Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes

被引:60
|
作者
Kriechbaum, K
Findl, O
Kiss, B
Sacu, S
Petternel, V
Drexler, W
机构
[1] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
[2] Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
来源
关键词
D O I
10.1016/S0886-3350(02)01822-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare anterior chamber depth (ACD) measurements in phakic and pseudophakic eyes using a slit-beam photographic technique (IOLMaster, Carl Zeiss Meditec AG) with those obtained with the laboratory prototype version of partial coherence interferometry (PCI) and with conventional applanation ultrasound in phakic eyes. Setting: Department of Ophthalmology, Vienna General Hospital, Vienna University, Vienna, Austria. Methods: Thirty-three ACDs of 28 patients with age-related cataract were measured preoperatively with a slit-beam photographic technique (IOLMaster) and the prototype version of PCI. In 24 eyes, the ACID was also assessed with applanation ultrasound. In addition, 34 ACDs of 18 pseudophakic patients in a different study population were examined postoperatively with the IOLMaster and PCI Results: The median ACD in the phakic eyes was 3.06 mm (range 1.93 to 3.90 mm) with the IOLMaster, 3.09 mm with PCI (range 1.49 to 4.06 mm), and 2.87 mm (range 2.18 to 3.33 mm) with applanation ultrasound. The precision was 0.005 mm for PCI and 0.015 mm for IOLMaster measurement. The median difference between the IOLMaster and PCI ACD biometry was 0.01 mm +/- 0.14 (SD) (range -0.44 to 0.17 mm) (P = .71). In pseudophakic eyes, the 2 methods showed a median difference of -0.22 mm (range -0.45 to 1.99 mm) (P > .1) and did not correlate (r = 0.21; P > .2). Conclusions: In phakic eyes, the difference between IOLMaster and PCI measurements was small and not statistically significant. In pseudophakic eyes, the difference was larger and the methods did not correlate. (C) 2003 ASCRS and ESCRS.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 50 条
  • [21] Comparison of objective accommodation in phakic and pseudophakic eyes between age groups
    Byunghoon Chung
    Seonghee Choi
    Yong Woo Ji
    Eung Kweon Kim
    Kyoung Yul Seo
    Tae-im Kim
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 575 - 582
  • [22] Comparison of objective accommodation in phakic and pseudophakic eyes between age groups
    Chung, Byunghoon
    Choi, Seonghee
    Ji, Yong Woo
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Tae-im
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (03) : 575 - 582
  • [23] ULTRASOUND BIOMICROSCOPY IN ANTERIOR-CHAMBER PHAKIC EYES IMPLANTS
    ALLEMANN, N
    CHAMON, W
    VANZELLA, LL
    NOSE, RM
    NOSE, W
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S797 - S797
  • [24] Posterior Chamber Phakic Intraocular Lens Implantation in Eyes with an Anterior Chamber Depth of Less Than 3 mm: A Multicenter Study
    Kazutaka Kamiya
    Kimiya Shimizu
    Akihito Igarashi
    Yoshihiro Kitazawa
    Takashi Kojima
    Tomoaki Nakamura
    Kazuo Ichikawa
    Scientific Reports, 8
  • [25] Posterior Chamber Phakic Intraocular Lens Implantation in Eyes with an Anterior Chamber Depth of Less Than 3 mm: A Multicenter Study
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    Kitazawa, Yoshihiro
    Kojima, Takashi
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    SCIENTIFIC REPORTS, 2018, 8
  • [26] Selective laser trabeculoplasty in phakic and pseudophakic eyes
    Werner, Mark
    Smith, M. Fran
    Doyle, J. William
    OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (03) : 182 - 188
  • [27] Lens-thickness correlation with pseudophakic anterior chamber depth
    Galvis, Virgilio
    Tello, Alejandro
    Frederick, Gabriel A.
    Serrano, Andres
    Camacho, Paul A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 645 - 646
  • [28] Calculation of ocular magnification in phakic and pseudophakic eyes based on anterior segment OCT data
    Langenbucher, Achim
    Szentmary, Nora
    Leydolt, Christina
    Cayless, Alan
    Schwarzenbacher, Luca
    Nagy, Zoltan Zsolt
    Menapace, Rupert
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2021, 41 (04) : 831 - 841
  • [29] Glare sensitivity in patients with phakic and pseudophakic eyes
    Eisenmann, D
    Jacobi, FK
    Dick, B
    Jacobi, KW
    Pabst, W
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 208 (02) : 87 - 92
  • [30] The effect of Nd:YAGAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes
    Khambhiphant, Bharkbhum
    Liumsirijarern, Chayata
    Saehout, Piyada
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 557 - 561