Dose/volume-based evaluation of the accuracy of deformable image registration for the rectum and bladder

被引:29
|
作者
Thor, Maria [1 ]
Bentzen, Lise [2 ]
Elstrom, Ulrik V. [1 ]
Petersen, Jorgen B. B. [1 ]
Muren, Ludvig Paul [1 ,2 ,3 ]
机构
[1] Aarhus Univ Hosp, Dept Med Phys, DK-8000 Aarhus C, Denmark
[2] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
[3] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
关键词
PROSTATE-CANCER; CONTOUR PROPAGATION; DOSE-ESCALATION; LYMPH-NODES; RADIOTHERAPY; ORGAN; ROBUSTNESS; ALGORITHM; THERAPY; MOTION;
D O I
10.3109/0284186X.2013.814151
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose. Deformable image registration (DIR) is a key component of image-guided and adaptive strategies in radiotherapy. DIR based on image intensities alone is promising for online applications, but is challenged in regions with low intensity gradients. In this study we have investigated the performance of intensity-based DIR applied to contour propagation of the rectum and bladder, focusing on the consequences in terms of dose/volume parameters. Material and methods. The rectum and bladder volumes were delineated in the planning computed tomography (pCT) scan and in 8-9 repeat CTs (Vmanual) for nine prostate cancer patients. The volumes from the pCT were propagated onto the repeat CTs using intensity-based DIR (Vprop). Dose/volume parameters for Vmanual and Vprop were derived by dose re-calculations following rigid registration on prostate fiducials. Linear regression was used to identify qualitative and quantitative volumetric measures of the DIR performance being associated with the differences in dose/volume parameters. Results. The median differences in dose/volume parameters assessed for Vprop and Vmanual were modest, but individual differences similar to 7 Gy were seen. The observed differences in dose/volume parameters showed strong correlations to the measures of the DIR performance as well as with the volume variations, most pronounced for the rectum (R-2 = 0.63-0.85; p <= 0.05). Conclusion. Limitations in the intensity-based DIR algorithm resulted in large individual differences in dose/volume parameters between propagated and manually segmented volumes, which were correlated with volumetric measures of the DIR performance.
引用
收藏
页码:1411 / 1416
页数:6
相关论文
共 50 条
  • [1] Evaluation of four volume-based image registration algorithms
    Chu, J.
    Zhang, Y.
    Hsi, W.
    Khan, A.
    Mehta, P.
    Bernard, D.
    Abrams, R.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2353 - 2353
  • [2] EVALUATION OF FOUR VOLUME-BASED IMAGE REGISTRATION ALGORITHMS
    Zhang, Yunkai
    Chu, James C. H.
    Hsi, Wenchien
    Khan, Atif J.
    Mehta, Parthiv S.
    Bernard, Damian B.
    Abrams, Ross A.
    [J]. MEDICAL DOSIMETRY, 2009, 34 (04) : 317 - 322
  • [3] A Dose-Based Metric to Assess the Accuracy of Deformable Image Registration
    Annis, S.
    Heath, E.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 155 - 155
  • [4] Evaluation of volume-based and surface-based brain image registration methods
    Klein, Arno
    Ghosh, Satrajit S.
    Avants, Brian
    Yeo, B. T. T.
    Fischl, Bruce
    Ardekani, Babak
    Gee, James C.
    Mann, J. J.
    Parsey, Ramin V.
    [J]. NEUROIMAGE, 2010, 51 (01) : 214 - 220
  • [5] Uncertainties of deformable image registration for dose accumulation of high-dose regions in bladder and rectum in locally advanced cervical cancer
    Jamema, Swamidas V.
    Mahantshetty, Umesh
    Andersen, Else
    Noe, Karsten O.
    Sorensen, Thomas S.
    Kallehauge, Jesper F.
    Shrivastava, Shyam K.
    Deshpande, Deepak D.
    Tanderup, Karl
    [J]. BRACHYTHERAPY, 2015, 14 (06) : 953 - 962
  • [6] Dosimetric impact of bladder changes in prostate VMAT based on dose deformable image registration
    Gonzalez Pose, A.
    Vazquez Barreiro, B.
    Vazquez Rodriguez, J. S.
    Andrade Alvarez, B.
    Teijeiro Garcia, A.
    Blanco Ledo, A. B.
    Riveira Martin, M.
    Dorado Dorado, R.
    Lopez Medina, A.
    Salgado Fernandez, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1267 - S1268
  • [7] An Anthropopathic Deformable Phantom for Geometric and Dose Accumulation Accuracy Validation of Deformable Image Registration
    Liao, Y.
    Chen, H.
    Chen, J.
    Gu, X.
    Zhen, X.
    Zhou, L.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3884 - 3884
  • [8] Evaluation of the accuracy of deformable image registration on MRI with a physical phantom
    Wu, Richard Y.
    Liu, Amy Y.
    Yang, Jinzhong
    Williamson, Tyler D.
    Wisdom, Paul G.
    Bronk, Lawrence
    Gao, Song
    Grosshan, David R.
    Fuller, David C.
    Gunn, Gary B.
    Ronald Zhu, X.
    Frank, Steven J.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 166 - 173
  • [9] Experimental Validation of Dose Warping Accuracy From Deformable Image Registration
    Varadhan
    Hui, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Evaluation of rectum and bladder dose accumulation from external beam radiotherapy and brachytherapy for cervical cancer using two different deformable image registration techniques
    Kadoya, Noriyuki
    Miyasaka, YuYa
    Yamamoto, Takaya
    Kuroda, Yoshihiro
    Ito, Kengo
    Chiba, Mizuki
    Nakajima, Yujiro
    Takahashi, Noriyoshi
    Kubozono, Masaki
    Umezawa, Rei
    Dobashi, Suguru
    Takeda, Ken
    Jingu, Keiichi
    [J]. JOURNAL OF RADIATION RESEARCH, 2017, 58 (05) : 720 - 728