Ethanol/Trisodium citrate for hemodialysis catheter lock

被引:0
|
作者
Bell, AL
Gu, X
Burczynski, FJ
Vercaigne, LM
机构
[1] Univ Manitoba, Fac Pharm, Off 407B, Winnipeg, MB R3T 2N2, Canada
[2] Hlth Sci Ctr, Manitoba Renal Program, Winnipeg, MB, Canada
关键词
ethanol; citrate; catheter; lock; hemodialysis;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aims: The objective of this study was to confirm the compatibility of ethanol and 4% trisodium citrate (TSC) for potential use as a catheter locking solution. Methods: Increasing concentrations of ethanol were combined with 4% TSC in glass test tubes and stored at 37degreesC over 72 hours. Each tube was visually inspected to determine the highest compatible concentration. To confirm visual compatibility, HPLC analysis was used to compare the concentration of TSC in control solutions (n = 6) to solutions containing both TSC and the highest concentration of ethanol that was visually compatible (n = 6). Compatibility in carbothane hemodialysis catheters was then confirmed in vitro. Results: Results of the compatibility tests indicated that 30% ethanol was the maximum concentration visually compatible with 4% TSC. Ethanol concentrations of 35% or above form a crystalline precipitate in the glass test tubes within 72 hours. HPLC analysis showed no difference in the concentration of TSC in the control solutions compared to the TSC/ethanol solutions when incubated in glass test tubes. A slight, but statistically significant increase in the TSC concentration (1.27%; p < 0.0001) was observed when the ethanol/TSC solution was incubated in carbothane hemodialysis catheters. This slight increase may be due to ethanol absorption into the catheter polymer. Further studies are underway to determine if an ethanol/TSC lock affects the mechanical properties of these carbothane hemodialysis catheters. Conclusions: We conclude that 30% ethanol is compatible with 4% trisodium citrate in carbothane hemodialysis catheters in vitro. Until the lock's affect on carbothane hemodialysis catheters is known, it cannot yet be recommended for clinical use.
引用
收藏
页码:369 / 373
页数:5
相关论文
共 50 条
  • [21] HEPARIN VERSUS SODIUM BICARBONATE CATHETER LOCK SOLUTION: AN ALTERNATIVE LOCK HEMODIALYSIS CATHETER?
    Partipilo, Francesca
    Detomaso, Francesco
    Pietanza, Stefania
    Gernone, Giuseppe
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2021, 36
  • [22] ETHANOL LOCK IN THE MANAGEMENT OF CATHETER OCCLUSION
    PENNINGTON, CR
    PITHIE, AD
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1987, 11 (05) : 507 - 508
  • [23] Ethanol Lock and Risk of Hemodialysis Catheter Infection in Critically III Patients A Randomized Controlled Trial
    Souweine, Bertrand
    Lautrette, Alexandre
    Gruson, Didier
    Canet, Emmanuel
    Klouche, Kada
    Argaud, Laurent
    Bohe, Julien
    Garrouste-Orgeas, Maite
    Mariat, Christophe
    Vincent, Francois
    Cayot, Sophie
    Cointault, Olivier
    Lepape, Alain
    Guelon, Dominique
    Darmon, Michael
    Vesin, Aurelien
    Caillot, Nicolas
    Schwebel, Carole
    Boyer, Alexandre
    Azoulay, Elie
    Bouadma, Lila
    Timsit, Jean-Francois
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191 (09) : 1024 - 1032
  • [24] Novel catheter lock solution in prevention of hemodialysis catheter complications
    Lustig, Ahuva
    Aflalu, Shahar
    JOURNAL OF CLINICAL PHARMACOLOGY, 2011, 51 (09): : 1341 - 1341
  • [25] Glyceryl Trinitrate Complements Citrate and Ethanol in a Novel Antimicrobial Catheter Lock Solution To Eradicate Biofilm Organisms
    Rosenblatt, Joel
    Reitzel, Ruth
    Dvorak, Tanya
    Jiang, Ying
    Hachem, Ray Y.
    Raad, Issam I.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2013, 57 (08) : 3555 - 3560
  • [26] Superior antimicrobial activity of trisodium citrate over heparin for catheter locking
    Weijmer, MC
    Debets-Ossenkopp, YJ
    van de Vondervoort, FJ
    ter Wee, PM
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 (12) : 2189 - 2195
  • [27] HYPERTONIC CITRATE CATHETER LOCK CAUSES PROTEIN PRECIPITATION
    Schilcher, G.
    Ribitsch, W.
    Horina, J. H.
    Rosenkranz, A. R.
    Polaschegg, H. D.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 672 - 672
  • [28] A Taurolidine-Citrate-Heparin Lock Solution Effectively Eradicates Pathogens From the Catheter Biofilm in Hemodialysis Patients
    Zwiech, Rafal
    Adelt, Maria
    Chrul, Slawomir
    AMERICAN JOURNAL OF THERAPEUTICS, 2016, 23 (02) : E363 - E368
  • [29] Loss of antimicrobial effect of trisodium citrate due to 'lock' spillage from haemodialysis catheters
    Schilcher, Gernot
    Schneditz, Daniel
    Ribitsch, Werner
    Horina, Joerg H.
    Hoenigl, Martin
    Valentin, Thomas
    Rosenkranz, Alexander R.
    Krause, Robert
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 (04) : 914 - 919
  • [30] Comparative effectiveness of 30 % trisodium citrate and heparin lock solution in preventing infection and dysfunction of hemodialysis catheters: a randomized controlled trial (CITRIM trial)
    Barcellos, Franklin Correa
    Nunes, Bruno Pereira
    Valle, Luciana Jorge
    Lopes, Thiago
    Orlando, Bianca
    Scherer, Cintia
    Nunes, Marcia
    Duarte, Gabriela Araujo
    Bohlke, Maristela
    INFECTION, 2017, 45 (02) : 139 - 145