Comparison of active filter performance for harmonic suppression for multiple non-linear loads

被引:0
|
作者
Raghavendiran, TA [1 ]
Thiruvengadam, S [1 ]
Udayakumar, K [1 ]
Chellamuthu, C [1 ]
Ramamurthy, S [1 ]
机构
[1] SriVenkateswara Coll Engn, Dept EEE, Sriperumbudur, India
关键词
total harmonic distortion; active filter; current compensation; power quality;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper compares the performance of the active filter based on the novel current compensation technique with that of the filter based on sliding mode control law method. The non-linear loads comprise a 600 wafts uncontrolled bridge rectifier and a 300 wafts electronic ballast. Experimental result shows that the reduction in the THD level is slightly better with current compensation method then with the sliding mode control method. If rapid load changes are taking place, the current compensation works better then the latter since the inverter output current tracks the compensating current signal closely.
引用
收藏
页码:2056 / 2060
页数:5
相关论文
共 50 条
  • [21] Intelligent localisation of multiple non-linear loads considering impact of harmonic state estimation accuracy
    Moradifar, Amir
    Foroud, Asghar Akbari
    Firouzjah, Khalil Gorgani
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (08) : 1943 - 1953
  • [22] Parallel active power filter for single- and three-phase non-linear loads
    Voncina, D
    Nastran, J
    ELECTRICAL ENGINEERING, 1998, 81 (04): : 217 - 223
  • [23] Comparative Study of Different Control Algorithms of Shunt Active Power Filter for Non-Linear Loads
    Shabib, Gaber
    Hussein, Mahmoud M.
    Hasseeb, Mahmoud Mohammed
    2017 NINETEENTH INTERNATIONAL MIDDLE-EAST POWER SYSTEMS CONFERENCE (MEPCON), 2017, : 1037 - 1043
  • [24] Active suppression of non-linear absorption quadratically non-linear media without dispersion
    Gavrilov, AM
    Savitsekii, OA
    RUSSIAN ULTRASONICS, 1997, 27 (04): : 223 - 233
  • [25] Active power filter for harmonic and reactive power compensation in three-phase, four-wire systems supplying non-linear loads
    Singh, B
    Al-Haddad, K
    Chandra, A
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1998, 8 (02): : 139 - 145
  • [26] Hybrid inductive and active filtering method for damping harmonic resonance in distribution network with non-linear loads
    Li, Yong
    Liu, Fang
    Saha, Tapan Kumar
    Krause, Olav
    Cao, Yijia
    IET POWER ELECTRONICS, 2015, 8 (09) : 1616 - 1624
  • [28] Reactive Power and Current Harmonic Control Using a Dual Hybrid Power Filter for Unbalanced Non-Linear Loads
    Limongi, Leonardo Rodrigues
    Bradaschia, Fabricio
    de Oliveira Lima, Calebe Hermann
    Cavalcanti, Marcelo Cabral
    ENERGIES, 2018, 11 (06)
  • [29] HARMONIC INTERACTION OF A STATIC VAR COMPENSATOR WITH AC POWER SYSTEM CONTAINING MULTIPLE NON-LINEAR LOADS
    Kraimia, Mohamed Nassim
    Boudour, Mohamed
    ENGINEERING REVIEW, 2020, 40 (03) : 21 - 31
  • [30] Determining harmonic characteristics of typical single phase non-linear loads
    Umeh, KC
    Mohamed, A
    Mohamed, R
    SCORED 2003: STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT, PROCEEDINGS: NETWORKING THE FUTURE MIND IN CONVERGENCE TECHNOLOGY, 2003, : 413 - 419