERMINATION OF TRACES OF CADMIUM IN ZINC AND ITS COMPOUNDS BY SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY
    TSUCHIAI, H
    ODASHIMA, T
    ISHII, H
    BUNSEKI KAGAKU, 1986, 35 (04) : 394 - 399
  • [38] SQUARE-WAVE VOLTAMMETRY OF QUASI-REVERSIBLE SURFACE REDOX REACTIONS
    KOMORSKYLOVRIC, S
    LOVRIC, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 384 (1-2): : 115 - 122
  • [39] Determination of Caffeine Using a Simple Graphite Pencil Electrode with Square-Wave Anodic Stripping Voltammetry
    Suw Young Ly
    Young Sam Jung
    Myung Hoon Kim
    In kwon Han
    Woon Won Jung
    Hyun Sook Kim
    Microchimica Acta, 2004, 146 : 207 - 213
  • [40] SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY IN STATIONARY AND FLOWING SOLUTION - A COMPARATIVE-STUDY
    BRETT, CMA
    LIMA, JLFC
    GARCIA, MBQ
    ANALYST, 1994, 119 (06) : 1229 - 1233