Low-pressure membrane integrity tests for drinking water treatment: A review

被引:139
|
作者
Guo, H. [1 ]
Wyart, Y. [1 ]
Perot, J. [2 ]
Nauleau, F. [2 ]
Moulin, P. [1 ]
机构
[1] Univ Paul Cezanne Aix Marseille, Lab Mecan Modelisat & Proc Propres, CNRS, M2P2,UMR 6181, F-13545 Aix En Provence 04, France
[2] SAUR, F-78064 St Quentin En Yvelines, France
关键词
Low-pressure membrane; Microfiltration; Ultrafiltration; Membrane integrity; Drinking water; ULTRAFILTRATION MEMBRANES; NANOSCALE PROBES; TREATMENT-PLANT; MICROFILTRATION; FILTRATION; REMOVAL; SYSTEMS; FLUX; POROSIMETRY; SENSOR;
D O I
10.1016/j.watres.2009.09.032
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-pressure membrane systems, including microfiltration (MF) and ultrafiltration (UF) membranes, are being increasingly used in drinking water treatments due to their high level of pathogen removal. However, the pathogen will pass through the membrane and contaminate the product if the membrane integrity is compromised. Therefore, an effective on-line integrity monitoring method for MF and UF membrane systems is essential to guarantee the regulatory requirements for pathogen removal. A lot of works on low-pressure membrane integrity tests have been conducted by many researchers. This paper provides a literature review about different low-pressure membrane integrity monitoring methods for the drinking water treatment, including direct methods (pressure-based tests, acoustic sensor test, liquid porosimetry, etc.) and indirect methods (particle counting, particle monitoring, turbidity monitoring, surrogate challenge tests). Additionally, some information about the operation of membrane integrity tests is presented here. It can be realized from this review that it remains urgent to develop an alternative on-line detection technique for a quick, accurate, simple, continuous and relatively inexpensive evaluation of low-pressure membrane integrity. To better satisfy regulatory requirements for drinking water treatments, the characteristic of this ideal membrane integrity test is proposed at the end of this paper. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:41 / 57
页数:17
相关论文
共 50 条
  • [1] Hydraulic backwashing for low-pressure membranes in drinking water treatment: A review
    Chang, Haiqing
    Liang, Heng
    Qu, Fangshu
    Liu, Baicang
    Yu, Huarong
    Du, Xing
    Li, Guibai
    Snyder, Shane A.
    JOURNAL OF MEMBRANE SCIENCE, 2017, 540 : 362 - 380
  • [2] Low-Pressure Membrane for Water Treatment Applications
    AlFannakh, Huda
    Abdallah, Heba
    Ibrahim, S. S.
    Souayeh, Basma
    INTERNATIONAL JOURNAL OF POLYMER SCIENCE, 2020, 2020
  • [3] Evaluation of a low-pressure membrane filtration for drinking water treatment: pretreatment by coagulation/sedimentation for the MF membrane
    Moon, Jihee
    Kang, Moon-Sun
    Lim, Jae-Lim
    Kim, Choong-Hwan
    Park, Hee-Deung
    DESALINATION, 2009, 247 (1-3) : 271 - 284
  • [4] A review of the impact of chemical pretreatment on low-pressure water treatment membranes
    Farahbakhsh, K
    Svrcek, C
    Guest, RK
    Smith, DW
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND SCIENCE, 2004, 3 (04) : 237 - 253
  • [5] WATER TREATMENT USING HYBRID METHOD OF COAGULATION AND LOW-PRESSURE MEMBRANE FILTRATION
    Konieczny, Krystyna
    Rajca, Mariola
    Bodzek, Michal
    Kwiecinska, Anna
    ENVIRONMENT PROTECTION ENGINEERING, 2009, 35 (01): : 5 - 22
  • [6] Impact of PAC Fines in Fouling of Polymeric and Ceramic Low-Pressure Membranes for Drinking Water Treatment
    Oligny, Laurent
    Berube, Pierre R.
    Barbeau, Benoit
    MEMBRANES, 2016, 6 (03)
  • [7] Monitoring the integrity of low-pressure membranes
    Farahbakhsh, Khosrow
    Adham, Samer S.
    Smith, Daniel W.
    Farahbakhsh, K. (khosrow@ualberta.ca), 1600, American Water Works Association (95): : 95 - 107
  • [8] LOW-PRESSURE MEMBRANES - ASSESSING INTEGRITY
    ADHAM, SS
    JACANGELO, JG
    LAINE, JM
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1995, 87 (03): : 62 - 75
  • [9] Rejection characteristics of organic and inorganic pollutants by ultra low-pressure nanofiltration of surface water for drinking water treatment
    Thanuttamavong, M
    Yamamoto, K
    Oh, JI
    Choo, KH
    Choi, SJ
    DESALINATION, 2002, 145 (1-3) : 257 - 264
  • [10] Monitoring the integrity of low-pressure monitoring
    Farahbakhsh, K
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2003, 95 (06): : 95 - 107