Optimizing the parameters of a four-detector polarimeter

被引:2
|
作者
Pakhomov, GV [1 ]
Safronich, IN [1 ]
Dorofeev, DL [1 ]
Zon, BA [1 ]
机构
[1] Voronezh State Univ, Voronezh 394693, Russia
关键词
Laser pulses - Light propagation - Matrix algebra - Optimization - Prisms;
D O I
10.1364/JOT.70.000166
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The design of a four-detector polarimeter has-been optimized in order to obtain the maximum measurement accuracy for the Stokes parameters of a light pulse. (C) 2003 Optical Society of America.
引用
收藏
页码:166 / 168
页数:3
相关论文
共 50 条
  • [31] USE OF A NITROGEN POLARIMETER AS A POLARIZED POTON DETECTOR
    STEBEN, JD
    BRUSSEL, MK
    NUCLEAR INSTRUMENTS & METHODS, 1966, 41 (01): : 73 - &
  • [32] A new NaI(Tl) four-detector layout for field contamination assessment using artificial neural networks and the Monte Carlo method for system calibration
    Moreira, M. C. F.
    Conti, C. C.
    Schirru, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 302 - 309
  • [33] Optimum detector arrangement of a Compton polarimeter using a clover detector for β-delayed γ rays
    Kojima, Y.
    Imai, K.
    Ohno, S.
    Chaya, R.
    Yamamoto, K.
    Shibata, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 990
  • [34] Prospective PET image quality gain calculation method by optimizing detector parameters
    Theodorakis, Lampros
    Loudos, George
    Prassopoulos, Vasilios
    Kappas, Constantine
    Tsougos, Ioannis
    Georgoulias, Panagiotis
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (12) : 1253 - 1263
  • [35] Modified transmission type four detectors polarimeter
    Kawabata, S
    NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION VII, 2004, 5524 : 337 - 344
  • [36] Four camera complete Stokes imaging polarimeter
    Pezzaniti, J. Larry
    Chenault, David
    Roche, Mike
    Reinhardt, John
    Pezzaniti, Joseph P.
    Schultz, Howard
    POLARIZATION: MEASUREMENT, ANALYSIS, AND REMOTE SENSING VIII, 2008, 6972
  • [37] ASTRONOMICAL POLARIMETER WITH 2-D DETECTOR ARRAYS
    STENFLO, JO
    POVEL, H
    APPLIED OPTICS, 1985, 24 (22): : 3893 - 3898
  • [38] APPLICATION OF A SECTORED GE(LI) DETECTOR AS A COMPTON POLARIMETER
    SIMPSON, J
    BUTLER, PA
    EKSTROM, LP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 204 (2-3): : 463 - 469
  • [39] Performance of a Ge-microstrip imaging detector and polarimeter
    Spillmann, U.
    Braeuning, H.
    Hess, S.
    Beyer, H.
    Stoehlker, Th.
    Dousse, J. -Cl.
    Protic, D.
    Krings, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (08):
  • [40] The Detector System for the Stratospheric Kinetic Inductance Polarimeter (Skip)
    B. R. Johnson
    P. A. R. Ade
    D. Araujo
    K. J. Bradford
    D. Chapman
    P. K. Day
    J. Didier
    S. Doyle
    H. K. Eriksen
    D. Flanigan
    C. Groppi
    S. Hillbrand
    G. Jones
    M. Limon
    P. Mauskopf
    H. McCarrick
    A. Miller
    T. Mroczkowski
    B. Reichborn-Kjennerud
    B. Smiley
    J. Sobrin
    I. K. Wehus
    J. Zmuidzinas
    Journal of Low Temperature Physics, 2014, 176 : 741 - 748