Evaluation of a low-pressure membrane filtration for drinking water treatment: pretreatment by coagulation/sedimentation for the MF membrane

被引:32
|
作者
Moon, Jihee [2 ]
Kang, Moon-Sun [2 ,4 ]
Lim, Jae-Lim [3 ]
Kim, Choong-Hwan [3 ]
Park, Hee-Deung [1 ]
机构
[1] Korea Univ, Sch Civil Environm & Architectural Engn, Seoul 136713, South Korea
[2] KOLON E&C, R&D Inst, Environm Res Team, Yongin 449815, Gyeonggi, South Korea
[3] Korea Water Resources Corp, Water Res Ctr, Taejon 305730, South Korea
[4] Sungkyunkwan Univ, Dept Civil Architectural & Environm Syst Engn, Suwon 440746, South Korea
关键词
Aluminum-based coagulant; Coagulation; Fouling; Immersed microfiltration; Sedimentation; NATURAL ORGANIC-MATTER; MICROFILTRATION; ALUMINUM; PERFORMANCE; COAGULATION; REMOVAL; SYSTEM; MODEL;
D O I
10.1016/j.desal.2008.12.030
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The immersed microfiltration (MF) membrane system combined with coagulation and sedimentation as a pretreatment was evaluated with respect to membrane flux, dissolved organic matter (DOM) removal, and the influence on membrane fouling properties. The pretreatment-combined membrane system demonstrates better performance in water production and DOM control than the direct filtration system without pretreatment. The pretreatment with coagulation and sedimentation improved the membrane performance for a sudden increase of solid loading and severe fluctuation of source water properties: in particular, the sedimentation step exhibited the capability of buffering the sudden shock of solid loading to the membrane, resulting in maintaining the stable flux and transmembrane pressure (TMP) in the membrane filtration. Even though pretreatment improved membrane performance, somewhat serious fouling was observed in the membrane due to the residual coagulant. The aluminum-based coagulant formed an inorganic scale with the silica originated from the source water, and then this inorganic scale was expected to accumulate in the membrane and promote severe organic fouling. Thus, the residual aluminum-based coagulant should be controlled to reduce membrane fouling in order to develop an improved system operation and an improved process design for the proposed system.
引用
收藏
页码:271 / 284
页数:14
相关论文
共 50 条
  • [1] The effects of coagulation with MF/UF membrane filtration in drinking water treatment
    Jang, H. N.
    Lee, D. S.
    Ko, S. O.
    [J]. DESALINATION AND WATER TREATMENT, 2010, 19 (1-3) : 138 - 145
  • [2] WATER TREATMENT USING HYBRID METHOD OF COAGULATION AND LOW-PRESSURE MEMBRANE FILTRATION
    Konieczny, Krystyna
    Rajca, Mariola
    Bodzek, Michal
    Kwiecinska, Anna
    [J]. ENVIRONMENT PROTECTION ENGINEERING, 2009, 35 (01): : 5 - 22
  • [3] In-line coagulation with low-pressure membrane filtration
    Choi, KYJ
    Dempsey, BA
    [J]. WATER RESEARCH, 2004, 38 (19) : 4271 - 4281
  • [4] Low-pressure membrane filtration with unconventional coagulation regimes
    Choi, KY
    Dempsey, BA
    [J]. Leading-Edge Technology 2005 - Water Treatment, 2005, 5 (05): : 1 - 8
  • [5] The effect of coagulation with MF/UF membrane filtration for the removal of virus in drinking water
    Fiksdal, Liv
    Leiknes, TorOve
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) : 364 - 371
  • [6] Ion-exchange as a method of water pretreatment prior to low-pressure membrane filtration
    Kabsch-Korbutowicz, Malgorzata
    [J]. VIII National Polish Scientific Conference on Complex and Detailed Problems of Environmental Engineering, 2007, (23): : 515 - 526
  • [7] Reduced Low-Pressure Membrane Fouling by Inline Coagulation Pretreatment for a Colored River Water
    Ladouceur, Joseph D.
    Narbaitz, Roberto M.
    [J]. MEMBRANES, 2022, 12 (11)
  • [8] Low-pressure membrane integrity tests for drinking water treatment: A review
    Guo, H.
    Wyart, Y.
    Perot, J.
    Nauleau, F.
    Moulin, P.
    [J]. WATER RESEARCH, 2010, 44 (01) : 41 - 57
  • [9] Low-Pressure Membrane for Water Treatment Applications
    AlFannakh, Huda
    Abdallah, Heba
    Ibrahim, S. S.
    Souayeh, Basma
    [J]. INTERNATIONAL JOURNAL OF POLYMER SCIENCE, 2020, 2020
  • [10] Comparison of fouling mechanisms in low-pressure membrane (MF/UF) filtration of secondary effluent
    Muthukumaran, Shobha
    Jegatheesan, Jega V.
    Baskaran, Kanagaratnam
    [J]. DESALINATION AND WATER TREATMENT, 2014, 52 (4-6) : 650 - 662