Direct electron transfer of bilirubin oxidase at a carbon flow-through electrode

被引:13
|
作者
Wernert, Veronique [1 ]
Lebouin, Chrystelle [1 ]
Benoit, Virginie [1 ]
Gadiou, Roger [2 ]
de Poulpiquet, Anne [3 ]
Lojou, Elisabeth [3 ]
Denoyel, Renaud [1 ]
机构
[1] Aix Marseille Univ, CNRS, MADIREL, UMR 7246,Ctr St Jerome, F-13397 Marseille, France
[2] Aix Marseille Univ, CNRS, BIP, UMR 7281, 31 Chemin Joseph Aiguier, F-13402 Marseille 20, France
[3] Univ Haute Alsace, CNRS, IS2M, UMR 7361, Mulhouse, France
关键词
Bilirubin oxidase; Carbon; Isotherm; Enzymatic fuel cell; Flow-through electrode; DOUBLE-LAYER CAPACITANCE; ENZYMATIC FUEL-CELLS; SURFACE-AREA; PORE-SIZE; REDUCTION; DESIGN; BIOELECTROCATALYSIS; ADSORPTION; OXIDATION; CATALYSTS;
D O I
10.1016/j.electacta.2018.06.136
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The kinetics and isotherms of adsorption of Myrothecium verrucaria bilirubin oxidase (Mv BOD) on nanoporous carbons (CNP) and carbon nanofibers (CNF) were studied by the solution depletion method. The kinetics of adsorption of Mv BOD on both carbons are very fast, reaching equilibrium within 10 min and 30 min for CNP and CNF, respectively. The adsorption isotherms reveal a strong affinity between Mv BOD and both carbons. An original flow-through device based on electrodes filled with CNP and CNF connected to an UV-vis spectrophotometer was used to correlate the dioxygen catalytic current reduction to the amount of Mv BOD adsorbed on the carbons. It was shown that although the amount of BOD adsorbed on CNP is much lower than the amount adsorbed on CNF, the currents are comparable, suggesting that the Mv BOD orientation is more favourable for direct electron transfer in the case of CNP. Chronoamperometry experiments showed that the catalytic current is stable for a few days (70 h). It was emphasized by stop and flow experiments that the current is limited by mass transport inside the column. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 50 条
  • [41] CHARACTERISTICS OF A ROTATED POROUS FLOW-THROUGH ELECTRODE
    BLAEDEL, WJ
    WANG, J
    ANALYTICAL CHEMISTRY, 1980, 52 (11) : 1697 - 1700
  • [42] Glucose oxidase/colloidal gold nanoparticles immobilized in Nafion film on glassy carbon electrode: Direct electron transfer and electrocatalysis
    Zhao, Shuang
    Zhang, Kai
    Bai, Yu
    Yang, Weiwei
    Sun, Changqing
    BIOELECTROCHEMISTRY, 2006, 69 (02) : 158 - 163
  • [43] Direct Electron Transfer at a Glucose Oxidase–Chitosan-Modified Vulcan Carbon Paste Electrode for Electrochemical Biosensing of Glucose
    Sankararao Mutyala
    Jayaraman Mathiyarasu
    Applied Biochemistry and Biotechnology, 2014, 172 : 1517 - 1529
  • [44] Unadulterated glucose biosensor based on direct electron transfer of glucose oxidase encapsulated chitosan modified glassy carbon electrode
    Zhao, Changzhi
    Meng, Yi
    Shao, Changli
    Wan, Li
    Jiao, Kui
    ELECTROANALYSIS, 2008, 20 (05) : 520 - 526
  • [45] Direct Electron Transfer at a Glucose Oxidase-Chitosan-Modified Vulcan Carbon Paste Electrode for Electrochemical Biosensing of Glucose
    Mutyala, Sankararao
    Mathiyarasu, Jayaraman
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2014, 172 (03) : 1517 - 1529
  • [46] Direct electron transfer and electrocatalysis of glucose oxidase immobilized on glassy carbon electrode modified with Nafion and mesoporous carbon FDU-15
    Wang, Kunqi
    Yang, Hua
    Zhu, Lin
    Ma, Zhongsu
    Xing, Shenyang
    Lv, Qiang
    Liao, Jianhui
    Liu, Changpeng
    Xing, Wei
    ELECTROCHIMICA ACTA, 2009, 54 (20) : 4626 - 4630
  • [47] Bacterial cellulosecarbon nanotube composite as a biocompatible electrode for the direct electron transfer of glucose oxidase
    Kim, Young-Hoo
    Park, Saerom
    Won, Keehoon
    Kim, Hyung Joo
    Lee, Sang Hyun
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2013, 88 (06) : 1067 - 1070
  • [48] Analysis of factors governing direct electron transfer-type bioelectrocatalysis of bilirubin oxidase at modified electrodes
    So, Keisei
    Kitazumi, Yuki
    Shirai, Osamu
    Kano, Kenji
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 783 : 316 - 323
  • [49] Improved direct electron transfer-type bioelectrocatalysis of bilirubin oxidase using porous gold electrodes
    Takahashi, Yui
    Wanibuchi, Mizue
    Kitazumi, Yuki
    Shirai, Osamu
    Kano, Kenji
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 843 : 47 - 53
  • [50] Effects of N-linked glycans of bilirubin oxidase on direct electron transfer-type bioelectrocatalysis
    Suzuki, Yohei
    Itoh, Akira
    Kataoka, Kunishige
    Yamashita, Satoshi
    Kano, Kenji
    Sowa, Keisei
    Kitazumi, Yuki
    Shirai, Osamu
    BIOELECTROCHEMISTRY, 2022, 146