Use of Visible Spectrophotometry to Assess Tissue Oxygenation in the Colostomy Stoma

被引:3
|
作者
Singh, Daya B. [1 ]
Bain, Iain [1 ]
Harrison, David K. [1 ]
机构
[1] Univ Hosp N Durham, Dept Med Phys & Gen Surg, Durham DH1 5TW, England
来源
关键词
COLORECTAL SURGERY; COMPLICATIONS; SMOKING; BLOOD; COLON; FLOW;
D O I
10.1007/978-1-4419-1241-1_39
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aims of this study were to determine the normal range of tissue oxygenation (SO2) in the "mature" colostomy stoma and to investigate whether there were any diurnal variations in the SO2 values. Ten patients with an end colostomy for a minimum duration of three months and using conventional colostomy bags were included in this study. Tissue SO2 was measured on the stoma using visible wavelength spectroscopy (Whit land RM 200, Whit land Research, Whit land, UK) The measurements were carried out on each patient on three occasions: the first early in the morning (designated "baseline"), a second after 6 h and the third on the next day at 24 h. The results showed that the mean baseline SO2 in the colostomy stoma was 77.6 +/- 6.8 and there were no differences in the SO2 measurements between the baseline, 6 h and the 24 h values. There were also no differences in the SO2 values between the four quadrants of the stomas. In conclusion, visible wavelength spectrophotometry can reliably measure stomal SO2 in a non-invasive way. No significant diurnal variations in the stomal SO2 values were detected.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 50 条
  • [31] ON THE USE OF UV SPECTROPHOTOMETRY TO ASSESS DISSOLVED ORGANIC-CARBON ORIGIN VARIATIONS IN THE UPPER RHONE RIVER
    ROSTAN, JC
    CELLOT, B
    AQUATIC SCIENCES, 1995, 57 (01) : 70 - 80
  • [32] Non-invasive technique to assess hepatic tissue oxygenation using near-infrared spectroscopy
    El-Desoky, A
    Seifalian, AM
    Davidson, BR
    BRITISH JOURNAL OF SURGERY, 1998, 85 (05) : 701 - 701
  • [33] Use of ultraviolet–visible spectrophotometry associated with artificial neural networks as an alternative for determining the water quality index
    Edson Marcelino Alves
    Ramon Juliano Rodrigues
    Caroline dos Santos Corrêa
    Tiago Fidemann
    José Celso Rocha
    José Leonel Lemos Buzzo
    Pedro de Oliva Neto
    Eutimio Gustavo Fernández Núñez
    Environmental Monitoring and Assessment, 2018, 190
  • [34] USE OF FOOD DYES AS TRACERS TO MEASURE MULTIPLE SPRAY DEPOSITS BY ULTRAVIOLET-VISIBLE ABSORPTION SPECTROPHOTOMETRY
    Sanchez-Hermosilla, J.
    Medina, R.
    Rodriguez, F.
    Callejon-Ferre, Angel J.
    TRANSACTIONS OF THE ASABE, 2008, 51 (04) : 1177 - 1186
  • [35] THE USE OF ULTRAVIOLET-VISIBLE SPECTROPHOTOMETRY IN THE DETERMINATION OF AVERAGE PROPERTIES OF NONYLPHENOL ETHYLENE-OXIDE CONDENSATES
    DELAGUARDIA, M
    CARRION, JL
    MEDINA, J
    ANALYTICA CHIMICA ACTA, 1983, 155 (DEC) : 113 - 121
  • [36] USE OF VISIBLE NEAR-INFRARED SPECTROPHOTOMETRY FOR THE STUDY OF THE EFFECT OF ANTIOXIDANTS ON THE STABILITY OF BETA-CAROTENE
    BERSET, C
    MARTY, C
    AGRICULTURE, FOOD CHEMISTRY AND THE CONSUMER, VOLS 1 AND 2: THE CONSUMER AND FOOD, ANALYTICAL FOOD CHEMISTRY AND AGRICULTURAL PRODUCTION, BIOTECHNOLOGY AND BIOASSAYS - IMPACT OF TECHNOLOGY ON FOOD QUALITY, FOOD CHEMISTRY AND QUALITY ASSURANCE, 1989, : 427 - 432
  • [37] Use of a simple intraoperative hydrostatic pressure test to assess the relationship between mobility of the ventricular stoma and success of third ventriculostomy
    Kamel, MH
    Kelleher, M
    Aquilina, K
    Lim, C
    Caird, J
    Kaar, G
    JOURNAL OF NEUROSURGERY, 2005, 103 (05) : 848 - 852
  • [38] Tissue oxygen saturation measured by near infrared spectrophotometry correlates with arterial oxygen saturation during induced oxygenation changes in neonates
    Wolf, M
    von Siebenthal, K
    Keel, M
    Dietz, V
    Baenziger, O
    Bucher, HU
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (04) : 481 - 491
  • [39] Use of the liver tissue oxygenation index as a noninvasive parameter of intestinal ischemia in rabbits
    Vanderhaegen, J.
    Dehing, L.
    Naulaers, G.
    Devlieger, H.
    Al-Olayet, Y.
    Penninckx, F.
    Miserez, M.
    WORLD JOURNAL OF SURGERY, 2007, 31 (12) : 2359 - 2362
  • [40] Use of a tissue microarray to assess the accuracy of lymphoma classification by needle biopsy
    Farmer, PL
    Virk, SU
    Burns, BF
    LeBrun, DP
    BLOOD, 2005, 106 (11) : 295A - 295A