摘要
Background: Transportation of the critically ill or injured war fighter requires the coordinated care and judicious use of resources. Availability of oxygen (O-2) supplies for the mechanically ventilated patient is crucial. Size and weight of cylinders makes transport difficult and presents an increased risk of fire. A proposed solution is to use a portable oxygen concentrator (POC) for mechanical ventilation. We tested the SeQual Eclipse II POC paired with the Impact 754 and Pulmonetics LTV-1200 ventilators in the laboratory and evaluated the fraction of inspired oxygen (FIO2) across a range of minute volumes. Methods: Each ventilator was attached to a test lung and pressure, volume, flow, and inspired oxygen (FIO2) was measured by a gas or flow analyzer. Ventilators were tested at a tidal volume (V-T) of 500 mL; an inspiratory time of 1.0 second; respiratory rates of 10, 20, and 30 breaths per minute; and positive end-expiratory pressure of 0 and 10 cm H2O. The LTV 1200 was tested with and without the expiratory bias flow. The Eclipse II was modified to provide pulse dosing on inspiration at 3 volumes (64, 128, and 192 mL) and continuous flow at 1 L/min to 3 L/min. Six combinations of ventilator settings were used with each POC setting for evaluation. O-2 was injected at the ventilator gas outlet and patient y-piece for pulse dose and continuous flow. Additionally, continuous flow O-2 was injected into the oxygen inlet port of the LTV 1200, and a reservoir bag, on the inlet port of the Impact 754. All tests were done with both ventilators using continuous flow, wall source O-2 as a control. We also measured the FIO2 with the concentrator on the highest pulse dose setting while decreasing ventilator V-T to compensate for the added volume. Results: The delivered FIO2 was highest when oxygen was injected into the ventilator circuit at the patient y-piece using pulse dosing, with the VT corrected. The next highest FIO2 was with continuous flow at the inlet (LTV), and reservoir (Impact). Electrical power consumption was less during pulse dose operation. Summary: Oxygen is a finite resource, which is cumbersome to transport and may present a fire hazard. The relatively high FIO2 delivered by the POC makes this method of O-2 delivery a viable alternative to O-2 cylinders. However, patients requiring an FIO2 of 1.0 would require additional compressed oxygen. This system allows O-2 delivery up to 76% solely using electricity. An integrated ventilator or POC capable of automatically compensating V-T for POC output is desirable. Further patient testing needs to be done to validate these laboratory findings.
引用
收藏
页码:S87 / S93
页数:7
相关论文
共 50 条
  • [21] The use of dual oxygen concentrator system for mechanical ventilation during COVID-19 pandemic in Sabah, Malaysia
    Cheah, Phee Kheng
    Steven, Evelyn Marie
    Ng, Khai Keam
    Hashim, Muammar Iqbal
    Abdul Kadir, Mohamed Hakimi
    Roder, Nicholas Paul
    INTERNATIONAL JOURNAL OF EMERGENCY MEDICINE, 2021, 14 (01)
  • [22] The use of dual oxygen concentrator system for mechanical ventilation during COVID-19 pandemic in Sabah, Malaysia
    Phee Kheng Cheah
    Evelyn Marie Steven
    Khai Keam Ng
    Muammar Iqbal Hashim
    Mohamed Hakimi Abdul Kadir
    Nicholas Paul Roder
    International Journal of Emergency Medicine, 2021, 14
  • [23] MONITORING INSPIRED OXYGEN PRESSURES DURING MECHANICAL VENTILATION
    HARRIS, TM
    GRAY, M
    PETTY, TL
    MUELLER, R
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 206 (13): : 2885 - &
  • [24] Conservative Oxygen Therapy during Mechanical Ventilation in the ICU
    Mackle, Diane
    Bellomo, M. N. Rinaldo
    Bailey, Michael
    Beasley, Richard
    Deane, Adam
    Eastwood, Glenn
    Finfer, Simon
    Freebairn, Ross
    King, Victoria
    Linke, Natalie
    Litton, Edward
    McArthur, Colin
    McGuinness, Shay
    Panwar, Rakshit
    Young, Paul
    NEW ENGLAND JOURNAL OF MEDICINE, 2020, 382 (11): : 989 - 998
  • [25] EFFICIENCY, ARGON ACCUMULATION, AND ACCURACY OF ANESTHETIC GAS MONITORING DURING MECHANICAL VENTILATION IN A CIRCLE SYSTEM USING AN OXYGEN CONCENTRATOR
    RATHGEBER, J
    ZUCHNER, K
    KIETZMANN, D
    KRAUS, E
    ANAESTHESIST, 1995, 44 (09): : 643 - 650
  • [26] Maximizing aerosol delivery during mechanical ventilation: go with the flow and go slow
    Rajiv Dhand
    Intensive Care Medicine, 2003, 29 : 1041 - 1042
  • [27] Maximizing aerosol delivery during mechanical ventilation: go with the flow and go slow
    Dhand, R
    INTENSIVE CARE MEDICINE, 2003, 29 (07) : 1041 - 1042
  • [28] Cardiopulmonary Function and Oxygen Delivery During Total Liquid Ventilation
    Tsagogiorgas, Charalambos
    Alb, Markus
    Herrmann, Peter
    Quintel, Michael
    Meinhardt, Juergen P.
    PEDIATRIC PULMONOLOGY, 2011, 46 (10) : 964 - 975
  • [29] Is the portable concentrator the best solution to correct exercise Oxygen desaturation?
    Maduell, Ariadna Farre
    Alonso, Ana
    Penacoba, Patricia
    Morante, Fatima
    Guell, Maria Rosa
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [30] Oxygen targets during mechanical ventilation: Are we aiming to high?
    Eastwood, Glenn M.
    AUSTRALIAN CRITICAL CARE, 2014, 27 (03) : 107 - 107