Therapeutic impact of [18F]fluoride positron-emission tomography/computed tomography on patients with unclear foot pain

被引:37
|
作者
Fischer, Dorothee Rita [1 ]
Maquieira, Gerardo J. [2 ]
Espinosa, Norman [2 ]
Zanetti, Marco [3 ]
Hesselmann, Rolf [1 ]
Johayem, Anass [1 ]
Hany, Thomas F. [1 ]
von Schulthess, Gustav K. [1 ]
Strobel, Klaus [1 ]
机构
[1] Univ Zurich Hosp, Dept Nucl Med, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Dept Orthopaed, Zurich, Switzerland
[3] Univ Zurich, Dept Radiol, Zurich, Switzerland
关键词
F-18]fluoride PET/CT; Foot pain; Fluoride uptake; Therapeutic impact; PLANAR BONE-SCINTIGRAPHY; F-18-FLUORIDE PET; PROSTATE-CANCER; LUNG-CANCER; BACK-PAIN; METASTASES; MANAGEMENT; SHORTAGE; ONCOLOGY; SPECT;
D O I
10.1007/s00256-010-0875-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To evaluate the therapeutic impact of [F-18]fluoride positron-emission tomography/computed tomography ([F-18]fluoride PET/CT) imaging on patients with unclear foot pain. Twenty-eight patients were prospectively included in this study. Therapeutic management was defined by two experienced dedicated foot surgeons before and after [F-18]fluoride PET/CT imaging. Twenty-six patients underwent cross-sectional imaging [CT, magnetic resonance (MR)] prior to PET/CT. A retrospective analysis of the magnetic resonance imaging (MRI) diagnoses was performed when a therapy change occurred after PET/CT imaging. In 13/28 (46%) patients therapeutic management was changed due to PET/CT results. Management changes occurred in patients with the following diagnoses: os trigonum syndrome; sinus tarsi syndrome; os tibiale externum syndrome; osteoarthritis of several joints; non-consolidated fragments; calcaneo-navicular coalition; plantar fasciitis; insertional tendinopathy; suggestion of periostitis; neoarticulations between metatarsal bones. Os trigonum, os tibiale externum, subtalar osteoarthritis and plantar fasciitis were only seen to be active on PET/CT images but not on MR images. [F-18]fluoride PET/CT has a substantial therapeutic impact on management in patients with unclear foot pain.
引用
下载
收藏
页码:987 / 997
页数:11
相关论文
共 50 条
  • [21] Feasibility of Coronary 18F-Sodium Fluoride Positron-Emission Tomography Assessment With the Utilization of Previously Acquired Computed Tomography Angiography
    Kwiecinski, Jacek
    Adamson, Philip D.
    Lassen, Martin L.
    Doris, Mhairi K.
    Moss, Alastair J.
    Cadet, Sebastian
    Jansen, Maurits A.
    Dey, Damini
    Lee, Sang-Eun
    Yun, Mijin
    Chang, Hyuk-Jae
    Dweck, Marc R.
    Newby, David E.
    Berman, Daniel S.
    Slomka, Piotr J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (12) : e008325
  • [22] Assessment of successful incorporation of cages after cervical or lumbar intercorporal fusion with [(18)F]fluoride positron-emission tomography/computed tomography
    Dorothee R. Fischer
    K. Zweifel
    V. Treyer
    R. Hesselmann
    A. Johayem
    K. D. M. Stumpe
    G. K. von Schulthess
    T. F. Hany
    K. Strobel
    European Spine Journal, 2011, 20 : 640 - 648
  • [23] Positron-emission tomography/computed tomography: artifacts and pitfalls in cancer patients
    Gorospe Sarasua, L.
    Echeveste Aizpurua, J.
    Raman, S.
    RADIOLOGIA, 2006, 48 (04): : 189 - 204
  • [24] OPTIMIZATION AND REPRODUCIBILITY OF 18F-FLUORIDE POSITRON EMISSION TOMOGRAPHY AND COMPUTED TOMOGRAPHY IN PATIENTS WITH AORTIC STENOSIS
    Pawade, Tania
    Cartlidge, Timothy R.
    Newby, David
    Dweck, Marc
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1764 - 1764
  • [25] OPTIMISATION AND REPRODUCIBILITY OF 18F-FLUORIDE POSITRON EMISSION TOMOGRAPHY AND COMPUTED TOMOGRAPHY IN PATIENTS WITH AORTIC STENOSIS
    Pawade, Tania
    Cartlidge, Timothy
    Newby, David
    Marc, Dweck
    HEART, 2016, 102 : A82 - A82
  • [26] The Reproducibility and Optimisation of 18F-Fluoride Positron Emission Tomography and Computed Tomography in Patients with Aortic Stenosis
    Pawade, Tania A.
    Cartlidge, Timothy R.
    Newby, David E.
    Dweck, Marc R.
    CARDIOLOGY, 2016, 134 (02) : 265 - 266
  • [27] [18F]Difluorocarbene for positron emission tomography
    Sap, Jeroen B. I.
    Meyer, Claudio F.
    Ford, Joseph
    Straathof, Natan J. W.
    Durr, Alexander B.
    Lelos, Mariah J.
    Paisey, Stephen J.
    Mollner, Tim A.
    Hell, Sandrine M.
    Trabanco, Andres A.
    Genicot, Christophe
    Am Ende, Christopher W.
    Paton, Robert S.
    Tredwell, Matthew
    Gouverneur, Veronique
    NATURE, 2022, 606 (7912) : 102 - +
  • [28] [18F]Difluorocarbene for positron emission tomography
    Sap, Jeroen
    Gouverneur, Veronique
    Meyer, Claudio
    Ford, Joseph
    Straathof, Natan
    Durr, Alexander
    Lelos, Mariah
    Paisey, Stephen
    Mollner, Tim
    Hell, Sandrine
    Trabanco, Andres
    amEnde, Christopher
    Paton, Robert
    Tredwell, Matthew
    NUCLEAR MEDICINE AND BIOLOGY, 2023, 126 : S69 - S70
  • [29] [18F]Difluorocarbene for positron emission tomography
    Jeroen B. I. Sap
    Claudio F. Meyer
    Joseph Ford
    Natan J. W. Straathof
    Alexander B. Dürr
    Mariah J. Lelos
    Stephen J. Paisey
    Tim A. Mollner
    Sandrine M. Hell
    Andrés A. Trabanco
    Christophe Genicot
    Christopher W. am Ende
    Robert S. Paton
    Matthew Tredwell
    Véronique Gouverneur
    Nature, 2022, 606 : 102 - 108
  • [30] Accuracy of 18F fluorodeoxyglucose positron emission tomography/computed tomography in staging of pediatric sarcomas
    Tateishi, Ukihide
    Hosono, Ako
    Makimoto, Tsushi
    Sakurada, Aine
    Terauchi, Takashi
    Arai, Yasuaki
    Imai, Yutaka
    Kim, Euishin Edmund
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2007, 29 (09) : 608 - 612