Evaluation of the Dose Delivery Accuracy and Its Dependence On Imaging Modality and Deformable Image Registration Algorithm in Prostate Cancer Patients

被引:0
|
作者
Hammers, J.
Pirozzi, S. [1 ]
Lindsay, D. [2 ]
Kaidar-Person, O. [3 ]
Papanikolaou, N. [4 ]
Stathakis, S. [5 ]
Chen, R. [6 ]
Das, S. [2 ]
Mavroidis, P. [2 ]
机构
[1] MIM Software Inc, Cleveland, OH USA
[2] Univ N Carolina, Chapel Hill, NC 27515 USA
[3] Rambam Hlth Care Campus, Haifa, Israel
[4] Ut Hlth San Antonio, San Antonio, TX USA
[5] Univ Texas Hlth, San Antonio, TX USA
[6] UNC Hlth Care, Chapel Hill, NC USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MO-C930-Ge
引用
下载
收藏
页码:E402 / E402
页数:1
相关论文
共 50 条
  • [1] Evaluation of the Dose Delivery Consistency and Its Dependence on Imaging Modality and Deformable Image Registration Algorithm in Prostate Cancer Patients
    Hammers, Jacob
    Pirozzi, Sara
    Narayanasamy, Ganesh
    Lindsay, Daniel
    Kaidar-Person, Orit
    Tan, Xianming
    Chen, Ronald C.
    Das, Shiva K.
    Mavroidis, Panayiotis
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (01) : 74 - 86
  • [2] Evaluation of the Dose Delivery Consistency and Its Dependence on Imaging Modality and Deformable Image Registration Algorithm in Prostate Cancer Patients
    Jacob Hammers
    Sara Pirozzi
    Ganesh Narayanasamy
    Daniel Lindsay
    Orit Kaidar-Person
    Xianming Tan
    Ronald C. Chen
    Shiva K. Das
    Panayiotis Mavroidis
    Journal of Medical and Biological Engineering, 2022, 42 : 74 - 86
  • [3] Evaluation of Deformable Image Registration and Dose Accumulation in Prostate SBRT Patients
    Swamidas, J.
    Phurailatpam, R.
    Panda, S.
    Murthy, V.
    Joshi, K.
    Deshpande, D.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1150 - S1150
  • [4] Evaluation of deformable image registration algorithm for determination of accumulated dose for brachytherapy of cervical cancer patients
    Mohammadi, Reza
    Mahdavi, Seied Rabi
    Jaberi, Ramin
    Siavashpour, Zahra
    Janani, Leila
    Meigooni, Ali Soleimani
    Reiazi, Reza
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (05) : 469 - 478
  • [5] Evaluation of a Correction Algorithm for Improving the Accuracy of a Deformable Image Registration Algorithm
    Mallya, Y.
    Bzdusek, K.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [6] Estimation of Delivered Dose in Prostate Cancer Radiotherapy Based On Daily IGRT: Comparison with Planned Dose and Dependence On Deformable Image Registration Algorithm
    Hammers, J.
    Lindsay, D.
    Tan, X.
    Pirozzi, S.
    Stathakis, S.
    Papanikolaou, N.
    Wang, A.
    Chen, R.
    Das, S.
    Mavroidis, P.
    MEDICAL PHYSICS, 2019, 46 (06) : E330 - E330
  • [7] Evaluation of the Accuracy of Deformable Image Registration of Individual Structures Between CT and CBCT in Prostate Cancer Radiotherapy
    Hammers, J.
    Pirozzi, S.
    Matney, J.
    Kaidar-Person, O.
    Chen, R.
    Wang, A.
    Das, S.
    Mavroidis, P.
    MEDICAL PHYSICS, 2017, 44 (06) : 3219 - 3219
  • [8] Improving Dose Accuracy in Cancer Radiation Therapy Using Deformable Image Registration
    Amy Liu
    Yadin David
    Fred Hosea
    Richard Wu
    中国医疗设备, 2016, 31 (11) : 9 - 13
  • [9] Increasing the Accuracy of Dose Calculation On Cone-Beam Imaging Using Deformable Image Registration in the Case of Prostate Translation
    Fillion, O.
    Gingras, L.
    Archambault, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 402 - 402
  • [10] Dose/volume-based evaluation of the accuracy of deformable image registration for the rectum and bladder
    Thor, Maria
    Bentzen, Lise
    Elstrom, Ulrik V.
    Petersen, Jorgen B. B.
    Muren, Ludvig Paul
    ACTA ONCOLOGICA, 2013, 52 (07) : 1411 - 1416